Andrews Mistral Heat Pump Handleiding

Andrews Airconditioner Mistral Heat Pump

Lees hieronder de đź“– handleiding in het Nederlandse voor Andrews Mistral Heat Pump (2 pagina's) in de categorie Airconditioner. Deze handleiding was nuttig voor 32 personen en werd door 2 gebruikers gemiddeld met 4.5 sterren beoordeeld

Pagina 1/2
andrews-sykes.com
Mistral Heat Pump
Operating Instructions
& Safety Guide
Maintenance
General Safety
Electrical Safety
0800 211 611
Laying Up
Getting Started and Operation
Air Conditioner
This equipment should only be used by a competent
person who has read and understood these
instructions.
Check condition of equipment before use. If unit is
showing any signs of damage contact your supplier
immediately.
Never operate this equipment if you are ill, feeling tired
or under the inuence of alcohol or drugs.
Keep all vents and grills clear of obstructions.
Keep children and animals away from air conditioning
units. Never leave them alone when the unit is in use.
Make sure equipment is switched o and unplugged
after use.
Do not use the unit where sunlight is shining directly
on to it
This unit requires a 230 volt electrical supply. It plugs into
standard domestic 13 amp socket.
Always inspect plugs and power cables for damage before
plugging into power supply.
DO NOT USE IF ANY DAMAGE IS FOUND.
Ensure cables are installed to prevent hazards.
If an extension lead is used, ensure it is of the correct
standard and fully uncoiled before use.
Cables must not be laid in wet or damp areas.
Do not move equipment while operating.
Do not pull equipment by the power lead.
It is recommended that this equipment is protected by an
RCD when in use.
Disconnect from electrical supply before any cleaning or
maintenance.
Do not use chemical solvents to clean the surface of the unit.
Use a clean damp cloth.
Check the Air lter every week. (Fig 4)
Remove the air lter, the element may be vacuumed clean or
washed in a neutral and detergent mix (40°C).
Rinse and dry the lter before replacing.
Do not dry in direct sunlight.
1. Clean Filter.
2. Clean surfaces.
3. Drain water from unit. Please note water will drain from
the low level water drain (g5) when the stopper is removed.
Run in fan mode until the pipe is dry.
DO NOT DO THIS ON ANY INDOOR FLOOR SURFACES.
4. When the unit is clean and drained, store in a clean, dry
area. Stow cable.
Never operate the unit in very hot or cold conditions – it
works properly at temperatures between 15°C and 31°C.
Always allow the unit to stand/settle for 15 minutes before
switching on when either setting or restarting.
Position the mobile air conditioner in a at location where
the air outlets cannot be covered up. Place the unit no less
than 50cm away from a wall or other obstacle.
Fit the square end of the exhaust duct to the exhaust
terminal of the unit (g 1)
Put the other end (discharge) out of the nearest window.
The length of the air exhaust between 550 – 1500mm. Use
the minimum length when working. When mounting, try
and keep the air exhaust hose vertical or horizontal, sloping
up or down. Never operate if the hose is kinked or sagging.
(g2 & 3).
If mounting exhaust duct through a wall, the height of the
hole should be 40 – 130cm.
Before Starting the unit
1. Select a suitable location, with access to a 13amp 230volt
50Hz socket outlet. Plug in and switch on.
2. Install the exible exhaust hose to outside atmosphere.
Note: Step 2 is only required when cooling mode is selected.
3. Connect the pumped condensate drain hose to suitable drain
point or container.
If the display shows fault E4, remove the lower drain plug at the rear of
the base of the unit to drain excess condensate.
Cooling Operation
1. Switch on unit by pressing the Power Button.
2. Press the mode select button until the cooling mode symbol
illuminates on the display panel.
3. Press the Temperature Up / Down buttons to set the desired
room temperature between 15°C – 31°C. After a few seconds
the display will change to show the actual room temperature.
4. Press the Speed button to set the desired fan speed.
Dehumidier Operation
1. Switch on the unit by pressing the Power Button.
2. Press the mode select button until the dehumidifying mode
symbol illuminates on the display panel.
Note the temperature and fan speed will regulate automatically.
Auto Mode
Auto mode will maintain the room temperature at 24°C and
automatically select the fan speed.
Setting Timer ON
With the air conditioner turned , press the timer button and ON
select (with the temp + and temp- buttons) a time the unit is
required to start.
Setting Timer OFF
With the air conditioner turned , press the timer button and ON
select (with the temp+ and temp- buttons) a time the unit is
required to turn OFF.
Mode Temperature / Timer Display Mode Set
Increase / Decrease
Temperature
& Setting
Fan Speed
Cooling Mode Water Full Dehumidier Timer Set
Fig 6
If sleep mode is selected the unit will automatically turn o after 8 hours.
By activating swing mode the air deection lovers will swing 120°.
Fig 1 Fig 2 Fig 3
Fig 4 Fig 5


Product specificaties

Merk: Andrews
Categorie: Airconditioner
Model: Mistral Heat Pump

Heb je hulp nodig?

Als je hulp nodig hebt met Andrews Mistral Heat Pump stel dan hieronder een vraag en andere gebruikers zullen je antwoorden




Handleiding Airconditioner Andrews

Handleiding Airconditioner

Nieuwste handleidingen voor Airconditioner