Best ILB9 Handleiding


Bekijk gratis de handleiding van Best ILB9 (12 pagina’s), behorend tot de categorie Afzuigkap. Deze gids werd als nuttig beoordeeld door 11 mensen en kreeg gemiddeld 4.6 sterren uit 6 reviews. Heb je een vraag over Best ILB9 of wil je andere gebruikers van dit product iets vragen? Stel een vraag

Pagina 1/12
Page 1
MODELS ILB9 ILB11
WARNING
TO REDUCE THE RISK OF FIRE, ELECTRIC SHOCK, OR INJURY
TO PERSONS, OBSERVE THE FOLLOWING:
1. Use this unit only in the manner intended by the manufacturer. If
youhave questions, contact the manufacturer at the address or
telephone number listed in the warranty.
2. Beforeservicingorcleaningunit,switchpoweroffatservicepanel
and lock the service disconnecting means toprevent power from
being switched on accidentally. When the service disconnecting
means cannot be locked, securely fasten a prominent warning
device, such as a tag, to the service panel.
3. Installationworkandelectricalwiringmustbedonebya qualified
person(s)inaccordancewithallapplicablecodesandstandards,
including fire-rated construction codes and standards.
4. Sufficient air is needed forproper combustion and exhausting of
gasesthroughtheflue(chimney)offuelburningequipmenttopre-
vent backdrafting. Follow the heating equipment manufacturer’s
guideline and safety standards such as those published by the
National Fire Protection Association (NFPA), and the American
SocietyforHeating,RefrigerationandAirConditioningEngineers
(ASHRAE), and the local code authorities.
5. Whencuttingordrillingintowallorceiling,donotdamageelectri-
cal wiring and other hidden utilities.
6. Ducted fans must always be vented to the outdoors.
7. To reduce the risk of fire, use only metal ductwork.
8. Ifthisunitisto
beinst
alledovera tuborshower,itmustbemarked
as appropriate for the application and be connected to a GFCI
(Ground Fault Interrupter) - protected branch circuit.
9. Neverplacea switch where it can be reached froma tubor
shower.
10.This unit must be grounded.
TO REDUCE THE RISK OF A RANGE TOP GREASE FIRE:
1. Never leave surface units unattended at high settings. Boilovers
cause smoking and greasy spillovers that may ignite. Heat oils
slowly on low or medium settings.
2. AlwaysturnhoodONwhencookingathighheatorwhenflambe-
ing food (i.e. Crepes Suzette, Cherries Jubilee, Peppercorn Beef
Flambe’).
3. Clean ventilating fans frequently. Grease should not be allowed
to accumulate on fan or filter.
4. Use proper pan size.Always use cookware appropriate for the
size of the surface element.
TO REDUCE THE RISK OF INJURY TO PERSONS IN THE EVENT
OF A RANGE TOP GREASE FIRE, OBSERVE THE FOLLOWING:*
1. SMOTHERFLAMESwitha close-fittinglid,cookiesheet,or
metal tray,then turn off the burner. BE CAREFUL TOPREVENT
BURNS.Iftheflamesdonotgooutimmediately,EVACUATEAND
CALL THE FIRE DEPARTMENT.
2. NEVER PICK UP A FLAMING PAN - Youmay be burned.
3. DONOTUSEWATER,includingwetdishclothsortowels- violent
steam explosion will result.
IN-LINE BLOWERS
READ AND SAVE THESE INSTRUCTIONS
Installer: Leave this manual with
the homeowner.
Homeowner: Use and Care
information on page 4.
!
FOR DOMESTIC COOKING ONLY
!
WARNING
4. Use an extinguisher ONLY if:
A. You know you have a Class ABC extinguisher and you already
know how to operate it.
B. The fire is small and contained in the area where it started.
C. Thefiredepartmentisbeingcalled.
D. You can fight the fire with your back to an exit.
* Based on “Kitchen Fire Safety Tips” published by NFPA.
CAUTION
!
1. Forgeneralventilatinguseonly.Donotusetoexhausthazardous
or explosive materials and vapors.
2. Toavoid motor bearing damage and noisy and/or unbalanced
impellers, keep drywall spray, construction dust, etc. off power
unit.
3. If ventilator is installed in an unconditioned space (such
as an attic): Surround the ventilator with thermal insulation - to
minimize possible condensation.
4. Please read specification label on product forfurther information
andrequirements.
TABLE OF CONTENTS
This manual is divided into sections as follows:
“TYPICAL INSTALLATION”
This section shows a common installation.
- Mounting (New Frame Construction)
- Mounting (Existing Frame Construction)
- Mounting Using Hanger Kit (included)
- Ducting (Horizontal blower discharge)
-Wiring
“MOUNTING OPTIONS”
“WIRING PLATE POSITION”
“DUCTING OPTIONS”
- Blower Discharge Positions
- Ducting (Vertical blower discharge)
“USE AND CARE”
“SERVICE PARTS”
“WARRANTY”

Beoordeel deze handleiding

4.6/5 (6 Beoordelingen)

Product specificaties

Merk: Best
Categorie: Afzuigkap
Model: ILB9

Heb je hulp nodig?

Als je hulp nodig hebt met Best ILB9 stel dan hieronder een vraag en andere gebruikers zullen je antwoorden