Instruction Manual
Manuel d’instructions
Manual de instrucciones
Electric Single–Stage Air Compressor
Compresseurs d’air électriques à étapes
Compresores de aire eléctricos de etapas
E118903
XXX80i15175AAA
11/01/2025
WARNING:
Read and understand all safety precautions in this manual before operating. Failure to comply with instructions in
this manual could result in personal injury, property damage, and/or voiding of your warranty. The manufacturer WILL NOT be liable
for any damage because of failure to follow these instructions. Retain this manual for future reference.
AVERTISSEMENT:
Lire et s’assurer de bien comprendre toutes les consignes de sécurité du présent manuel avant
d’utiliser l’outil. Toute dérogation aux instructions contenues dans ce manuel peut entraîner l’annulation de la garantie, causer des
blessures et/ou des dommages matériels. Le fabricant NE SAURA être tenu responsable de dommages résultant de l’inobservation
de ces instructions.
ADVERTENCIA:
Lea y comprenda todas las precauciones de seguridad contenidas en este manual antes de utilizar esta
herramienta. El no cumplir con las instrucciones de este manual podría dar como resultado la anulación de su garantía, lesiones
personales y/o daños a la propiedad. El fabricante NO SERA responsable de cualquier daño debido a no acatar estas instrucciones.
2 - ENG
E118903
SAFETY GUIDELINES ..........................................................2-4
OVERVIEW ..............................................................................4
GLOSSARY OF TERMS ..........................................................5
ASSEMBLY ..............................................................................5
TYPICAL INSTALLATION ........................................................6
COMPRESSOR CONTROLS ...................................................7
ELECTRICAL POWER REQUIREMENTS ...............................8
OPERATING INSTRUCTIONS ................................................9
MAINTENANCE ................................................................10-12
SERVICE INTERVAL .............................................................12
TROUBLESHOOTING CHART ..............................................13
WARRANTY ...........................................................................14
TABLE OF CONTENTS
SAFETY GUIDELINES
IMPORTANT SAFETY INSTRUCTIONS
The following information relates to protecting YOUR SAFETY and PREVENTING EQUIPMENT PROBLEMS. To help you recognize
this information, we use the following symbols. Please read the manual and pay attention to these sections.
– Indicates an imminently hazardous situation which, if not avoided, will result in death or serious injury.
– Indicates a potentially hazardous situation which, if not avoided, could result in death or serious injury.
– Indicates a potentially hazardous situation which, if not avoided, may result in minor or moderate injury.
WARNING triangle (Used without word) indicates a safety related message.
– Indicates a practice not related to personal injury which, if not avoided, may result in property damage.
WARNING:
DANGER:
CAUTION:
RISK OF FIRE OR EXPLOSION Never spray flammable liquids in a confined area. It is normal for the motor and pressure switch
to produce sparks while operating. If sparks come into contact with vapors from gasoline or other
solvents, they may ignite, causing fire or explosion. Always operate the compressor in a well–
ventilated area. Do not smoke while spraying. Do not spray where sparks or flame are present.
Keep compressor as far from spray area as possible. Store flammable materials in a secure
location away from compressor. Equip the area of operation with a fire extinguisher.
RISK OF BURSTING
Do not weld, drill or modify the air tank of this compressor. Welding or modifications on the air
compressor tank can severely impair tank strength and cause an extremely hazardous condition.
Welding or modifying the tank in any manner will void the warranty. If tank develops a leak, replace
it immediately with a new tank or replace the entire compressor.
RISK OF ELECTRICAL SHOCK
Never use an electric air compressor outdoors when it is raining or on a wet surface, as it may
cause an electric shock. Failure to provide adequate grounding to this product could result in
serious injury or death from electrocution. Make certain that the electrical circuit to which the
compressor is connected provides proper electrical grounding, correct voltage and adequate fuse
protection.
RISK OF BURSTING
Check the manufacturer’s maximum pressure rating for air tools and accessories. Compressor
outlet pressure must be regulated so as to never exceed the maximum pressure rating of the
tool. Relieve all pressure through the hose before attaching or removing accessories. Never use
compressor to inflate small low pressure objects such as children’s toys, footballs, basketballs, etc.
RISK TO BREATHING/
INHALATION HAZARD
Always wear MSHA/NIOSH approved, properly fitting face mask or respirator and work
in a well ventilated area when using tools that generate dust. Some dust created by power
sanding, grinding, drilling and other construction activities contains chemicals known (to the State
of California) to cause cancer, birth defects or other reproductive harm. Some examples of these
chemicals are:
• lead from lead-based paints
• crystalline silica from bricks and cement and other masonry products
• arsenic and chromium from chemically treated lumber.
RISK TO BREATHINGBe certain to read all labels when you are spraying paints or toxic materials, and follow the safety
instructions provided on the label or safety sheets for the materials you are spraying. Use a MSHA/
NIOSH approved respirator mask if there is a chance of inhaling anything you are spraying. Read
all instructions and be sure that your respirator mask will protect you. Work in an area with good
cross ventilation.
NOTICE
DANGER:
3 - ENG
E118903
RISK OF BURSTING•Do not adjust the tank safety valve for any reason. Doing so voids all warranties. The safety valve
has been pre-set at the factory for the maximum pressure of this unit. Personal injury and /or
property damage may result if the relief valve is tampered with.
•Do not use polymeric pipe not safety certified and not marked for use with compressed air
Conventional plastic or PVC pipe is not designed for use with compressed air regardless of its
marked pressure rating.
•Drain the moisture from the tank on a daily basis. A clean, dry tank will help prevent corrosion.
•Pull the tank safety valve ring daily to ensure that the valve is functioning properly, and to clear the
valve of any possible obstructions.
RISK OF FIRE
Unattended operation of this compressor could result in personal injury or property damage. To
reduce the risk of fire, do not allow the compressor to operate unattended. Always disconnect
electrical power by turning the pressure switch to off and drain the tank daily or after each use.
RISK TO BREATHING
(ASPHYXIATION)
Air obtained directly from the compressor should never be used to supply air for human
consumption. The air stream may contain carbon monoxide, toxic vapors, or solid particles from
tank. Breathing these contaminant’s can cause serious injury or death. In order to use air produced
by this compressor for breathing, suitable filters and in-line safety equipment must be properly
installed. In-line filters and safety equipment must be properly installed. In-line filters and safety
equipment used in conjunction with the compressor must be capable of treating air to all applicable
local and federal codes prior to human consumption.
RISK OF UNSAFE OPERATION
Always operate the compressor in a stable secure position to prevent accidental movement of the
unit.
RISK OF ELECTRICAL SHOCK
Refer to the motor’s nameplate label for voltage and amperage requirements. Ensure that all wiring
is done by a licensed electrician, in accordance with the National Electrical code.
RISK OF BURSTING
Regardless of size or manufacturer, the practical service life of an air compressor tank utilized on an
air compressor or as an additional capacity air storage tank is influenced by many variables which
include but are not limited to the frequency and adherence to operator maintenance guidelines,
regularity of service, environmental conditions, and duty cycle. These factors can impact the overall
life expectancy of the air compressor tank. Therefore, it is strongly advised that the air compressor
tank SHOULD RECEIVE REGULAR INSPECTIONS in accordance with the National Board
Inspection Code (NBIC). For more information about the NBIC or to locate an authorized inspection
agency for your jurisdiction, please refer to the website (www.nationalboard.org).
RISK OF FIRETo provide proper ventilation for cooling, the compressor must be kept a minimum of 12” (30
cm) from the nearest wall, in a well–ventilated area. Restricting any of the compressor ventilation
openings will cause overheating and could cause fire, never place objects against or on top of
compressor.
RISK OF ELECTRICAL SHOCK
OR INJURY
Use indoors only.
RISK OF BURSTING
Check the manufacturer’s maximum pressure rating for air tools and accessories. Compressor
outlet pressure must be regulated so as to never exceed the maximum pressure rating of the
tool. Relieve all pressure through the hose before attaching or removing accessories. Never use
compressor to inflate small low pressure objects such as children’s toys, footballs, basketballs, etc.
RISK OF BURSTING
To prevent damage to tank and compressor on stationary models, the tank must be shimmed so
the pump base is level within 1/8” to distribute oil properly. All feet must be supported, shimming
where necessary, prior to attaching to the floor. Fasten all feet to floor. We also recommend the use
of vibration pads (E110586) under tank feet.
RISK OF FIRE
On oil-lubed compressors, oil can leak or spill and could result in fire or breathing hazard. Oil leaks
will damage paint, carpet or other surfaces in vehicles or trailers. Always place the compressor
on a protective mat when transporting to protect against damage to vehicle from leaks. Remove
compressor from vehicle immediately upon arrival at your destination.