Braun Age Precision PRT 2000 Handleiding

Braun Thermometer Age Precision PRT 2000

Bekijk gratis de handleiding van Braun Age Precision PRT 2000 (4 pagina’s), behorend tot de categorie Thermometer. Deze gids werd als nuttig beoordeeld door 115 mensen en kreeg gemiddeld 4.0 sterren uit 7 reviews. Heb je een vraag over Braun Age Precision PRT 2000 of wil je andere gebruikers van dit product iets vragen? Stel een vraag

Pagina 1/4
English
Description
1. Measuring sensor 5. Large display with colour-coded indicator lights
2. Extra gentle exible tip 6. Battery compartment cover (back)
3. On/O button (side) 7. Protective cap
4. Age Precision™ button
Warnings and Precautions
•YourBraunDigitalThermometerisa3-in-1thermometersuitableforunderarm,oralorrectaluse.
Whichevermethodisused,itisrecommendedthatfor15minutespriortouse,avoideatingordrinking
anyliquids,exercising,takingshowersorbaths,orsmoking.
•Thisthermometerisintendedforhouseholduseonly.Thisproductisnotintendedtodiagnoseany
disease,butisausefulscreeningtoolfortemperature.Useofthisthermometerisnotintendedasa
substituteforconsultationwithyourphysician.
•TheAgePrecision™featureisnotintendedforpre-termbabiesorsmall-for-gestationalagebabies.The
AgePrecision™featureisnotintendedtointerprethypothermictemperatures.
•Pleaseconsultyourphysicianifthethermometershowselevatedtemperature.High,prolongedfever
requiresmedicalattention,especiallyforyoungchildren.
•Parents/guardiansshouldcallthephysicianuponnoticinganyuntowardsign(s)orsymptom(s).For
example,achildwhoexhibitsirritability,vomiting,diarrhea,dehydration,changesinappetiteor
activity,evenintheabsenceoffever,orwhoexhibitsalowtemperature,maystillneedtoreceive
medicalattention.Childrenwhoareonantibiotics,analgesics,orantipyreticsshouldnotbeassessed
solelyontemperaturereadingstodeterminetheseverityoftheirillness.
•TemperatureelevationasindicatedbyAgePrecision™maysignalaseriousillness,especiallyin
neonatesandinfants,oradultswhoareold,frail,haveaweakenedimmunesystem.Pleaseseek
professionaladviceimmediatelywhenthereisatemperatureelevationandifyouaretaking
temperaturefor:
-Neonatesandinfantsunder3months.Consultyourphysicianimmediatelyifthetemperature
exceeds37.4°Cor99.4°F.
-Patientsover60yearsofage.Fevermaybebluntedorabsentinelderlypatients.
- Patients having diabetes mellitus or a weakened immune system
(e.g.HIVpositive,cancerchemotherapy,chronicsteroidtreatment,splenectomy).
- Patients who are bedridden
(e.g.nursinghomepatient,stroke,chronicillness,recoveringfromsurgery).
-Atransplantpatient(e.g.liver,heart,lung,kidney).
•Donotallowchildrenunder12yearsofagetotaketheirtemperaturesunattended.
•Donotallowchildrentowalkorrunduringtemperaturetaking.
•Thisthermometercontainssmallpartsthatcanbeswallowedorproduceachokinghazardtochildren.
Alwayskeepthethermometeroutofchildren’sreach.
•Donotmodifythisequipmentwithoutauthorizationofthemanufacturer.
•ManufacturingdateisgivenbytheLOTnumberlocatedatthebackofthethermometer.Therstthree
(3)digitsrepresenttheJuliandatethattheproductwasmanufactured,andthenexttwo(2)digits
representthelasttwonumbersofthecalendaryeartheproductwasmanufactured.Thelastidentiers
arethelettersthatrepresentthemanufacturer.
•Anexample:LOT:11614FAMimpliesthisproducthasbeenmanufacturedonthe116thdayofthe
year 2014.
What is new about Braun Age Precision™ Thermometer?
•Clinicalresearchshowsthedenitionoffeverchangeswithage1.Forexample,whatisanormal
bodytemperatureina4yearold,mayberegardedasafeverinanewborn.Braun’sAgePrecision™
thermometerisanageadjustablethermometerwithapatentedFeverInsight®colour-codeddisplay.
Itusesmedicalguidelinestointerprettemperatureandtakestheguessworkoutofinterpreting
temperaturefortheentirefamily.
•Temperaturereadingsvarydependingonthesiteofmeasurement.Anoraltemperatureisgenerally
0.1°C higher than underarm (axillary) temperature and rectal temperature is generally 0.6°C higher than
underarm temperature.1,2
Braun’s Age Precision™ feature is optimized for underarm temperature taking.
•Temperaturereadingsvaryfrompersontoperson.Thebestmethodtodetermineyourownnormal
temperatureistousethethermometerwhenyouarefeelingwell.Recordyourreadingtwiceaday
(earlymorningandlateafternoon).Taketheaverageofthetwotemperatures.Thisisconsideredyour
normalbodytemperature.Anyvariationfromitmayindicatesomesortofillnessandyoushould
consult your physician.
Itisimportanttorememberfeverisasymptom,notadisease,andisjustoneofthemanypossiblesignsof
illness.Ifyourchildexhibitssignsofaseriousillness,contactyourphysician
How to Use Your Braun Age Precision™ Thermometer
3 Simple Steps:
1. Switch on the thermometer by pressing the On/O button
Youwillhearashortbeepanddisplaysegmentcheckwillbeperformed.Afterthesegmentcheck,last
temperaturereadingwillbedisplayedfor2seconds.Subsequently,theageiconsandagerangewill
cycle,untiltheAgePrecisionbuttonispressed.
2. Select the age by pressing the AgePrecision™ button
WhentheAgePrecision™buttonispressed,theagerangeiconswillstopcycling,andstopontheage
range icon that was showing when the button was pressed. Keep pressing the button until the desired
agesettingisdisplayed.Thethermometerhas3agesettings:
•0-3months
•3-36months
•36monthsuptoanadult
Aftertheageisselected,theagerangeiconremainssteadilylit.
Thedisplaywillshowthreedashedlinesandthethermometer
is ready to start the measurement.
3. Take the measurement by placing it on the measurement site.
Oncetemperatureriseisdetectedbythermometerinmeasurementmode,itwillbegintomeasure.
Ifthethermometerdoesn’tmeasureatemperaturerise,theageiconandthreedashedlineswillbe
shown until the thermometer automatically turns o.
Aftermeasurement(generally8secondsaftertemperaturechangeisdetected),theconrmation
beepindicatesthatanaccuratetemperaturemeasurementhasbeentaken:1longbeepfornormal
temperature,10shortbeepsforelevatedandhightemperature.Theresultwillbeshownonthe
display.InterpretthereadingwiththehelpofthecolourcodedFeverInSight®displaythatusesmedical
guidelinestointerprettemperaturebasedontheageofthepatients.
Note:Usershavetoshutdownthethermometerandstartupagaintotakeanothermeasurementand/or
changeagesetting.TheBraunAgePrecision™thermometerturnsoautomatically
20secondsafterthemeasurementorafter90secondswithoutmeasurement.
Reading the measurement with Fever InSight® Colour Coded Display
BraunAgePrecision™ThermometercomeswiththepatentedFeverInSight®displaythatoersacolour
indication along with the temperature readout and helps you better understand the temperature reading
basedonpatients’age.
- Green backlight indicates readingnormal
-Yellowbacklightindicateselevated temperature
-Redbacklightindicateshigh temperature
TheFeverInSight®colourcodeddisplayforinterpretingfeverhasbeendesignedforuseintheunderarm
mode only according to the table below.
SiteAge rangeGreen
Normal temperature
Yellow
Elevated temperature
Red
Hightemperature
Underarm
0-3 Months35.7 – 37.3 °C> 37.3 °C
3-36 Months35.3 – 37.4 °C37.5–38.4°C >38.4°C
36 Months-
adult 35.3 – 37.4 °C37.5 – 39.4 °C> 39.4 °C
Ifyouusethethermometerintheoralorrectalmodebyplacingitatthosesites,pleasedonotusethe
displaylightsprogrammedintothethermometerfordeterminingfever.Instead,refertotheoralandrectal
tablesrespectivelyasshownbelowtodetermineifyouhaveafever.
SiteAge range Normal temperatureElevated temperatureHigh temperature
Oral
0-3 Months35.8–37.4°C> 37.4 °C
3-36 Months35.4 – 37.6 °C37.7–38.5°C >38.5°C
36 Months
to Adult35.4 – 37.7 °C> 39.4 °C37.8-39.4°C
Rectal
0-3 Months36.3 – 37.9 °C> 37.9 °C
3-36 Months 35.9–38.1°C38.2–39.0°C> 39.0 °C
36 Months-
adult 35.9–38.2°C38.3–39.9°C> 39.9 °C
Note:Duetohumanphysiology,temperaturemeasurementstakenfromdierentsitesonthesame
personshowvariability.Forexample,rectalreadingstendtorunhigherthanoralaswellasunderarm
readingstakenfromthesameperson.
Tips for Measuring at Dierent Sites
Under-the-arm (axillary) use
Thismethodisusedforbabiesandyoungchildren.
1. Wipe the underarm with a dry towel.
2.Placetheprobetipunderthearmsothetipistouchingtheskinandpositionthepatient’sarmnextto
thepatient’sbody(Fig.1).
Withayoungchild,itissometimeshelpfultohugthechildtokeeptheirarmnexttotheirbody.This
ensures that the room air does not aect the reading.
3.Whenthepeaktemperatureisreached,beepsignalswillsound.Thetemperatureisnowconrmed.
Whenthethermometerisremovedfromthemeasuringsite,associatedFeverInsight™colourwilldisplay.
4.Turnothethermometerandcleanasrecommendedbelow.
Fig.1Fig.2
Oral use
Thismethodissuitableforchildrenwhoareoldenoughtosafelykeepthethermometerinsidethemouth.
1.Itisimportanttoplacethetipofthethermometerwellunderthetongueoneithersidetogetagood,
accuratereading.Placesensortipinareasmarkedwith“√”underthetongue(Fig.2).Keeppatient’s
mouth closed and make him/her sit still to help ensure an accurate measurement.
2.Whenthepeaktemperatureisreached,beepsignalswillsound.Thetemperatureisnowconrmed.
Whenthethermometerisremovedfromthemeasuringsite,associatedFeverInsight™colourwilldisplay.
3.Turnothethermometerandcleanasrecommendedbelow.
Rectal use
Commonlyusedforbabies,youngchildren,orwhenitisdiculttotakeanoralorunderarmtemperature.
1.Coverthethermometer’stipwithaprobecoverandlubricatewithawater-solublejellyforeasier
insertion.
Donotuseapetroleumjelly.Readthelabelofthelubricanttobesureyouareusingtherightkind.
2.Laythepatientonhis/herside.Ifthepatientisaninfant,theproperpositionforababyistolayonits
stomachwithlegshangingdown,eitheracrossyourkneesorattheedgeofabedorchangingtable.
Thispositionstheinfant’srectumforsafeandeasyinsertionofthethermometer.
3.Gentlyinsertthetipofthethermometer 1.3cmor1/2inchintotherectum.IfyouNO MORE THAN
detectresistance,stop.Holdthethermometerinplaceduringmeasurement.
4.Whenthepeaktemperatureisreached,beepsignalswillsound.Thetemperatureisnowconrmed.
Whenthethermometerisremovedfromthemeasuringsite,associatedFeverInsight™colourwilldisplay.
5.Turnothethermometerandcleanasrecommendedbelow.
Memory
Whenthethermometeristurnedon,thedisplaywillshowatest,afterwhichthelastmeasured
temperaturewillbeshownforapproximately1second.Letter“M”willbedisplayednexttothe
temperature reading.
Changing the Temperature Scale
Withpowero,pressandholdtheOn/Obuttonforabout5secondsuntil“---“withasteady“°C”or
“°F”appearsonscreen.ReleaseandpresstheOn/Obuttonagaintoswitchfromthecurrentscaletothe
alternatescaleandrelease.Afterabout3secondstheunitisreadyfortakingtemperatureinthechosen
scale and the age range icons start to scroll.
Care and Cleaning
•Cleantheprobetipbywashingwithsoapandwarmwaterorbydisinfectingwithrubbingalcohol(70%
isopropyl alcohol).
•Wipedrywithsoftcloth.
•DO NOT BOIL OR CLEAN IN DISHWASHER.Thiswillcausethethermometertonolongerfunctionand
will void the warranty.
•Donotwashtheunitwithanythinnerorchemicalsolvent
•Storeyourthermometerinadrylocation,freefromdustandcontaminantsandawayfromdirect
sunlight
Replacing the Batteries
WhenthebatterysymbolonLCDdisplaytwinklescontinuallyreplace with new battery.
1.Insertcoinintoslot.RotatedooruntilslotislinedwithUNLOCKsymbol.
2.Replacebattery
3.RotatebatterydoortoLOCKEDposition.
Errors and Troubleshooting
Whenmeasuredtemperatureishigherthan42.9°C,LCDwilldisplay“Err°C”
andrelevantageicon.Redbacklightstaysonfor5seconds.
Whenambienttemperatureisoutofrange(seeProductSpecicationsbelow)
orothersystemerrorsoccursuchasshortorbrokencircuit,LCDwilldisplay“Err
toindicatesystemerror.Redbacklightstaysonfor5seconds.
Limited Two Year Warranty
Kazwarrantsthisproductagainstanydefectsthatareduetofaultymaterialorworkmanshipforaperiod
oftwoyearsfromtheoriginaldateofconsumerpurchaseorreceiptasagift.Thiswarrantyapplieswhen
usedfornormalhouseholduseinaccordancewiththeUseandCareManualandexcludesthebatteryand
damagetotheproductresultingfromaccidentormisuse.Thisproductisnotwarrantedwhenusedina
professionalenvironment.
InnoeventshallKazbeliableforanyspecial,incidental,indirectorconsequentialdamagesinconnection
withthepurchaseoruseofthisproductorcostsovertheoriginalcostofproduct.
Iftheproductshouldnotperformtospecicationswithinthewarrantyperiod,pleasecontactConsumer
Relationsat1-800-477-0457oremailatc[email protected]morwritetoKazUSAInc,Consumer
RelationsDepartment,250TurnpikeRoad,Southborough,MA01772.InCanada,youcancontactus
at510BronteStreetS,Milton,ON,L7T2X6,Canada.Kazreservestherighttoreplaceanonconforming
productwiththemostcomparableproductcurrentlyavailable.Thisproducthasaveyearminimum
expectedlifetime.
Product Specications
Displayedtemperaturerange:32.0°C-42.9°C(89.6°F-109.2°F)
Operatingambienttemperaturerange:10–40°C(50–104°F)
andrelativehumidityrangeof15%~95%
Displayresolution:0.1°Cor°F
AccuracyfordisplayedtemperaturerangeMaximumLaboratoryError
35°C–42°C(95.9°F–107.6°F):±0.1°C(±0.2°F)atanambientof23±5°C
outsidethisrange:±0.2°C/0.4°F(within32.0°C-42.9°C(89.6°F-109.2°F))
Batterylife:500timesmeasurementswithin2years
Servicelife:2000measurements
Storage/Transporttemperature-25-55±2°Cand15-95RH%±5%
and relative humidity
Ifthedeviceisnotusedwithinspeciedtemperatureandhumidityrangesthetechnicalaccuracyofthe
measurement cannot be guaranteed.
Explanation of symbols
TypeBFappliedparts Seeinstructionforuse
Operating temperature  Storagetemperature
Keep dry
IP22:Protectedagainstsolidforeignobjectsof12.5mmdiameterandgreater.Protectedagainstvertically
fallingwaterdropswhenthedeviceistiltedupto15degrees.
Thisthermometerisspeciedtooperateat1atmosphericpressureorataltitudeswithanatmospheric
pressure up to 1 atmospheric pressure (760-1060 hPa).
SeeInstructionforuseEquipmentwithtypeBFappliedparts
Subjecttochangewithoutnotice.
Thisapplianceconformstothefollowingstandards:
StandardReferenceEditionTitle:EN12470-3:2003Clinicalthermometers-Part3:Performanceofcompact
electrical thermometers (non-predictive and predictive) with maximum device.
EN60601-1:2006Medicalelectricalequipment–Part1:Generalrequirementsforbasicsafetyand
essentialperformance.
English
Français
GB
FR
Guidanceandmanufacturer’sdeclaration–electromagneticemissions
ThePRT2000equipmentisintendedforuseintheelectromagneticenvironmentspeciedbelow.
ThecustomerortheuserofthePRT2000shouldassurethatitisusedinsuchanenvironment.
Emissions TestComplianceElectromagnetic environment – guidance
RFEmissions
CISPR11 Group 1
TheMEequipmentusesRFenergyonlyforit’sinter-
nalfunction.Therefore,itsRFemissionsareverylow
andarenotlikelytocauseanyinterferenceinnearby
electronic equipment.
RFEmissions
CISPR11 Class BComplies
HarmonicemissionsIEC
61000-3-2 Not Applicable
TheMEequipmentis
solely battery powered.
Voltageuctuations/
icker emissionsNot Applicable
Non-Life Support Equipment Separation Distance Calculation
(3Vrms / 3V/m compliance)
Ratedmaximumoutput
poweroftransmitter(W)
Separationdistanceaccordingtofrequencyoftransmitter(m)
150kHzto80MHzin
ISMbands
80MHzto800MHz800MHzto2.5GHz
d = [ 7 ] P
E1
0.01/0.120.23
0.1 /0.730.38
1/1.22.3
10 /7.33.8
100/1223
d = [
3,5] P
V
1
d = [3,5] P
E1
Guidance and manufacturer’s declaration – electromagnetic immunity
ThePRT2000isintendedforuseintheelectromagneticenvironmentspeciedbelow.
ThecustomerortheuserofthePRT2000shouldassurethatitisusedinsuchanenvironment.
Immunity testIEC60601 test
level
Compliance
level
Electromagnetic environment
– guidance
Electrostatic discharge
(ESD)
IEC61000-4-2
±6kVContact
±8kVAir Complies
Floorsshouldbewood,concrete,
orceramictile.Ifoorsare
coveredwithsyntheticmaterial,
the relative humidity should be
atleast30%
RadiatedRF
IEC61000-4-3
3V/m80MHzto
2.5GHz Complies
Fieldstrengthsoutsidethe
shieldedlocationfromxedRF
transmitters,asdeterminedby
anelectromagneticsitesurvey,
shouldbelessthan3V/m.
Interferencemayoccurinthe
vicinityofequipmentmarked
withthefollowingsymbol:
Separationdistancecalculation
providedabove.Ifaknown
transmitterispresentthespecic
distance can be calculated using
the equations.
ConductedRF
IEC61000-4-6
3Vrms150kHzto
80MHz
Not Applicable
(no electrical
cabling)
Electricalfasttransient
IEC61000-4-4
±2kVpowerline
±1kVI/Olines Not Applicable
TheMEequipment
is solely battery powered.
Surge
IEC61000-4-5
±1kV
dierential
±2kVcommon
Not Applicable
Powerfrequency
magneticeld
IEC61000-4-8
3 A/mComplies
Powerfrequency
magneticeldsshouldbeat
levelscharacteristicofa
typical location in a typical
commercial or hospital
environment.
Voltagedips,short
interrupts and voltage
variations on power
supply input lines
IEC61000-4-11
>95%dip0.5
cycle
60%dip5cycles
70%dip25cycles
95%dip5sec.
Not Applicable
TheMEequipment
is solely battery
powered.
ENISO14971:2012Medicaldevices–Applicationofriskmanagementtomedicaldevices.
ENISO10993-1:2009Biologicalevaluationofmedicaldevices–Part1:EvaluationandTesting.
EN60601-1-2:2007Medicalelectricalequipment–part1-2:Generalrequirementsforbasicsafetyandes-
sentialperformance–Collateralstandard:electromagneticcompatibility–Requirementsandtests
EN980:2008Symbolsforuseinlabelingofmedicaldevices.
EN1041:2008Informationsuppliedbythemanufacturerofmedicaldevices.
EN60601-1-11:2010Medicalelectricalequipment--Part1-11:Generalrequirementsforbasicsafetyand
essentialperformance--Collateralstandard:Requirementsformedicalelectricalequipmentandmedical
electrical systems used in the home healthcare environment.
ThisproductconformstotheprovisionsoftheECdirective93/42/EEC.
MEDICALELECTRICALEQUIPMENTneedsspecialprecautionsregardingEMC.Fordetaileddescriptionof
EMCrequirementspleasecontactourConsumerRelationsDepartment.
PortableandmobileRFcommunicationsequipmentcanaectMEDICALELECTRICALEQUIPMENT.
Pleasedonotdisposeoftheproductinthehouseholdwasteattheendofitsusefullife.Disposal
can take place at your local retailer or at appropriate collection points provided in your country.
Toprotecttheenvironment,disposeofemptybatteriesatappropriatecollectionsitesaccordingto
national or local regulations.
1HerzogL,PhillipsSG.Addressingconcernsaboutfever.ClinPediatr(Phila)2011May;50(5):383-90.
2Sund-LevanderM,ForsbergC,WahrenLK.Normaloral,rectal,tympanicandaxillarybodytemperature
inadultmenandwomen:asystematicliteraturereview.ScandJCaringSci2002June;16(2):122-8.
Age Precision
Digital
Thermometer
PRT 2000
Age PrecisionMC
Thermomètre
numérique
Downloaded from www.vandenborre.be

Beoordeel deze handleiding

4.0/5 (7 Beoordelingen)

Product specificaties

Merk: Braun
Categorie: Thermometer
Model: Age Precision PRT 2000

Heb je hulp nodig?

Als je hulp nodig hebt met Braun Age Precision PRT 2000 stel dan hieronder een vraag en andere gebruikers zullen je antwoorden