Blaupunkt SCM-S1 Handleiding


Lees hieronder de đź“– handleiding in het Nederlandse voor Blaupunkt SCM-S1 (2 pagina's) in de categorie Alarmsysteem. Deze handleiding was nuttig voor 30 personen en werd door 2 gebruikers gemiddeld met 4.5 sterren beoordeeld

Pagina 1/2
Wireless Shutter Motor Control (SCM S1)-
P arts Description
1. LED Indicator
2. Learn Button
3. AC Line Power Input
4. AC Neutral Power Input
5. Local Switch Open Direction
6. Local Switch Close Direction
7. Motor Output Open Direction
8. Motor Output Close Direction
Setup and Installation of SCM S1 should only be performed by a -
person with knowledge in handling electricity power. adequate DO
NOT attempt installation if you do not possess required skill.
1. Connect AC power to the Power input terminals. Turn off AC
power before connection to ensure safety.
2. Refer to your Control Panel manual to put panel into learning
mode.
3. Turn on the AC power, then press and hold the Learn button for
about 10 seconds and release when LED flashes once. Wait a
few seconds.
4. If learning is successful, the LED will flash twice. Refer to panel
manual to complete the learning process.
The device should be connected to the roller shutter motor to
control the shutter operation. Optional external switch may be
connected to the device to provide manual shutter control.
Wire the device according to diagram below.
A: AC Power
B: Optional External Switch
C: Shutter Motor
Shutter Control
The shutter device can control wired motor to open or clos via
remote control using Blaupunkt Home Connect server and
Secure4Home smartphone app. If external switch is wired to the
device, you can also use the switch to control shutter.
When set to open or close, the device will activated the motor
toward open or close direction for 4 minutes.
Remote Control
Use the web or app to control device. Avaialble options include Up,
down, stop and percentage control.
Manual Control
Use the external switch to control device. When the motor is
already moving in one direction, activating the switch for opposite
direction will stop the motor. Activate the switch again to start
moving the motor again.
Open/Close Time Calibration.
By default, the device will activate the for 4 minute when motor
you choose to open or close the shutter. The 4 minute time period -
can be adjusted to accomodate your shutter length. To performm
calibration, the device must first be wired to external switch first.
1. Press and hold the Learn Button for 3~10 seconds. Do not hold
for over 10 seconds otherwise the device will be removed from
Control Panel.
2. When the button is released, the device will activate motor to
roll toward Open direction for 4 minutes.
3. Wait for 4 minutes for Shutter Control to stop rolling to “Open”
direction, then activate the connected external local “ ” Close
switch to close the shutter.
4. Activate the external local “ ” Open switch the moment
the shutter is fully closed. The Shutter control will record
to time it took between step 3 and 4 as the new “close
time”.
5. The Shutter Control will roll toward open direction then
after step 4.
6. Activate the external local switch “ ” Close the moment
the shutter is fully opened. The Shutter control will
record to time it took between step 5 and 6 as the new
“ ”.open time
7. Example
If it takes 30 seconds for the shutter to move from Open
to Close, and 40 seconds to move from Close to Open,
the new close time will be 30 seconds and new open
time will be 40 seconds.
After calibration, whenever the Shutter Control receives
close command, it will roll toward close direction for 30
seconds. When it receives open command, it will roll
toward open for 40 seconds.
Learning
Operation
Installation
Environmental Condition
- - 10°C to 40°C, relative humidity 85% non condensing.
Radio
2.4GHz
Operation Load
110V: 440W / 4A
230V: 920W / 4A
Specification


Product specificaties

Merk: Blaupunkt
Categorie: Alarmsysteem
Model: SCM-S1

Heb je hulp nodig?

Als je hulp nodig hebt met Blaupunkt SCM-S1 stel dan hieronder een vraag en andere gebruikers zullen je antwoorden




Handleiding Alarmsysteem Blaupunkt

Handleiding Alarmsysteem

Nieuwste handleidingen voor Alarmsysteem