Please read and save these instructions. Read carefully before attempting to assemble, install, operate or maintain the product described.
Protect yourself and others by observing all safety information. Failure to comply with instructions could result in personal injury and/or prop-
erty damage! Retain instructions for future reference.
Safety Guidelines
This manual contains information that is
very important to know and understand.
This information is provided for SAFETY
and to PREVENTEQUIPMENTPROB-
LEMS. To help recognize this informa-
tion, observe the following symbols.
Danger indicates
an imminently haz-
ardous situation which, if not avoided,
WILL result in death or serious injury.
Warning indicates
a potentially haz-
ardous situation which, if not avoided,
COULD result in death or serious injury.
Caution indicates a
potentially haz-
ardous situation which, if not avoided,
MAY result in minor or moderate injury.
Notice indicates
important informa-
tion that, if not followed, may cause
damage to equipment.
Unpacking
After unpacking the unit, inspect care-
fully for any damage that may have
occurred during transit. Make sure to
tighten fittings, bolts, etc., before
putting unit into service.
Do not operate
unit if damaged
during shipping, handling or use.
Damage may result in bursting and
cause injury or property damage.
General Safety Information
Since the air compressor and other
components (material pump, spray
guns, filters, lubricators, hoses, etc.)
used make up a high pressure pumping
system, the following safety precau-
tions must be observed at all times:
!
NOTICE
Operating Instructions
Breathable Air Warning
This compressor/pump is not
equipped and should not be used
“as is” to supply breathing quality
air. For any application of air for
human consumption, the air com-
pressor/pump will need to be fitted
with suitable in-line safety and
alarm equipment. This additional
equipment is necessary to properly
filter and purify the air to meet
minimal specifications for Grade D
breathing as described in
Compressed Gas Association
Commodity Specification for air,
OSHA, ANSI and/or Canadian
Standards Associations (CSA).
DISCLAIMER OF WARRANTIES
In the event the compressor is used
for the purpose of breathing air
application and proper in-line safe-
ty and alarm equipment is not
simultaneously used, existing war-
ranties shall be voided, and
Campbell Hausfeld disclaims any
liability whatsoever for any loss,
personal injury or damage.
1.
Read all manuals
included with this
product carefully. Be
thoroughly familiar
with the controls and
the proper use of the equipment.
2.Follow all local electrical and safety
codes as well as in the United
States, the National Electrical Codes
(NEC) and Occupational Safety and
Health Act (OSHA).
3.
Only persons well acquainted with
these rules of safe operation should
be allowed to use the compressor.
4.Keep visitors away and NEVER
allow children in the work area.
5.
Wear safety glasses and use hearing
protection when operating the unit.
6.Do not stand on or use the unit as a
handhold.
7.Before each use, inspect com-
pressed air system and electrical
components for signs of damage,
deterioration, weakness or leakage.
Repair or replace defective items
before using.
8. Check all fasteners at frequent
intervals for proper tightness.
Motors, electrical equip-
ment and controls can
cause electrical arcs that
will ignite a flammable gas or vapor.
Never operate or repair in or near a
flammable gas or vapor. Never store
flammable liquids or gases in the vicin-
ity of the compressor.
Never operate compres-
sor without guards. This
unit can start automati-
cally without warning.
IN755201AV 11/99
Personal injury or property damage
could occur from contact with moving
parts.
9.Do not wear loose clothing or jewel-
ry that will get caught in the mov-
ing parts of the unit.
Compressor parts may
be hot even if the unit
is stopped.
MANUAL
BUILT TO LAST
TM
Dental Air
Series
2
Operating Instructions
General Safety Information
(Continued)
10.Keep fingers away from a running
compressor; fast moving and hot
parts will cause injury and/or burns.
11.If the equipment should start to
vibrate abnormally, STOP the unit
and check immediately for the
cause. Vibration is generally a warn-
ing of trouble.
12.To reduce fire hazard, keep unit
exterior free of oil, solvent, or exces-
sive grease.
An ASME code safe-
ty relief valve with
a setting no higher than the tank maxi-
mum allowable working pressure MUST
be installed in the air lines or in the
tank for this compressor. The ASME
safety valve must have sufficient flow
and pressure ratings to protect the
pressurized components from bursting.
The flow rating can be found in the
parts manual.
Do not operate
with pressure
switch or pilot valves set higher than
the tank maximum allowable working
pressure.
13.Never attempt to adjust ASME safe-
ty valve. Keep safety valve free from
paint and other accumulations.
Never attempt to repair
or modify a tank!
Welding, drilling or any
other modification will
weaken the tank resulting in damage
from rupture or explosion. Always
replace worn, cracked or damaged tanks.
Drain liquid from
tank daily.
!
NOTICE
14.
Tanks rust from moisture build-up,
which weakens the tank. Make sure
to drain tank regularly and inspect
periodically for unsafe conditions
such as rust formation and corrosion
.
15.Fast moving air will stir up dust and
debris which may be harmful. Release
air slowly when draining moisture or
depressurizing the compressor system.
Installation
Disconnect, tag and
lock out power source
then release all pres-
sure from the system
before attempting to install, service,
relocate or perform any maintenance.
Do not lift or move
unit without
appropriately rated equipment. Be sure
the unit is securely attached to lifting
device used. Do not lift unit by holding
onto tubes or coolers. Do not use unit
to lift other attached equipment.
Never use the
wood shipping
skids for mounting the compressor.
Install and operate unit at least 24”
from any obstructions in a clean, well
ventilated area. The surrounding air
temperature should not exceed 104
o
F.
This will ensure an unobstructed flow
of air to cool compressor and allow
adequate space for maintenance.
Do not locate the
compressor air inlet
near steam, paint spray, sandblast areas
or any other source of contamination.
NOTE: If compressor operates in a hot,
moist environment, supply compressor
pump with clean, dry outside air.
Supply air should be piped in from
external sources.
TANK MOUNTING
The tank should be bolted on a flat,
even, concrete floor or on a separate
concrete foundation. Vibration isola-
tors should be used between the tank
leg and the floor. When using isolator
pads, do not draw bolts tight. Allow
the pads to absorb vibrations. When
isolators are used, a flexible hose or
coupling should be installed between
the tank and service piping.
Failure to properly
install the tank can
lead to cracks at the
welded joints and pos-
sible bursting.
PIPING
Never use plastic
(PVC) pipe for com-
pressed air. Serious injury or death
could result.
Any tube, pipe or hose connected to the
unit must be able to withstand the tem-
perature generated and retain the pres-
sure. All pressurized components of the
air system must have a pressure rating
higher than or equal to the ASME safety
valve setting. Incorrect selection and
installation of any tube, pipe or hose
could result in bursting and injury.
MINIMUM PIPE SIZE
FOR COMPRESSED AIR LINE
Length Of Piping System
CFM25’50’100’250’
101/2”1/2”1/2”3/4”
203/43/43/41
403/4111
603/4111
1001111
1
/
4
Dental Air Series
3
grounding wire with an appropriate
grounding plug. Plug must be plugged
into an outlet that is properly installed
and grounded in accordance with all
local codes and ordinances.
Do not use
grounding
adapter. Improper use of grounding
plug adapter can result in a possible
risk of electrical shock!
2.If repair or replacement of cord or
plug is necessary, do not connect
grounding wire to either flat blade
terminal. The wire with insulation
having an outlet surface that is green
with or without yellow stripes is the
grounding wire.
3.Check with a qualified electrician or
serviceman if grounding instructions
are not completely understood, or if
in doubt as to whether product is
properly grounded. Do not modify
General Safety Information
(Continued)
INSTALLING A SHUT-OFF VALVE
A shut-off valve should be installed on
the discharge port of the tank to con-
trol the air flow out of the tank. The
valve should be located between the
tank and the piping system.
Never install a
shut-off valve
between the compressor pump and the
tank without an appropriate safety
valve. Personal injury and/or equip-
ment damage may occur. Never use
reducers in discharge piping.
When creating a permanently installed
system to distribute compressed air,
find the total length of the system and
select pipe size from the chart. Bury
underground lines below the frost line
and avoid pockets where condensation
can gather and freeze.
Apply air pressure to the piping installa-
tion and make sure all joints are free
from leaks BEFORE underground lines are
covered. Before putting the compressor
into service, find and repair all leaks in
the piping, fittings and connections
.
Operation
WIRING
1.Local electrical wiring codes differ
from area to area. Source wiring, plug
and protector must be rated for at
least the amperage and voltage indi-
cated on motor nameplate, and meet
all electrical codes for this minimum .
2.Use a slow blow fuse type T or a cir-
cuit breaker.
Overheating, short
circuiting and fire
damage will result from inadequate
wiring, etc.
NOTE: 120 volt, 10 and 13 amp units
can be operated on a 115 volt, 15 amp
circuit under the following conditions:
a.No other electrical appliances or
lights are connected to the same
branch circuit.
b.Voltage supply is normal.
c.Extension cords are of the minimum
gauge specified in this instruction
manual.
d.Circuit is equipped with a 15 amp cir-
cuit breaker or a 15 amp slow blow
fuse type T.
3.If above conditions cannot be met or
if nuisance tripping of current pro-
tection device occurs, it may be nec-
essary to operate compressor from a
115 volt, 20 amp circuit.
GROUNDING INSTRUCTIONS
1.This product should be grounded. In
the event of an electrical short circuit,
grounding reduces risk of electrical
shock by providing an escape wire for
electric current. This product is
equipped with a cord having a
TEST
RESET
Figure 1 - Grounding Method
Power cordWhiteLineNo
Motor cordWhiteLoadNo
Power cordBlackLineYes
Motor cordBlackLoadYes
(✽) When the unit is not in operation
✽ Wire and Terminal Guide
WireColorTerminalHot
Gauge of Cord141010866442
Extension cords for 120V/15 Amp Unit
Length of Cord (ft)2550100150200250300400500
Table 2
Table 1
Operating Instructions
WTS Models
Grounded
Outlet
Grounding
Pin

Beoordeel deze handleiding


Product specificaties

Merk: Campbell Hausfeld
Categorie: Compressor
Model: WTS115802

Heb je hulp nodig?

Als je hulp nodig hebt met Campbell Hausfeld WTS115802 stel dan hieronder een vraag en andere gebruikers zullen je antwoorden