SAFETY REVERSING SENSOR REPLACEMENT
041-0136 & 041-0155
BesurepowerisNOT connected to thegaragedooropenerBEFORE installing the
safetyreversing sensor.
TopreventSERIOUSINJURYorDEATHfromclosing garagedoor:
•Correctlyconnectand align thesafetyreversing sensor.Thisrequired safety
deviceMUSTNOT bedisabled.
•Install thesafetyreversing sensorsobeam isNOHIGHERthan 6"(15 cm)
abovegarage floor.
WARNING: Thisproduct canexposeyou to chemicalsincluding lead,whichare
known to the StateofCaliforniato causecancerorbirth defectsorother
reproductiveharm. Formoreinformation go towww.P65Warnings.ca.gov
Theimages throughoutthismanualare for reference only andyour product may look
different.
INSTALL THE SAFETY REVERSING SENSORS
Disconnectpowertothe garage dooropenerbeforeyou begin.
The safetyreversing sensorsaredesignedtoclip onto thedoortrackwith theprovided
sensorbrackets.Ifthedoortrackwill notsupportthesensorbracketawall installation is
recommended.The sensorbeam should be NOHIGHERthan 6"(15 cm)abovethefloor.
DOOR TRACKINSTALLATION
1.Slide the curvedarms ofthe sensor bracket aroundthe edgeofthe doortrack.
Snap into placesothatthesensorbracketisflush againstthetrack.
2.Slide the hex screwthroughthesensor.
3.Attach thesensortothe bracketwith thewing nut. Makesurethelensisnot
obstructed bythebracket.
Repeatthesteps with theothersensoron theoppositedoortrack.Both lensesmust
faceeach other.
6" (15 cm) max.
Door track
1
2 3
Garage door
Wing nut
WALL OPTION
Make sure thebrackets oneachsideare clearofthedoor track andhave the same
amount ofclearancesothesensorswill align correctly.Ifadditionalclearanceisneeded,
useextension brackets041A5281-1 (not provided)orwood blocks.
1.Attach thesensorbracketagainst thewall with two lagscrews(not provided).
2.Slide the hex screwthroughthesensor.
3.Attach thesensortothe bracketwith thewing nut. Makesurethelensisnot
obstructed bythebracket.
Repeat the stepswiththeothersensor onthe opposite side ofthegarage door. Both
lensesmust faceeach other.
OR
1
Wing Nut
OPTIONAL
2 3
Door track
Inside
garage wall
6" (15 cm)
max.
Not provided
FLOOR OPTION
1.Measure the positionofbothsensor brackets sothey willbe the samedistance
from thewallandunobstructed.
2.Attachthe brackettothefloorwithconcrete anchors (notprovided).
3.Slide the hex screwthroughthesensor.
4.Attach thesensortothe bracketwith thewing nut. Makesurethelensisnot
obstructed bythebracket.
Repeat the stepswiththeothersensor onthe opposite side ofthegarage door. Both
lensesmust faceeach other.
1
3 4
2
Inside
garage wall
Not provided
Door track
6" (15 cm) max.
Wingnut
Product specificaties
| Merk: | Chamberlain |
| Categorie: | Niet gecategoriseerd |
| Model: | 041-0136 |
Heb je hulp nodig?
Als je hulp nodig hebt met Chamberlain 041-0136 stel dan hieronder een vraag en andere gebruikers zullen je antwoorden
Handleiding Niet gecategoriseerd Chamberlain
Chamberlain 041-0190-000 Handleiding Chamberlain KLIK2U-P2 Handleiding Chamberlain KLIK2C-P2 Handleiding Chamberlain 041A5034 Handleiding Chamberlain 801CB-P Handleiding Chamberlain 041A6262 Handleiding Chamberlain MYQ-G0402 Handleiding Chamberlain T3EML Handleiding