Bekijk gratis de handleiding van Apc Back- 500VA (8 pagina’s), behorend tot de categorie UPS. Deze gids werd als nuttig beoordeeld door 15 mensen en kreeg gemiddeld 4.9 sterren uit 4 reviews. Heb je een vraag over Apc Back- 500VA of wil je andere gebruikers van dit product iets vragen? Stel een vraag
Pagina 1/8

1
Place the Back-UPS to avoid:
– Direct sunlight
– Excessive heat
– Excessive humidity or contact with fluids
bu054a
ON/OFF and
LED Status
Indicator Battery backup and
surge protected outlets
2
3
990-3333B-005 © 2009 American Power Conversion Corp.
All other trademarks are property of their respective owners.
APC, Back-UPS and PowerChute are registered trademarks of American Power Conversion Corp.
Connect the Battery and Turn on the Unit
Connect the battery to the UPS before use. To connect the battery:
Pull the top of the battery connector lever out of the unit, until the lever is horizontal.
Push the battery connector lever completely into the unit, until the end of the lever is flush with the rear panel.
Press ON/OFF to turn on the unit.
A single short beep, and the green “Power On” indicator confirms that the Back-UPS is on and ready to provide
protection.
The Back-UPS should charge for at least 10 hours to ensure sufficient runtime. The unit is being charged
whenever it is connected to utility power, whether the unit is turned ON or OFF.
Status Indicators
The Back-UPS indicates its operating status using a combination of visual and audible indicators.
Power On LED BuzzerCondition
OnOff On-line - Back-UPS is supplying conditioned utility power
to the connected equipment
On (Off during 4
beeps) 4 beeps repeated
every 30 seconds
On-Battery- Back-UPS is supplying battery power
FlashingRapid Beeping
(every 1/2 second)
Low Battery Warning - The Back-UPS has 1.5 minutes of
remaining battery power
FlashingConstant toneBad Battery Detected - Battery needs to be charged, or is
at end of life. (See Battery Replacement.)
OffShort beep every
4 seconds
Low Battery Shutdown - During On Battery operation the
battery power was almost completely exhausted, and the
Back-UPS is waiting for utility power to return to normal
OffConstant ToneOn Battery Overload - Connected equipment requires
more power than provided by the Back-UPS battery.
Unplug devices one at a time to remove overload, if not
corrected Contact APC Technical Support
On Constant Tone On Line Overload - The power drawn by the connected
equipment exceeds the power capacity of the Battery
Backup
Flashing Chirp every 2
seconds
Charger Warning -Back-UPS has experienced an internal
problem, but continues to power the load. Contact APC
Technical Support
OffConstant ToneCharger Fault - Back-UPS has an internal problem, and is
no longer powering the load. Contact APC Technical
Support
Adjusting Transfer
Voltage and Sensitivity
Settings
Automatic Voltage Regulation boosts the utility voltage
when it drops below safe levels. This allows the
equipment plugged into the unit to operate during low
voltage conditions, conserving the battery power in the
event of a power outage.
The Back-UPS will switch to battery power if the input
voltage level becomes too low for the Automatic
Voltage Regulation to compensate, or if the utility
power is distorted.
If the Back-UPS switches to battery power too
frequently or too infrequently, adjust the transfer
voltage and sensitivity settings:
1. Ensure the Back-UPS is off. Plug it into utility
power.
2. Press and hold ON/OFF until the LED repeatedly
flashes. The unit is now in Program Mode.
3. Release the button. The LED will flash once,
twice, or three times per second, indicating the
current setting. See Transfer Voltage and
Sensitivity Settings.
4. Press ON/OFF within two seconds to change the
setting. Each time the button is pressed, the LED
will flash at a different rate: once, twice, or three
times per second, indicating the new setting.
Continue pressing the button until the desired
setting is reached. If the button is not pressed
within five seconds, the Back-UPS will exit the
Program Mode.
5. To exit Program Mode, release the button and
wait for the LED to stop flashing.
Connect Equipment
Battery Backup Surge Protection
These outlets are powered whenever the Back-UPS is switched
ON. During a power outage, or other utility problems (brownouts,
over-voltages), these outlets will be powered for a limited time by
the Back-UPS. Plug the computer and monitor into these two
outlets.
Connect AC Power Cord
Plug the Back-UPS power cord into a wall outlet, not a surge
protector or power strip. The outlet should be near the equipment
and easily accessible.
Back-UPS® RS 500
BR500CI-AS User Guide
Transfer Voltage and Sensitivity Settings
LED FlashingTransfer Voltage
Setting
Input Voltage
Range
(For Utility
Operation)
Usage
Once per secondLow155 - 280The Back-UPS will switch to battery power less often. Use with equipment that is not
sensitive to low or high level voltage levels or minor voltage waveform distortions.
Twice per secondMedium
(factory default)160 -280Default, use in normal conditions.
Three times per second
High165 - 270The Back-UPS will switch to battery power during any small fluctuation in voltage.
Use with equipment that is sensitive to low or high level voltage levels or minor
voltage waveform distortions.
bu053a
Product specificaties
| Merk: | Apc |
| Categorie: | UPS |
| Model: | Back- 500VA |
| Kleur van het product: | Zwart |
| Gewicht: | 4900 g |
| Breedte: | 115 mm |
| Diepte: | 213 mm |
| Hoogte: | 185 mm |
| Snoerlengte: | 1.8 m |
| Gewicht verpakking: | 5500 g |
| LED-indicatoren: | Stroom |
| Vormfactor: | Mini Tower |
| Afmetingen verpakking (BxDxH): | 190 x 291 x 257 mm |
| Geluidsalarm(en): | Ja |
| Duurzaamheidscertificaten: | RoHS |
| Uitgangsvermogen: | 300 W |
| Accu/Batterij oplaadtijd: | 10 uur |
| Temperatuur bij opslag: | -15 - 45 °C |
| Frequentie: | 50/60 Hz |
| Luchtvochtigheid bij opslag: | 0 - 95 procent |
| Hoogte, in bedrijf: | 0 - 3000 m |
| Hoogte bij opslag: | 0 - 15000 m |
| Stekker: | C14 stekker |
| Relatieve vochtigheid in bedrijf (V-V): | 0 - 95 procent |
| Batterijtechnologie: | Sealed Lead Acid (VRLA) |
| Surge energy rating: | 240 J |
| Aantal AC uitgangen: | 4 AC-uitgang(en) |
| Stopcontacttypes: | C13 stekker |
| Output power capacity: | 0.5 kVA |
| Ingang operation voltage (min): | - V |
| Ingang operation voltage (max): | 230 V |
| Uitgang operation voltage (min): | - V |
| Uitgang operation voltage (max): | 230 V |
| Aantal input fases: | 1 |
| Typische backup tijd op halve lading: | 1 min |
| Typische backup tijd op volledige lading: | 70 min |
| Output connectietype: | IEC 320 C13 |
| Aantal output fases: | 3 |
| Spanningsbeveiliging: | Ja |
Heb je hulp nodig?
Als je hulp nodig hebt met Apc Back- 500VA stel dan hieronder een vraag en andere gebruikers zullen je antwoorden
Handleiding UPS Apc
8 Augustus 2026
16 Juni 2026
15 Juni 2026
15 Juni 2026
5 Februari 2026
24 Januari 2026
3 November 2025
11 September 2025
11 September 2025
10 September 2025
Handleiding UPS
Nieuwste handleidingen voor UPS
22 Juni 2026
5 Mei 2026
5 Mei 2026
14 April 2026
5 April 2026
5 April 2026
31 Maart 2026
26 Maart 2026
26 Maart 2026
26 Maart 2026