Best WPD38I42SB Handleiding

Best Afzuigkap WPD38I42SB

Lees hieronder de 📖 handleiding in het Nederlandse voor Best WPD38I42SB (36 pagina's) in de categorie Afzuigkap. Deze handleiding was nuttig voor 33 personen en werd door 2 gebruikers gemiddeld met 4.5 sterren beoordeeld

Pagina 1/36
WPD38I SERIES
HB0113
INSTALLATION INSTRUCTIONS
INTENDED FOR DOMESTIC COOKING ONLY
INSTALLER: LEAVE THIS MANUAL WITH HOMEOWNER.
HOMEOWNER: USE AND CARE INFORMATION ON PAGE 9.
READ AND SAVE THESE INSTRUCTIONS
SV20569 rev. 05
! !
BEST; Hartford, Wisconsin www.BestRangeHoods.com 800 558-1711
BEST; Drummondville, QC, Canada www.BestRangeHoods.com 866 737-7770
To register your product online or for additional information visit www.BestRangeHoods.com
SUITALE FOR USE IN DAMP LOCATIONS WHEN INSTALLED IN A
GFCI PROTECTED BRANCH-CIRCUIT.
I NTENDED FOR OUTDOOR COVERED PATIO OR LANAI AREA .
2
TO REDUCE THE RISK OF FIRE, ELECTRIC SHOCK OR
INJURY TO PERSONS, OBSERVE THE FOLLOWING:
1. Use this unit only in the manner intended by the manufacturer.
If you have questions, contact the manufacturer at the address
or telephone number listed in the warranty.
2. Before servicing or cleaning unit, switch power off at service
panel and lock service disconnecting means to prevent
power from being switched on accidentally. When the service
disconnecting means cannot be locked, securely fasten a
prominent warning device, such as a tag, to the service panel.
3. Installation work and electrical wiring must be done by
qualified personnel in accordance with all applicable codes
and standards, including fire-rated construction codes and
standards.
4. Sufficient air is needed for proper combustion and exhausting
of gases through the flue (chimney) of fuel burning equipment
to prevent backdrafting. Follow the heating equipment
manufacturers guidelines and safety standards such as
those published by the National Fire Protection Association
(NFPA) and the American Society for Heating, Refrigeration
and Air Conditioning Engineers (ASHRAE) and the local code
authorities.
5. When cutting or drilling into wall or ceiling, do not damage
electrical wiring and other hidden utilities.
6. Ducted fans must always be vented to the outdoors.
7. Do not use this unit with any additional solid-state speed
control device.
8. To reduce the risk of fire, use only metal ductwork.
9. This unit must be grounded and protected by a GFCI.
10. Suitable for use in damp locations only when installed in a
GFCI PROTECTED branch-circuit.
11. This unit is not designed to be used with a charcoal grill.
12. When applicable local regulations comprise more
restrictive installation and/or certification requirements,
the aforementioned requirements prevail on those of this
document and the installer agrees to conform to these at his
own expense.
TO REDUCE THE RISK OF A RANGE TOP GREASE FIRE:
a) Never leave surface units unattended at high settings. Boilovers
cause smoking and greasy spillovers that may ignite. Heat oils
slowly on low or medium settings.
b) Always turn hood ON when cooking at high heat or when
flambeing food (i.e.: Crêpes Suzette, Cherries Jubilee,
Peppercorn Beef Flambé).
c) Clean ventilating fans frequently. Grease should not be allowed
to accumulate on fan, filters or in exhaust ducts.
d) Use proper pan size. Always use cookware appropriate for the
size of the surface element.
1. For general ventilating use only. Do not use to exhaust
hazardous or explosive materials and vapors.
2. To avoid motor bearing damage and noisy and/or unbalanced
impellers, keep drywall spray, construction dust, etc. off power
unit.
3. Your hood motor has a thermal overload which will
automatically shut off the motor if it becomes overheated. The
motor will restart when it cools down. If the motor continues to
shut off and restart, have the hood serviced.
4. For best capture of cooking impurities, the bottom of the hood
must be located at a distance of 36" above cooking surface.
5. Two installers are recommended because of the large size and
weight of this hood.
6. To reduce the risk of fire and to properly exhaust air, be sure to
duct air outside — Do not exhaust air into spaces within walls
or ceiling or into attics, crawl space or garage.
7. This product is equipped with a thermostat which may start
blower automatically. To reduce the risk of injury and to prevent
power from being switched on accidentally, switch power off at
service panel and lock or tag service panel.
8. Please read specification label on product for further
information and requirements.
WARNING
!
CAUTION
TO REDUCE THE RISK OF INJURY TO PERSONS IN THE
EVENT OF A RANGE TOP GREASE FIRE, OBSERVE
THE FOLLOWING*:
1. SMOTHER FLAMES with a close-fitting lid, cookie sheet or
metal tray, then turn off the burner. BE CAREFUL TO PREVENT
BURNS. IF THE FLAMES DO NOT GO OUT IMMEDIATELY,
EVACUATE AND CALL THE FIRE DEPARTMENT.
2. NEVER PICK UP A FLAMING PAN — You may be burned.
3. DO NOT USE WATER, including wet dishcloths or towels
This could cause a violent steam explosion.
4. Use an extinguisher ONLY if:
A. You own a Class ABC extinguisher and you know how to
operate it.
The fire is small and contained in the area where it started.B.
The fire department has been called.C.
You can fight the fire with your back to an exit.D.
* Based on “Kitchen Fire Safety Tips” published by NFPA.
WARNING
!
3
- WPD38I SERIES RANGE HOOD SYSTEM -
HL0184
M 437ODEL
(H IGH CAPACITY ROOF CAP)
M 441ODEL
(10’ )ROUND WALL CAP
MODEL 418
(10” ROUND
ADJUSTABLE ELBOW ,
OPTIONAL)
M 410ODEL
(10” ROUND DUCT
— 2 )FT. SECTIONS
OPTIONAL
DECORATIVE FLUE
AEWPD SERIES
OPTIONAL
WALL EXTENSION
AWWPD SERIES
10” ROUND ADAPTER
( )INCLUDED
OPTIONAL BACKSPLASH
(ABWPD SERIES)
(STAINLESS STEEL WALL COVERING
WITH WARMING SHELVES )
36”, 42” OR 48 WIDTHS
D BUAL LOWER
( )INCLUDED
WPD38I SERIES
RANGE HOOD


Product specificaties

Merk: Best
Categorie: Afzuigkap
Model: WPD38I42SB

Heb je hulp nodig?

Als je hulp nodig hebt met Best WPD38I42SB stel dan hieronder een vraag en andere gebruikers zullen je antwoorden




Handleiding Afzuigkap Best

Handleiding Afzuigkap

Nieuwste handleidingen voor Afzuigkap