Alula RE619 Handleiding


Lees hieronder de 📖 handleiding in het Nederlandse voor Alula RE619 (2 pagina's) in de categorie Niet gecategoriseerd. Deze handleiding was nuttig voor 43 personen en werd door 2 gebruikers gemiddeld met 4.5 sterren beoordeeld

Pagina 1/2
Use the panel installation guide to verify proper system setup.
The RE619 Home Disaster is an integrated environmental
sensor that detects ood and extreme temperature
conditions.
Features
•Titanium probes for unmatched corrosion immunity
•Detects ood, freeze, and heat conditions
•Secure encrypted wireless transmissions
•5-year warranty
Enroll by placing the panel into wireless enrollment mode,
and then sending an enrollment signal from the sensor.
Alternatively, the sensor can be enrolled by scanning its
bar code using the Connect+ Installer App or by entering
its 8-character serial number on the interactive service
provider’s web portal. NOTE, freeze and heat inputs must
be enabled as additional zones using the installer app or
the interactive service provider’s web portal.
Install by placing the remote ood probe in the location
requiring ood or leak detection. If desired, the ood
probe can be screwed to the oor or baseboard. Next,
mount the sensor to the wall using the mounting screw
locations. Finally, connect the ood probe wires to the
sensor’s terminal blocks.
Detects water pooled under the sensor and reports extreme
temperature conditions.
Default Temperature Trip Points
•Heat alarms when over 100°F (38°C)
•Heat restores when under 97°F (36°C)
•Freeze alarms when under 45°F (7°C)
•Freeze restores when over 48°F (9°C)
RE619 Home Disasterâ„¢
Connect+â„¢ Encrypted
I
N
S
T
A
L
L
G
U
I
D
E
I
Mounting
Screw
Holes
Wire
Entry
Hole
Sending an Enrollment Signal
•Remove the battery tab and remove the cover
to trip the tamper
IC NOTICE
This device complies with Industry Canada license-exempt RSS
standard(s). Operation is subject to the following two conditions:
(1) This device may not cause interference, and
(2) This device must accept any interference, including interference
that may cause undesired operation of the device.
Le présent appareil est conforme aux cnr d’Industrie Canada
applicables aux appareils radio exempts de licence. L’exploitation
est autorisée aux deux conditions suivantes:
(1) L’appareil ne doit pas produire de brouillage, et
(2) L’utilisateur de l’appareil doit accepter tout brouillage
radioélectrique subi, même si le brouillage est susceptible d’en
compromettre le fonctionnement.
IC: 8310A-RE301
FCC NOTICE
This device complies with Part 15 of the FCC rules. Operation is
subject to the following two conditions:
(1) This device may not cause harmful interference.
(2) This device must accept any interference that may be received,
including interference that may cause undesired operation.
Changes or modications not expressly approved by Alula could void
the user’s authority to operate this equipment.
FCC ID: U5X-RE301
WARRANTY
Alula will replace products that are defective in their rst ve (5)
years.
TRADEMARKS
Alula and Connect+ are trademarks owned by Alula Holdings, LLC.
Panasonic is a registered trademark owned by Panasonic
Corporation.
Pro Tips
Both titanium probes must be in the same puddle for the sensor to detect water.
A second probe can be added for additional protection in another location. Do not
install more than two probes.
The ood probe can be mounted in a sump tank at the desired height to provide pump
failure notication.
47-0021-08 • REV E • 2019-02-07
Tech Support Line • (888) 88-ALULA • (888) 882-5852
alula.net
Physical
Housing Dimensions
Weight with Battery
Mounting Fastener
3.25 x 1.40 x 1.05 inches (8.3 x 3.6 x 2.7 cm)
1.90 ounces (54 grams)
#4 or #6 screws (not provided)
Environmental
Operating Temperature
Maximum Humidity
32 to 120 °F (0 to 49 °C)
85% non-condensing relative humidity
Sensor Specications
Frequency
Replacement Battery
Nominal Battery Life
Battery Voltage
Current Draw
Transmitted Indications
Temperature Accuracy
433.92 MHz
One Panasonic® CR123A
8 to 10 years
3.0 VDC (Nominal), 2.2 VDC (Low)
20 mA (Maximum), 0.6 uA (Quiescent)
Flood, Freeze, Heat, Tamper, Low Battery, Supervision
+/- 2°C
Certication
RE619 FCC, IC
Specications subject to change without notice.
Specications
00
00


Product specificaties

Merk: Alula
Categorie: Niet gecategoriseerd
Model: RE619

Heb je hulp nodig?

Als je hulp nodig hebt met Alula RE619 stel dan hieronder een vraag en andere gebruikers zullen je antwoorden




Handleiding Niet gecategoriseerd Alula

Alula

Alula RE118 Handleiding

2 Februari 2024
Alula

Alula RE605 Handleiding

2 Februari 2024
Alula

Alula RE619 Handleiding

2 Februari 2024
Alula

Alula RE305 Handleiding

2 Februari 2024
Alula

Alula RE219 Handleiding

2 Februari 2024
Alula

Alula RE318 Handleiding

2 Februari 2024
Alula

Alula RE105 Handleiding

2 Februari 2024
Alula

Alula RE205 Handleiding

2 Februari 2024
Alula

Alula RE218 Handleiding

2 Februari 2024
Alula

Alula RE119 Handleiding

2 Februari 2024

Handleiding Niet gecategoriseerd

Nieuwste handleidingen voor Niet gecategoriseerd