Bekijk gratis de handleiding van Aiphone IXW-HWCBP (4 pagina’s), behorend tot de categorie Intercomsysteem. Deze gids werd als nuttig beoordeeld door 17 mensen en kreeg gemiddeld 4.3 sterren uit 2 reviews. Heb je een vraag over Aiphone IXW-HWCBP of wil je andere gebruikers van dit product iets vragen? Stel een vraag

Pagina 1/4
IXW-HWCBP
Hand Wave Call Button and Surface Mount Box
IXW-HWCBP includes a touchless switch attached to a mounting plate, a PS-POE, and the SBX-2G/A
surface mount box. This device can be connected to any IX Series door station with a trigger input and a PoE
passthrough. It will place calls to the programmed station without having to touch the call button. The touchless
switch is powered by the PS-POE. The switch’s contact output will trigger a contact input on the door station. The
contact input will need to be programmed and assigned to a calling group. This instruction manual will show how
to connect the IXW-HWCBP to the door station and program the door station for contact input calling.
Wiring
1 of the IX Series door station. LAN 2 connects to the included PS-POE. Connect the power output of the
PS-POE to the red (+VDC) and black (Gnd) wires of the touchless switch. Connect the green (N/O) and yellow
(Common) wires of the touchless switch to contact input 1 on the IX Series door station (brown/blue wires on
CN2).
- Instructions -
Specications
Dimensions: 4-¹³" H x 4-" W x 4" D
Package Contents
Qty 1 Panel with touchless switch
Qty 1 SBX-2G/A
Qty 1 PS-POE
Qty 4 speed nuts for panel mounting
Qty 4 screws for panel mounting
Qty 1 three-foot patch cable
Installation
1. Secure SBX-2G/A to wall
2. Connect included patch cable, power wires, and
a ground wire to PS-POE and place unit
inside the SBX-2G/A
3. Connect included patch cable to LAN 2 of IX
series door station
3. Connect touchless switch to input of IX series
door station and PS-POE
- Green (N.O.) to Brown (CN2 of IX-DV)
- Yellow (Common) to Blue (CN2 of IX-DV)
- White (N.C.) not used
- Red (+VDC) to + of PS-POE
- Black (GND) to - of PS-POE
4. Secure switch panel to SBX-2G/A
Back View
PoE+ Switch
Cat-5e / Cat-6
PS-POE
PoE IN
- +
N.C. (not used)
Red = +VDC
Black =Gnd
,;'9
IX-DV
IXW-HWCBP
If a PoE passthrough is
not available, connect
the PS-POE directly to
the PoE switch
Patch cable supplied
IXW-HWCBP Instr
0321
Aiphone Corporation
www.aiphone.com
800-692-0200

Beoordeel deze handleiding

4.3/5 (2 Beoordelingen)

Product specificaties

Merk: Aiphone
Categorie: Intercomsysteem
Model: IXW-HWCBP

Heb je hulp nodig?

Als je hulp nodig hebt met Aiphone IXW-HWCBP stel dan hieronder een vraag en andere gebruikers zullen je antwoorden