AMX MXD-2001-PAN Handleiding

AMX Niet gecategoriseerd MXD-2001-PAN

Lees hieronder de 📖 handleiding in het Nederlandse voor AMX MXD-2001-PAN (2 pagina's) in de categorie Niet gecategoriseerd. Deze handleiding was nuttig voor 13 personen en werd door 2 gebruikers gemiddeld met 4.5 sterren beoordeeld

Pagina 1/2
QUICK START GUIDE
MXD-2001-PAN 20.3" Modero X® Series G5 Panoramic Wall Mount Touch Panel
Overview
MXD-2001-PAN 20.3" Modero X Series ® G5 Panoramic Wall Mount Touch Panels feature the
G5 Graphic Engine to provide fast and smooth animations and transitions, as well as the Quad
Core Processor. These panels feature a panoramic capacitive multi-touch screen, and are
hardware-ready for support of Near Field Communication™ (NFC) Technology. The MXD-2001-
PAN is available in Portrait and Landscape layouts:
Product Specifications
MXD-2001-PAN Installation
For more detailed installation instructions including important notes on thermal
concerns with Rack and Wall installations, refer to the X-Series-G5 Touch Panels
MXD/T-1901-PAN & MXD/T-2001-PAN Instruction Manual (available to view/download
from www.amx.com).
Detailed specifications drawings for the MXD-2001-PAN are available to download from
www.amx.com.
The MXD-2001-PAN may be installed directly into a solid surface environment, using either
solid surface screws or the included locking tabs for different mounting options.
Once installed, the panel is contained within a clear outer housing known as the Backbox. The
Backbox is removed to install it into a wall, or when using the optional Rough-In Box
accessory (FG039-15).
Note: For typical mounting surfaces, such as drywall, use the locking tabs as the primary
method for securing the Backbox to the surface. For thin walls or solid surfaces, use mounting
screws (not included).
Installing the MXD-2001-PAN Into a Wall
The MXD-2001-PAN comes with a clear plastic Backbox (FIG. 2) designed to attach the panel
to most standard wall materials. This Backbox has four locking tabs (2 on top, 2 on bottom) to
help lock the Backbox to the wall. These locking tabs are only extended AFTER the Backbox is
inserted into the wall.
When installing the Backbox, make sure that the assembly is in the correct position and
in the correct place. Once the locking tabs are extended and locked into place, removing
the Backbox may be difficult without having access to the back of the wall or causing
damage to the wall.
In order to ensure a stable installation of the MXD-2001-PAN, the thickness of the wall
material must be a minimum of .50 inches (1.27cm) and a maximum of .875 inches
(2.22cm). The mounting surface should also be smooth and flat. The Backbox also has
four slots for accepting the temporary mounting posts mounted on the back of the
device.
Installing the Backbox
Since the cutout for the Backbox is off-center from the edges of the touch panel, use the
included Installation Template (68-5968-01) to ensure proper placement. The template is
marked on one side with directions for both landscape and portrait installations to ensure that
the touch panel and Backbox are properly aligned.
WARNING: Using the Installation template to select the final placement of the Backbox is highly
recommended. The outside edges of the template are the same dimensions as the touch panel,
which allows you to troubleshoot possible conflicts with wall edges, doors, and other potential
obstacles.
1. Prepare the area by removing any screws or nails from the drywall before beginning the
cutout process.
2. After ensuring proper placement, cut out the mounting surface for the Backbox, using
the (included) Installation Template as a guide.
CAUTION: Making sure that the actual cutout opening is slightly smaller than the provided
dimensions is highly recommended. This provides a margin of error if the opening needs to
be expanded. Too little wall material removed is always better than too much.
3. Thread the incoming power and Ethernet wiring from their terminal locations through
the surface opening (see FIG. 4 on reverse). Leave enough slack in the wiring to
accommodate any re-positioning of the panel.
Portrait MXD-2001-PAN-P FG5968-36
Landscape MXD-2001-PAN-L FG5968-37
FIG. 1 MXD-2001-PAN-P/L (PORTRAIT AND LANDSCAPE)
MXD-2001-PAN SPECIF ICATIONS
Dimensions (HWD) Landscape: 9 1/2" x 20 3/8" x 11/16" (242mm x 519mm x 19 mm)
Portrait: 20 3/8" x 9 1/2" x 11/16" (519mm x 242mm x 19mm)
Weight 9.0 lbs (4.08 Kg)
Power
Consumption
Full-On: 35 W (13.5V , 2.6A)
Standby: 7 W (13.5V , 0.52A)
External Power
Supply Required
Requires one of these AMX power sources (not included):
PSR4.4 Power Supply, 4.5A, 3.5 mm Phoenix with Retention Screws
(FG423-46)
PSN4.4 Power Supply, 4.5A, 3.5 mm Phoenix, 13.5V (discontinued)
(FG423-45)
MXA-MPL Modero X Series Multi Preview Live (FG5968-10)
MXA-MP Modero X Series Multi Preview (FG5968-20)
Certifications FCC Part 15 Class B
C-Tick CISPR 22 Class B
CE EN 55022 Class B and EN 55024
CB Scheme IEC 60950-1
• IC
• IEC/EN-60950
UL 60950-1
RoHS/WEEE compliant
Environmental Temperature (Operating): 32°F to 104°F (0°C to 40°C)
Temperature (Storage): 4°F to 140°F (-20°C to 60°C)
Humidity (Operating): 20% to 85% RH
Humidity (Storage): 5% to 85% RH
Power ("Heat") Dissipation:
On: 119.4 BTU/hr
Standby: 23.9 BTU/hr
Included
Accessories
Locking 2-pin Phoenix mate (41-0002-SA)
MXA-USB-C, USB Port Cover Kit (FG5968-18)
MXA-CLK, Modero X Series Cleaning Kit (FG5968-16)
Installation Template 20.3" (68-5968-01)
Sleep ButtonNFC Sensor
Sleep
NFC
Button
Sensor
MXD-2001-PAN-P
MXD-2001-PAN-L
FIG. 2 MXD-2001-PAN BACKBOX
FIG. 3 MXD-2001-PAN (LANDSCAPE)
FIG. 4 MXD-2001-PAN BACKBOX INSTALLATION (LANDSCAPE)
Locking Tabs
Locking Tabs
Temporary Mounting Posts
Temporary Mounting Posts
Backbox
Backbox knockouts (X8) Locking tabs (X4)
8X Knock Outs
Remove For Cable
Routing As Needed Mounting screws
placement (optional)
Wall
4X Installation Clamp
for Wall Thickness
.37 [12.01] to .98 [25.0]
Cables Routed to
Wall Opening
© 2015 Harman. All rights reserved. Modero X and Modero X Series, AMX, AV FOR AN IT WORLD, and HARMAN, and their respective logos are
registered trademarks of HARMAN. Oracle, Java and any other company or brand name referenced may be trademarks/registered trademarks
of their respective companies.
AMX does not assume responsibility for errors or omissions. AMX also reserves the right to alter specifications without prior notice at any time.
The AMX Warranty and Return Policy and related documents can be viewed/downloaded at www.amx.com.
3000 RESEARCH DRIVE, RICHARDSON, TX 75082 AMX.com | 800.222.0193 | 469.624.8000 | +1.469.624.7400 | fax 469.624.7153
AMX (UK) LTD, AMX by HARMAN - Auster Road, Clifton Moor, York, YO30 4GD United Kingdom • +44 1904-343-100 • www.amx.com/eu/
93-5968-36 REV: E
Last Revised: 6/22/2015
4. Remove any knockouts as needed on either long dimension of the Backbox to facilitate
incoming wiring and pull the wiring through the resultant holes.
5. Push the Backbox into the wall opening. Insure that the locking tabs lie flush against the
Backbox.
6. Extend the locking tabs on the sides of the Backbox by tightening the screws inside the
box until snug. Apply enough pressure to the screw head to keep the box flush with the
wall: this ensures that the locking tabs will tighten up against the inside of the wall.
7. For additional strength, #4 mounting screws (not included) may be secured through the
mounting holes located at the left and right sides of the panel (FIG. 4).
In order to prevent damage to the touch panel, make sure that these are flush with the
Backbox.
8. Insert each connector into its corresponding location along the back of the device.
9. Test the incoming wiring by attaching the panel connections to their terminal locations
and applying power. Verify that the panel is receiving power and functioning properly to
prevent repetition of the installation.
Remove power before continuing with the installation.
Note: Do not disconnect the cables from the touch panel. The panel must be installed with
the cables attached before being inserted into the drywall.
Note: Configurations that use the limited access USB port on the side of the connector
box may require a right angle mating connector (not included).
10. Insert the four temporary mounting posts of the panel into the openings on the Backbox
and slide the panel onto the Backbox. This will temporarily hold the panel during the rest
of the installation (FIG. 5).
WARNING: When installing the panel, do NOT press on or near the center of the panel. Too
much stress at the center may damage the touch screen surface. When installing the
panel, pressure should be applied toward the ends of the panel ONLY.
11. Use the six provided screws, three at each end, to secure the touch panel to the Backbox
(FIG. 5). Use only the provided screws, as other screws may damage the touch panel.
12. Snap the side covers onto each end of the touch panel.
13. Reconnect the terminal Ethernet and USB to their respective locations on either the
Ethernet port or NetLinx Master.
Panel Connectors and Wiring
Connectors are located on the underside of the MXD-2001-PAN. The Micro-USB port is used
for camera video output. A second, limited access USB port is accessible on the back side of
this cover.
Wiring Guidelines
The MXD-2001-PAN uses a 13.5V -compliant power supply to provide power to the panel
via the 2-pin 3.5 mm captive wire PWR connector. Use the previously provided power
requirement information to determine the power draw. The incoming PWR and GND wires from
the power supply must be connected to the corresponding locations within the PWR
connector.
Note: Apply power to the panel only after installation is complete. Connecting power to the
MXD-2001-PAN should be done using the included 2-pin 3.5mm captive wire connector included
with the device. This connector uses retaining screws (instead of the pins on each side of
standard captive wire connectors); using excessive force to insert a standard captive wire
connector may damage the device.
Wiring a Power Connection
To use the 2-pin 3.5 mm captive wire connector with a 13.5V -compliant power supply, the
incoming PWR and GND wires from the external source must be connected to their
corresponding locations on the connector (FIG. 6). The connector uses locking screws to
insure a connection to the device, so make sure to insert and tighten the screws before
applying power.
1. Insert the PWR and GND wires into the terminal end of the 2-pin 3.5 mm captive wire
connector cable. Match the wiring locations of the +/- on both the power supply and the
terminal connector.
2. Tighten the clamp to secure the two wires. Do not tighten the screws excessively; doing
so may strip the threads and damage the connector.
3. Verify the connection of the 2-pin 3.5 mm captive wire connector to the external
13.5V compliant power supply and apply power.
Powering On/Off X Series G5 Panels
G5 touch panels may be powered on by touching and holding the Sleep button. To power off
the panel, press and hold the Sleep button, and select Power Off on the on-screen menu.
Conf iguration and Programming
G5 touch panels are equipped with a Settings menu that provides the ability to configure
various features on the panels. To access the Settings menu, press and hold the Sleep button,
and select Settings.
Note: Information on the Settings menu, panel configuration, and programming is provided in
the Modero X Series G5 Programming Guide, available at www.amx.com.
Setting the Panel’s Device Number and Device Name
1. In the Settings menu, select NetLinx. This opens a password keypad.
2. Enter the panel password into the keypad (the default is ) and select 1988 OK to access
the NetLinx page.
3. Press Device Number to open the NetLinx editing window.
4. Enter a unique Device Number assignment for the panel and press OK.
5. Enter a unique Device Name assignment for the panel and press OK.
Conf iguring the Panel’s IP Address
These steps configure the panel to communicate with a network; it is still necessary to
connect to the NetLinx Master (see Connecting to a NetLinx Master below).
Network Communication via DHCP
1. In the Ethernet page, press DHCP/Static field to open the DHCP/Static window. Note
that DHCP is the default setting.
2. Select Host Name, enter the new host name
3. Press OK to save changes.
Network Communication via Static Address
1. In the Ethernet page, press DHCP/Static to open the DHCP/Static window.
2. Select Static to open the Static IP window.
3. Press any field to open a keypad or keyboard (depending on the f ield), and enter the
appropriate network address information.
4. Press OK to save your changes and return to the Ethernet page.
Connecting to a NetLinx Master
To establish the type of connection to make between the panel and the NetLinx Master:
1. In the NetLinx page, press Mode to choose the connection mode (URL, Listen or Auto):
2. If password security is enabled on the target Master, enter the Username and Password:
a. Select Username to open the NetLinx window.
b. Enter the Username and Password required by the Master.
c. Press OK to save changes and return to the NetLinx page.
Related Software and Additional Documentation (at www.amx.com
Programming the Modero X Series G5 touch panels requires the use of the latest
versions of NetLinx Studio and TPDesign5, both available to download at www.amx.com.
Refer to the NetLinx Studio and TPDesign5 online help for information.
For additional information on the MXD-2001-PAN, refer to the X-Series-G5 Touch Panels
MXD/T-1901-PAN & MXD/T-2001-PAN Instruction Manual.
For detailed information on the Settings menu as well programming information and
instructions on upgrading firmware, refer to the Modero X Series G5 Programming Guide.
FIG. 5 MXD-2001-PAN INSTALLATION (LANDSCAPE)
Wall
Side cover
4X Mounting posts
4X Mounting post openings
Side
cover
6X 4-40 X 1/4" LONG FLAT HEAD
TORQUE TO 5±.2 IN LBS
FIG. 6 NETLINX POWER CONNECTOR WIRING DIAGRAM
CONNECTION MODES
Mode Description Procedures
URL The device connects to the
target Master’s IP address via a
TCP connection.
1) Select URL in the Mode menu.
2) Enter the Master IP/URL, Master Port Number,
and Username/Password (if required by the
Master).
3) Press OK to save changes.
Listen This mode allows the panel to
“listen” for the Master’s
communication signals.
Note that in this mode, the
System Number and Master IP/
URL fields are read-only.
1) Select Listen in the menu.Mode
2) Confirm the panel’s IP address is on the
Master’s URL list (via NetLinx Studio).
3) Press OK to save changes.
Note: The Host Name (set on the Ethernet page),
can be used to locate the panel on the Master
(particularly useful for DHCP connections where
the IP address can change).
Auto Use this mode when both the
panel and the NetLinx Master
are on the same Subnet.
1) Select Auto in the Mode menu.
2) Enter the System Number and Username and
Password (if applicable).
3) Press OK to save changes.
PWR +
GND -
To the Touch Panel Power Supply


Product specificaties

Merk: AMX
Categorie: Niet gecategoriseerd
Model: MXD-2001-PAN

Heb je hulp nodig?

Als je hulp nodig hebt met AMX MXD-2001-PAN stel dan hieronder een vraag en andere gebruikers zullen je antwoorden




Handleiding Niet gecategoriseerd AMX

Handleiding Niet gecategoriseerd

Nieuwste handleidingen voor Niet gecategoriseerd