Alula RE318 Handleiding


Lees hieronder de 📖 handleiding in het Nederlandse voor Alula RE318 (2 pagina's) in de categorie Niet gecategoriseerd. Deze handleiding was nuttig voor 37 personen en werd door 2 gebruikers gemiddeld met 4.5 sterren beoordeeld

Pagina 1/2
Flood and Temp Sensor is an integrated environmental sensor.
It detects ood conditions and reports extreme temperatures.
Features
• Titanium probes for unmatched corrosion immunity
• IP67 rated waterproof enclosure
• GORE
ÂŽ
vent to prevent seal failure
• 5 year warranty
Enroll the ood zone by placing the panel into wireless
enrollment mode and removing the battery tabs or tampering
the sensor. The freeze and heat zones are disabled by default.
To activate and enroll the freeze and heat zones, remove the
sensor cover and use a wire or paper clip to short the desired
outer terminal to the center terminal. To maximize battery life,
only activate the zones being used.
ESN ID Conguration
• Flood ID is the serial number shown on the device.
• Freeze ID is the serial number with last digit
replaced with a 1.
• Heat ID is the serial number with last digit replaced
with a 2.
Install by placing the sensor in the location requiring ood or
temperature detection. If desired, the wall clip can be used to
secure the sensor.
Optional Screw Mounting
• Remove the wall clip from the sensor’s body.
• Secure the clip to a wall, baseboard or cupboard
using a #6 screw.
• Slide the sensor’s body down onto the wall clip until
it snaps into place.
Detects water pooled under the sensor and reports extreme
temperature conditions.
Temperature Trip Points
• Heat alarms when over 100°F (38°C)
• Heat restores when under 97°F (36°C)
• Freeze alarms when under 45°F (7 C)
• Freeze restores when over 48°F (9°C)
To replace the batteries, insert a at blade screwdriver into
the front slot and twist. Slide both old batteries out and the
new batteries in. To reinstall the cover, align the rear latches
and roll the cover forward until it snaps into place.
I
N
S
T
A
L
L
G
U
I
D
E
I
Front slot
Mounting Screw Hole
Wall Clip
Verify proper enrollment and operation using your control panel’s installation manual.
RE318 Flood & Temp Sensor
DSCÂŽ Compatible
Resolution Compatibles
47-0028-03 • RevB • 2018-03-28
Tech Support Line • (888) 88-ALULA • (888) 882-5852
alula.net
WARRANTY
Alula will replace products that are defective in their rst ve (5)
years.
IC NOTICE
This device complies with Industry Canada license-exempt RSS
standard(s). Operation is subject to the following two conditions:
(1) This device may not cause interference, and
(2) This device must accept any interference, including interference
that may cause undesired operation of the device.
Le présent appareil est conforme aux cnr d’Industrie Canada
applicables aux appareils radio exempts de licence. L’exploitation
est autorisĂŠe aux deux conditions suivantes:
(1) L’appareil ne doit pas produire de brouillage, et
(2) L’utilisateur de l’appareil doit accepter tout brouillage
radioélectrique subi, même si le brouillage est susceptible d’en
compromettre le fonctionnement.
IC: 8310A-RE318
FCC NOTICE
This device complies with Part 15 of the FCC rules. Operation is
subject to the following two conditions:
(1) This device may not cause harmful interference.
(2) This device must accept any interference that may be received,
including interference that may cause undesired operation.
Changes or modications not expressly approved by Alula could void
the user’s authority to operate this equipment.
FCC ID: U5X-RE318
TRADEMARKS
Alula is a trademark owned by Alula Holdings, LLC.
DSC is a trademark owned by TYCO Safety Products Canada LTD.
Alula products will function with DSC systems. However, no Alula
product is produced by, endorsed by, nor is ofcially associated with
DSC. Alula recommends verifying proper enrollment and operation,
per control panel installation instructions, at installation.
Pro Tips
The cover can be removed without removing the wall clip.
Both titanium probes must be in the same puddle for the sensor to detect water.
Tamper detection depends on how the sensor is installed.
• Sensor secured to wall: Tamper is indicated when lifted off the clip.
• Sensor NOT secured to wall: Tamper is indicated when the cover is removed.
When changing the batteries replace both with new batteries.
Specications
Physical
Housing Dimensions
Weight with Batteries
Mounting Fastener
2.43 x 2.48 x 1.17 inches (6.2 x 6.3 x 3.0 cm)
1.34 ounces (38 grams)
#6 screw (not provided)
Environmental
Operating Temperature
Maximum Humidity
Water Resistance
32°F to 120°F (0°C to 49°C)
85% non-condensing relative humidity
IP67 rated (Waterproof for over 30 minutes at 1 meter depth)
Sensor Specications
Frequency
Replacement Batteries
Nominal Battery Life
Battery Voltage
Current Draw
Transmitted Indications
Temperature Accuracy
433.92 MHz
Two Panasonic CR2032
10 years
3.0 VDC (Nominal) 2.3 VDC (Low)
20 mA (Maximum) 0.5 uA (Quiescent)
Cover Tamper, Wall Tamper, Low Battery, Supervision
+/- 2°C
Certication
RE318 FCC, IC
Specications subject to change without notice.


Product specificaties

Merk: Alula
Categorie: Niet gecategoriseerd
Model: RE318

Heb je hulp nodig?

Als je hulp nodig hebt met Alula RE318 stel dan hieronder een vraag en andere gebruikers zullen je antwoorden




Handleiding Niet gecategoriseerd Alula

Alula

Alula RE118 Handleiding

2 Februari 2024
Alula

Alula RE605 Handleiding

2 Februari 2024
Alula

Alula RE619 Handleiding

2 Februari 2024
Alula

Alula RE305 Handleiding

2 Februari 2024
Alula

Alula RE219 Handleiding

2 Februari 2024
Alula

Alula RE318 Handleiding

2 Februari 2024
Alula

Alula RE105 Handleiding

2 Februari 2024
Alula

Alula RE205 Handleiding

2 Februari 2024
Alula

Alula RE218 Handleiding

2 Februari 2024
Alula

Alula RE119 Handleiding

2 Februari 2024

Handleiding Niet gecategoriseerd

Nieuwste handleidingen voor Niet gecategoriseerd