Bekijk gratis de handleiding van Alula RE305 (2 pagina’s), behorend tot de categorie Niet gecategoriseerd. Deze gids werd als nuttig beoordeeld door 183 mensen en kreeg gemiddeld 4.6 sterren uit 92 reviews. Heb je een vraag over Alula RE305 of wil je andere gebruikers van dit product iets vragen? Stel een vraag
Pagina 1/2

The Temperature Sensor is used to detect freeze and
overheat conditions. The sensor will alarm when the
temperature trip points are reached.
Features
• Indicates freeze and overheat warnings
• Industry-leading wireless range and battery life
• Secure encrypted wireless transmissions
• 5-year warranty
Enroll the freeze input (ID ending in 0) by placing the
panel into wireless enrollment mode and then sending
an enrollment signal from the sensor.
Options for sending an Enrollment Signal
• Remove the battery tab and cover to trip
tamper.
Overheat inputs and reed zones must be enabled to
function. Activate only as needed in order to extend
battery life.
To activate and enroll an overheat input (ID ending in
1):
• Remove magnet from reed switch
• Hold down tamper and install battery
Install by mounting the sensor in the desired location
using two #4 or #6 screws. An optional cover-securing
screw is included. Alternatively, the sensor can also be
installed using 3M™ VHB™ tape.
Freeze Heat or alarms are transmitted when the
temperature trip points are reached.
Temperature Trip Points
• Heat alarms when over 100°F (38°C)
• Heat restores when under 97°F (36°C)
• Freeze alarms when under 45°F (7°C)
• Freeze restores when over 48°F (9°C)
Use the panel installation guide to verify proper system setup.
Mounting Screw Holes
RE305 Temperature Sensor
DSC® Compatible
I
N
S
T
A
L
L
G
U
I
D
E
I
Cover-Securing Screw Hole
Resolution Compatibles

WARRANTY
Alula will replace all non-portable products that are defective in
their rst ve (5) years, and all portable products that are defective
in their rst two (2) years.
IC NOTICE
This device complies with Industry Canada license-exempt RSS
standard(s). Operation is subject to the following two conditions:
(1) This device may not cause interference, and
(2) This device must accept any interference, including interference
that may cause undesired operation of the device.
Le présent appareil est conforme aux cnr d’Industrie Canada
applicables aux appareils radio exempts de licence. L’exploitation
est autorisée aux deux conditions suivantes:
(1) L’appareil ne doit pas produire de brouillage, et
(2) L’utilisateur de l’appareil doit accepter tout brouillage
radioélectrique subi, même si le brouillage est susceptible d’en
compromettre le fonctionnement.
IC: 8310A-RE305
FCC NOTICE
This device complies with Part 15 of the FCC rules. Operation is
subject to the following two conditions:
(1) This device may not cause harmful interference.
(2) This device must accept any interference that may be received,
including interference that may cause undesired operation.
Changes or modications not expressly approved by Alula could void
the user’s authority to operate this equipment.
FCC ID: U5X-RE305
TRADEMARKS
Alula is a trademark owned by Alula Holdings, LLC.
“DSC” is a trademark owned by TYCO Safety Products Canada LTD.
Alula products will function with DSC systems. However, no Alula
product is produced by, endorsed by, or is ofcially associated with
DSC. Alula recommends verifying proper enrollment and operation,
per control panel installation instructions, at installation.
3M and VHB are trademarks owned by 3M Company.
Panasonic is a registered trademark owned by Panasonic
Corporation.
47-0018-03 • REV B • 2019-02-20
Tech Support Line • (888) 88-ALULA • (888) 882-5852
alula.net
Specications
Specications subject to change without notice
Physical
Housing Dimensions
Weight with Battery
Mounting Fastener
3.30 x 1.40 x 1.10 inches (8.3 x 3.6 x 2.7 centimeters)
1.90 ounces (54 grams)
#4 or #6 screws (not provided)
Environmental
Operating Temperature
Maximum Humidity
0°F to 120°F (0°C to 49°C)
85% non-condensing relative humidity
Sensor Specications
Frequency
Replacement Battery
Nominal Battery Life
Battery Voltage
Current Draw
Transmitted Indications
433.92 MHz
One Panasonic® CR123A
10 years
3.0 VDC (Nominal), 2.2 VDC (Low)
20 mA (Maximum), 0.6 uA (Quiescent)
Cover Tamper, Low Battery, Supervision
Certication
RE305 FCC, IC
Pro Tips
3M™ VHB™ Tape works great if the surface is properly prepared and rm pressure is
applied for over 10 seconds.
Surface Preparation
• Clean the surface
• Ensure the mounting surface temperature is above 50°F
02
Product specificaties
Merk: | Alula |
Categorie: | Niet gecategoriseerd |
Model: | RE305 |
Heb je hulp nodig?
Als je hulp nodig hebt met Alula RE305 stel dan hieronder een vraag en andere gebruikers zullen je antwoorden
Handleiding Niet gecategoriseerd Alula
2 Februari 2024
2 Februari 2024
2 Februari 2024
2 Februari 2024
2 Februari 2024
2 Februari 2024
2 Februari 2024
2 Februari 2024
2 Februari 2024
2 Februari 2024
Handleiding Niet gecategoriseerd
- Bartscher
- Finder
- Newland
- SainSmart
- Osprey
- Fisher Paykel
- Cardiostrong
- HEDD
- Polk
- Nuna
- Schwinn
- Celestron
- Gaggenau
- Itho
- Fannova
Nieuwste handleidingen voor Niet gecategoriseerd
2 Augustus 2025
2 Augustus 2025
2 Augustus 2025
2 Augustus 2025
2 Augustus 2025
2 Augustus 2025
2 Augustus 2025
2 Augustus 2025
2 Augustus 2025
1 Augustus 2025