Important Safety Messages
SAVE THESE INSTRUCTIONS - This manual contains important instructions that should be followed during
installation and maintenance of the Smart-UPS and batteries.
Read these instructions carefully and look at the equipment to become familiar with the device before trying to install,
operate, service or maintain it. The following special messages may appear throughout this bulletin or on the equipment
to warn of potential hazards or to call attention to information that clarifies or simplifies a procedure.
The addition of this symbol either to a “Danger” or “Warning” safety label indicates that an electrical
hazard exists which will result in personal injury if the instructions are not followed.
This is the safety alert symbol. It is used to alert you to potential personal injury hazards. Obey all safety
messages that follow this symbol to avoid possible injury or death.
Product Handling Guidelines
DANGER
DANGER indicates a hazardous situation which, if not avoided, will result in death or serious
injury.
WARNING
WARNING indicates a hazardous situation which, if not avoided, could result in death or serious
injury.
CAUTION
CAUTION indicates a hazardous situation which, if not avoided, could result in minor or moderate
injury.
NOTICE
NOTICE is used to address practices not related to physical injury.
<18 kg
<40 lb
18-32 kg
40-70 lb
32-55 kg
70-120 lb
>55 kg
>120 lb
Smart-UPS On-Line External Battery Pack SRT96BP/72BP2
Safety and General Information
• Adhere to all national and local electrical codes.
• Changes and modifications to this unit not expressly approved by APC by Schneider Electric could void the
warranty.
• This unit is intended only for indoor use in a controlled environment.
• Do not operate this unit in direct sunlight, in contact with fluids, or where there is excessive dust or humidity.
• Be sure the air vents on the unit are not blocked. Allow adequate space for proper ventilation.
• The battery typically lasts for three to five years. Environmental factors impact battery life. Elevated ambient
temperatures, poor quality mains power, and frequent short duration discharges will shorten battery life.
• The equipment is heavy. Always practice safe lifting techniques adequate for the weight of the equipment.
• The batteries are heavy. Remove the batteries before installing the UPS and external battery packs (XLBPs) in a
rack.
• Always install XLBPs at the bottom in rack-mount configurations. The UPS must be installed above the XLBPs.
• The UPS will recognize as many as 10 XLBPs connected to the UPS.
Note: For each XLBP added, increased recharge time will be required.
• Always recycle used batteries.
• Recycle the package materials or save them for reuse.
• Additional safety information can be found in the Safety Guide supplied with this unit.
Battery safety
• Replace batteries with the same number and type of batteries as originally installed in the equipment.
• Schneider Electric uses Maintenance-Free sealed Lead Acid batteries. Under normal use and handling, there is
no contact with the internal components of the battery. Over charging, over heating or other misuse of batteries
can result in a discharge of battery electrolyte. Released electrolyte is toxic and may be harmful to the skin and
eyes.
• CAUTION: Before installing or replacing the batteries, remove jewelry such as wristwatches and rings.
High short circuit current through conductive materials could cause severe burns.
• CAUTION: Do not dispose of batteries in a fire. The batteries may explode.
• CAUTION: Do not open or mutilate batteries. Released material is harmful to the skin and eyes and may be
toxic.
Overview
• To verify that installation of an external battery pack (XLBP) has been successful, go to the UPS display
interface.
Perform a Visible Alarm Test to determine if the XLBP is recognized by the UPS.
The LED on the XLBP will flash if successful communication has been established.
• When viewing the status of an XLBP on the UPS display interface screen, the LED on the corresponding XLBP
will flash.
• When an RBC needs to be replaced, perform a Runtime Calibration Test to verify that battery replacement is
required.
Smart-UPS On-Line External Battery Pack SRT96BP/72BP 3
Package Contents
Inspect the contents upon receipt. Notify the carrier and dealer if there is damage.
Included with all models
Front bezel Ground cable
2 pan head screws to secure the
ground cable
2 tie brackets
4 flat head screws to secure tie
brackets
User Documentation CD
1 pan head screw to secure the
XLBP battery cable connector to
an XLBP or to the UPS.
Included with Tower models only
Stabilizer brackets are supplied with the UPS models
The XLBP includes 1 pair of stabilizer bracket connectors
4 flat head screws to secure tower stabilizer
brackets to the UPS
Included with Rack-Mount models only
Rail Kit with instructions and hardware for
installing rails in a rack
• 1 pair rack-mount brackets
• 6 flat head screws to secure rack-mount brackets to the UPS
• 4 ornamental screws to secure rack-mount brackets to the rails
su04
34a
x6
x4


Product specificaties

Merk: Apc
Categorie: UPS
Model: Smart-UPS SRT96BP

Heb je hulp nodig?

Als je hulp nodig hebt met Apc Smart-UPS SRT96BP stel dan hieronder een vraag en andere gebruikers zullen je antwoorden




Handleiding UPS Apc

Handleiding UPS

Nieuwste handleidingen voor UPS