Zoom 508 Handleiding


Bekijk gratis de handleiding van Zoom 508 (6 pagina’s), behorend tot de categorie Niet gecategoriseerd. Deze gids werd als nuttig beoordeeld door 7 mensen en kreeg gemiddeld 4.3 sterren uit 4 reviews. Heb je een vraag over Zoom 508 of wil je andere gebruikers van dit product iets vragen? Stel een vraag

Pagina 1/6
Thank you for selecting the ZOOM 508 (hereafter simply called the "508").
Please take the time to read this manual carefully so you can get the most out of
your 508 and ensure optimum performance and reliability.
Retain this manual for future reference.
ZOOM CORPORATION
NOAH Bldg., 2-10-2, Miyanishi-cho, Fuchu-shi, Tokyo 183, Japan
PHONE: 0423-69-7116 FAX: 0423-69-7115
Printed in Japan 508-5000
Compact, dedicated delay unit with up to 4000 ms delay time and eight delay
types (Four types x two variations).
On-board "Zfx-2" DSP (Digital Signal Processor) developed by Zoom, and
an innovative design used solely for its delay effects. Achieves superior
quality delay sound on a par with high-end devices.
You can switch between 24 patches to store diverse settings based on your
preference.
Seamless function that enables smooth patch transitions without cutting the
delay sound when the patch is switched.
Ample functions to support powerful live performances, including a hold
function for continuing the delay sound until the foot switch is pressed, and a
tap function for setting the delay time in the interval between when the foot
switch is pressed.
Integrated auto-chromatic tuner for guitar. You can tune your insturment
easily anywhere, any time. You can also leave the tuning function disabled all
the time.
The optional FP01 expression pedal enables foot control of the mix level for
the delay sound.
Dual power supply design allows the unit to be powered from an alkaline
battery (6LR61) or an AC adapter.
USAGE AND SAFETY PRECAUTIONS
In this manual, symbols are used to highlight warnings and
cautions for you to read so that accidents can be prevented. The
meanings of these symbols are as follows:
Please observe the following safety tips and precautions to ensure
hazard-free use of the 508.
Since power consumption of this unit is fairly high, we
recommend the use of an AC adapter whenever possible.
When powering the unit from a battery, use only an alkaline
type.
AC adapter operation
Be sure to use only an AC adapter which supplies 9 V DC,
300 mA and is equipped with a "center minus" plug (Zoom
AD-0006). The use of an adapter other than the specified type
may damage the unit and pose a safety hazard.
Connect the AC adapter only to an AC outlet that supplies the
rated voltage required by the adapter.
When disconnecting the AC adapter from the AC outlet,
always grasp the adapter itself and do not pull the cable.
If the unit is not to be used for a long time, disconnect the AC
adapter from the outlet.
Battery operation
Use only a 9 V (alkaline) battery (6LR61).
The 508 cannot be used for recharging.
Pay close attention to the labelling of the battery to make sure
you choose the correct type.
If the 508 is not to be used for an extended period of time,
remove the battery from the unit.
If battery leakage has occurred, wipe the battery compartment
and the battery terminals carefully to remove all remnants of
battery fluid.
While using the unit, the battery compartment cover should
be closed.
Avoid using your 508 in environments where it will be
exposed to:
Extreme temperature
High humidity or moisture
Excessive dust or sand
Excessive vibration or shock
The 508 is a precision instrument. Except for the foot
switches, do not push other parts with your feet or subject
them to strong force.
Take care that no foreign objects (coins or pins etc.) or liquids
enter the unit.
Be sure to turn the power to all equipment off before making
connections.
Before moving the unit, turn the power off and disconnect all
cables and the AC adapter.
Never open the case of the 508 or attempt to modify the
product in any way since this can result in damage to the unit.
Usage precautions
For safety considerations, the 508 has been designed to provide
maximum protection against the emission of electromagnetic
radiation from inside the device, and from external
interference.However, equipment that is very susceptible to
interference or that emits powerful electromagnetic waves
should not be placed near the 508, as the possibility of
interference cannot be ruled out entirely.
Whatever the type of digital control device, the 508 included,
electromagnetic damage can cause malfunctioning and corrupt
or destroy data. Since this is an ever-present danger, thorough
care should be taken to minimize the risk of damage.
Use a soft, dry cloth to clean the 508. If necessary, slightly
moisten the cloth. Do not use abrasive cleanser, wax, or
solvents (such as paint thinner or cleaning alcohol), since these
may dull the finish or damage the surface.
Connecting cables and input and output jacks
You should always turn off the power to the 508 and all other
equipment before connecting or disconnecting any cables. Also
make sure to disconnect all cables and the AC adapter before
moving the 508.
Major Features
Safety Precautions
!
Warning
This symbol indicates explanations about extremely
dangerous issues. If users ignore this symbol and handle
the device incorrectly, serious injury or death could
result.
!
Caution
This symbol indicates explanations about dangerous
issues. If users ignore this symbol and handle the
device the wrong way, bodily injury and damage to the
equipment could result.
!
Warning
About power
Caution
Environment
Caution
Handling
Caution
Alterations
Electrical interference
Cleaning
1
2
Operation Manual
The 24 patches can be easily selected by
pressing the patch pedals. The right patch
pedal switches to the next patch and the
left patch pedal switches to the previous
patch.
In the initial condition, the 508 is set up
so that the patch pedals select patches
continuously, but you can also set up the
unit so that patches are switched only
within a certain bank of four patches. [For
details, see section 9 Patch Switching
(Application: Bank Hold ON).]
Banks are selected with the VALUE +/-
keys. Press the VALUE+ key to select the
next bank, and the VALUE- key to select
the previous bank.
For example, to switch from Patch 2,
Bank A to Patch 3, Bank C, the patch
pedal would have to be pressed nine
times. Instead, you can press the
VALUE+ key twice to switch to Bank C,
and then press the patch pedal (UP) just
once to select Patch 3.
The effects of the 508 can
be turned off (bypassed)
temporarily, so that only the
original sound of the
instrument is heard. In this
mode, the auto-chromatic
tuning function via the LED
display is also active.
Bypass mode
Pressing both patch pedals
simultaneously activates the
Bypass mode.
To cancel the Bypass mode,
simply press one of the patch pedals. The unit then reverts to the previously selected patch.
Tuner mode
The 508 is initially set so that the auto-chromatic tuning function for the guitar activates
automatically when the Bypass mode is invoked. In Bypass mode, pick an open string to be
tuned. The closest note will be shown on the display.
When the tuning function is active, the parameter cursor
LEDs serve as tuning meter, designed to enhance tuning
precision during fine adjustments.
Turning tuning function off
If you do not want to activate the tuning function in Bypass
mode, press the STORE and EDIT keys simultaneously for
more than one second in Play mode. The tuning function will be turned off, and this setting will
be stored even when the power is turned off. When you turn the function off, the display will
show "tunEr oFF" (tuning function off).
To turn the tuning function on, press the same keys simultaneously again. The display will show
"tunEr on" (tuning function on).
NOTE: Please note that the tuning function may not operate properly if other effect modules between the
guitar and the 508 are on.
Selecting Patches
Using the Bypass/Tuner Mode
PATCH
DOWN
PATCH
UP
Patch switching
24 patches are available
Bank switching
Banks A, b, C, d, E, F are available
BANK UP
BANK DOWN
BANK F
PATCH 1
PATCH 2
PATCH 3
PATCH 4
BANK E
PATCH 1
PATCH 2
PATCH 3
PATCH 4
BANK d
PATCH 1
PATCH 2
PATCH 3
PATCH 4
BANK C
PATCH 1
PATCH 2
PATCH 3
PATCH 4
BANK b
PATCH 1
PATCH 2
PATCH 3
PATCH 4
BANK A
PATCH 1
PATCH 2
PATCH 3
PATCH 4
Bypass ON/OFF
The bypass function is invoked by pressing the left and right
patch pedals simultaneously.
To cancel the Bypass/Tuner mode, just press one of the
patch pedals.
Calibration
Select reference pitch for auto-chromatic
guitar tuner (calibration).
Press both
pedals together
* The reference pitch (A) can be adjusted in the range
from 435 to 445 Hz. When the BANK key is pressed
in Bypass/Tuner mode, this is shown as "35" to "45"
on the display for a second. Adjust to the suitable
value. At power-on, the setting is 440 Hz (40).
Tuner ON/OFF
Pressing the EDIT key and the STORE key simultaneously for more than one second in
Play mode will allow you to select whether or not to activate the tuning function in Bypass
mode. When you change the setting, the display will show"tunEr oFF" (tuning function off)
or "tunEr on" (tuning function on) according to the setting.
Pitch is too high Correctly tuned Pitch is too low
7
8
Press Release immediately Tuning function (only when the tuning function is ON)
Currently selected
patch is displayed
Do = C
Do# = C#
Re = D
Regular tuning
6th string
1st string
4th string
Mi = E
Fa = F
Fa# = F#
Regular tuning
Regular tuning
3rd string
Regular tuning
5th string
Regular tuning
2nd string
Re# = D#
So = G
So# = G#
La = A
La# = A#
Si = B
Input signal
standby condition
&
w
&
#w
&
w
&
#w
&w
&
w
&
#w
&
w
&
#w
&
w
&
#w
&
w
Bank/patch switching
when Bank Hold is off
(initial setting)


Product specificaties

Merk: Zoom
Categorie: Niet gecategoriseerd
Model: 508

Heb je hulp nodig?

Als je hulp nodig hebt met Zoom 508 stel dan hieronder een vraag en andere gebruikers zullen je antwoorden




Handleiding Niet gecategoriseerd Zoom

Handleiding Niet gecategoriseerd

Nieuwste handleidingen voor Niet gecategoriseerd