Air King 9155 Handleiding


Lees hieronder de 📖 handleiding in het Nederlandse voor Air King 9155 (8 pagina's) in de categorie Ventilator. Deze handleiding was nuttig voor 12 personen en werd door 2 gebruikers gemiddeld met 4.5 sterren beoordeeld

Pagina 1/8
OPERATING INSTRUCTIONS & PARTS MANUAL
16" REVERSIBLE WINDOW FAN 16" (40,64 cm)
Model 2EJR6J/9155J
Motor 120V, 60 Hz ......................................................................
Blade size 16" (40,6 cm) ..............................................................
Speeds 3 intake, 3 exhaust ...................................................................
Control Rotary switch ...................................................................
Approvals ETL Listed. Close mesh fan guard ................................
meets OSHA requirements.
Specifications
Description
The Air King window fan features three intake and three exhaust ®
speeds and fits windows 26 1/2" (67,3 cm) to 34 1/2" (87,6 cm) wide
to 22" (55,9 cm) high. The adjustable side panels are designed to
accommodate fan mounting either inside or outside interior window
trim. The 16" (40,64 cm), 3-paddle fan blade is driven by a perma-
nently prelubricated motor, 6 foot (1,8 m), 18/3 cord set.
Rev. K 11/17 12082048A
MODEL 2ERJ6J/9155J
SPEED HIGH MED LOW
CFM 2210 1840 1325
M3/s 1.04 0.87 0.63
RPM 1425 1180 970
Amps 0.80 0.60 0.55
Watts 90 70 65
dB A 62 51 48
READ AND SAVE THESE INSTRUCTIONS
READ CAREFULLY BEFORE ATTEMPTING TO ASSEMBLE,
INSTALL, OPERATE OR MAINTAIN THE PRODUCT DESCRIBED.
PROTECT YOURSELF AND OTHERS BY OBSERVING ALL SAFETY
INFORMATION. FAILURE TO COMPLY WITH INSTRUCTIONS COULD RE-
SULT IN PERSONAL INJURY AND/OR PROPERTY DAMAGE!
Rev. K 11/17 22082048A
SAVE THESE INSTRUCTIONS
IMPORTANT SAFETY INFORMATION
When using electrical appliances, basic precautions should always be followed to reduce
the risk of fire, electrical shock and injury to persons, including the following:
Read all instructions before using this Fan.
TO REDUCE THE RISK OF FIRE, ELECTRICAL SHOCK OR PERSONAL INJURY, ALWAYS
FOLLOW THESE IMPORTANT SAFETY INSTRUCTIONS AND WARNINGS:
DO NOT use this fan to ventilate areas where flammable liquids or vapors are used, stored or are present, including paints, gaso-
line, varnishes, floor refinishing products or solvents. ALWAYS read and follow all warnings and instructions on the containers for
these products!
ALWAYS be sure the plug fits tightly into the outlet. When plugs fit loosely into outlets, they may slip partially out of the outlet and
create a poor connection. This may cause outlets to overheat and create a potential fire hazard. Outlets in this condition should be
replaced by a qualified electrician.
ALWAYS unplug the power cord when servicing, cleaning or moving the Fan. DO NOT use the ON/OFF switch as the sole means of
disconnecting power. NEVER leave children unattended when the Fan is on or plugged in. ALWAYS turn off and unplug the Fan when
not in use.
BE CERTAIN that the power source for the Fan is 120V AC. DO NOT plug the Fan into 240V or other power source.
The Blue Plugâ„¢ on your AirKing fan is a safety feature. It contains a non-replaceable safety device (fuse) that should not be removed or
tampered with. To reduce the risk of fire, electric shock and personal injury, attempt to remove, replace, repair or tamper with DO NOT
the originally supplied plug. If the Fan has stopped functioning, it may be due to the safety device incorporated in this plug.
The power cord is equipped with a three-prong grounded plug that must be inserted into a matching receptacle. Under no circum-
stances should the grounding prong be cut off the plug. Where a two-prong wall receptacle is encountered, it must be replaced
with a properly grounded three-prong receptacle installed in accordance with the National Electrical Code (NEC) and all applicable
local codes and ordinances. This work must be done only by a qualified electrician, using copper wire only.
DO NOT USE A THREE-PRONG TO TWO-PRONG ADAPTER. IMPROPER CONNECTION MAY CREATE THE RISK OF ELECTRI-
CAL SHOCK. USE OF SUCH ADAPTERS IS NOT PERMITTED IN CANADA.
• AVOID the use of extension cords, power strips, power taps, outlet style air fresheners or other cord connected device, as these de-
vices may overheat and cause a fire hazard.
•DO NOT route power cord under rugs, carpets, runners or furniture. This may damage the cord or cause it to overheat creating a fire hazard.
•ALWAYS place the Fan on a stable, flat, level surface while in operation to prevent the Fan from overturning.
•NEVER insert or allow fingers or objects to enter grill openings while Fan is in operation or injury and/or damage to the Fan may occur.
• block, cover or obstruct air flow to or from the fan while in operation.DO NOT
• use this Fan outdoors or near water or wet locations such as a bath tub, pool or hot tub. Use of this Fan in a wet location may DO NOT
create a shock hazard.
• run cord under carpeting. Do not cover cord with throw rugs, runners, or similar coverings. Do not route cord under furniture or DO NOT
appliances. Arrange cord away from traffic area and where it will not be tripped over.
• use a single extension cord to operate more than one Fan or other electrical device.NEVER
• use this Fan if it has been damaged or is not functioning properly. DO NOT
•THIS FAN DOES NOT MEET THE REQUIREMENTS OF NEC ARTICLE 547-7 (2008).This Fan is not suitable for use in agricultural facili-
ties including areas where livestock, poultry or other animals are confined. Please refer to National Electric Code (NEC) Article 547-7
(2008), or applicable state or local codes or standards relating to electrical requirements for agricultural buildings.
•THIS FAN DOES NOT MEET THE REQUIREMENTS OF NEC ARTICLE 500 (2008).This Fan is not suitable for use in hazardous
locations. Please refer to National Electric Code (NEC) Article 500 or applicable state or local codes or standards relating to electrical
requirements for hazardous locations.
CAUTION
Rev. K 11/17 2082048A3
MODEL 2EJR6J/9155J
1. Mark screw locations on
inside edges of window trim
using enclosed template as
shown in illustration.
2. Drive 4 screws "A" into trim.
DO NOT TIGHTEN FLUSH.
Leave
1/8" (3.2 mm) space between
screw heads and window trim.
Figure 3
METHOD B: (Inside of Trim)
Tools Required: Hardware Provided:
Screwdrivers Four - #8 x 3/4" slotted head screws
Installation
The large number of window styles and types makes it impossible
to describe one universal installation procedure. The methods
outlined below are recommended as being well-suited for most
common styles of double-hung windows. Whichever method you
choose should allow the window to be closed easily for security
and protection of home furnishings against the weather. Refer to
illustrations while following Methods A or B below.
3. With side panel in posi-
tion, mark screw loca-
tions at top of slot "C"
and drive in the 4 wood
screws "A" (provided)
until tight.
4. Tighten 4 screws "B" in
fan housing to complete
installation.
Figure 2
2. Rest fan on window sill with flange on side panels over trim. Push in
side panels tight against outer edge of trim.
Figure 1
1. Loosen screws "B"
and extend side pan-
els to clear the outer
edge of trim on each
side of window.
METHOD A: (Outside of Trim)
Tools Required: Hardware Provided:
Screwdrivers Four - #8 x 3/4" slotted head screws
4. Mount fan in window
by engaging slots "C"
with screws "A" on
inside edge of trim.
Lower fan on screws
"A" until it rests on
window sill or sash
moulding.
Figure 5
5. Tighten screw "B" on
housing to secure
fan in position.
3. Loosen 4 screws "B"
and entend panels
on each side of
housing until the fan
fits snugly between
right and left window
trim.
Figure 4
Figure 6
Operation
This Air King® window fan is powered by a durable electrically-reversible
3 speed split capacitor motor. (Hi, Medium, and Low speed settings are
available for both intake and exhaust mode.) The motor control switch
is conveniently located on the motor cover. Adjust knob to direction and
speed desired.
MAINTENANCE
WARNING: ALWAYS UNPLUG THE CORD
BEFORE MOVING OR SERVICING THE FAN.
WARNING: DO NOT IMMERSE FAN IN WATER!
CLEANING: Use a soft cloth moistened with a mild
soap solution, such as liquid dish washing detergent.
Dry ALL PARTS COMPLETELY before reassembling.
After any maintenance or servicing, COMPLETELY
REASSEMBLE unit as described in this instruction
manual before reconnecting to the power supply.
CAUTION: Do not use gasoline, benzine, thin-
ner, harsh cleaners, etc. as they will damage
the Fan. NEVER use ALCOHOL OR SOLVENTS.
LUBRICATION: Precision bearings are sealed at the
factory for life and will not require any further lubrication.
STORAGE: Store the Fan, with these instructions, in a cool, dry place.
DISPOSITION: Corrugated packaging materials are recyclable. For
environmentally responsible disposal of this product, contact your
local waste service provider or visit www.1800recycling.com®.
1/8" (3.2mm)
B
B
C
A
Slot
C
B
B
Slot
C
B
B
Slot
B
B
TEMPLATE
A


Product specificaties

Merk: Air King
Categorie: Ventilator
Model: 9155

Heb je hulp nodig?

Als je hulp nodig hebt met Air King 9155 stel dan hieronder een vraag en andere gebruikers zullen je antwoorden




Handleiding Ventilator Air King

Handleiding Ventilator

Nieuwste handleidingen voor Ventilator