Zodiac FloPro VS Handleiding

Zodiac Pomp FloPro VS

Lees hieronder de 📖 handleiding in het Nederlandse voor Zodiac FloPro VS (24 pagina's) in de categorie Pomp. Deze handleiding was nuttig voor 30 personen en werd door 2 gebruikers gemiddeld met 4.5 sterren beoordeeld

Pagina 1/24
H0485400 Rev B
INSTALLATION AND
OPERATION MANUAL
WARNING
FOR YOUR SAFETY: This product must be installed and serviced by a professional service
technician, qualified in pool/spa installation. The procedures in this manual must be followed
exactly. Improper installation and/or operation can create dangerous electrical hazards, which
can cause high voltages to run through the electrical system, possibly causing death, serious
injury or property damage. Improper installation and/or operation will void the warranty.
ATTENTION INSTALLER: This manual contains important information about
the installation, operation and safe use of this product. This information should
be given to the owner/operator of this equipment.
FloPro VS
Variable Speed Pump
H0485400 Rev B2
FloPro VS 1.5 Pump, Installation and Operation Manual
Important Safety Instructions
READ AND FOLLOW ALL INSTRUCTIONS
All electrical work must be performed by a licensed electrician and conform to all national, state, and local codes.
When installing and using this electrical equipment, basic safety precautions should always be followed, including the
following:
WARNING
To reduce the risk of injury, do not permit children to use this product.
WARNING
A check valve can interfere with the proper operation of certain Suction Vacuum Release System
(SVRS) products. To avoid possible entrapment hazard, serious injury, or death, make sure to review
the operation/owners manual of your particular SVRS product before installing the check valve.
WARNING
RISK OF SUCTION ENTRAPMENT HAZARD, WHICH, IF NOT AVOIDED, CAN RESULT IN SERIOUS
INJURY OR DEATH. Do not block pump suction, as this can cause severe injury or death. Do not
use this pump for wading pools, shallow pools, or spas containing bottom drains, unless the pump is
connected to at least two (2) functioning suction outlets. Drain covers must be certiîš¿ed to the latest
published edition of ANSI/ASME A112.19.8 or it’s successor standard ANSI/APSP-16. In Australia
AS1926.3 is also an acceptable standard.
WARNING
To reduce the risk of property damage or injury, do not attempt to change the backwash (multiport, slide,
or full ow) valve position with the pump running.
WARNING
Zodiac® Pumps are powered by a high-voltage electric motor and must be installed by a licensed or
certiîš¿ed electrician or a qualiîš¿ed swimming pool service technician.
WARNING
The pump is for îš¿xed installations only and to be used in conjunction with swimming pool equipment.
(e.g. îš¿lters). The pump is to be installed in accordance with the relevant requirements of the Australian
wiring rules AS/NZS 3000. Also refer to the installation instructions relating to the swimming pool
equipment for which the pump will be an integral part. The pump is to be supplied through a residual
current device (RCD) with a rated residual operating current of 30mA. If the supply cord is damaged it
must be replaced by the manufacturer or its service agent or similarly qualiîš¿ed person in order to avoid
hazard.
WARNING
Incorrectly installed equipment may fail, causing severe injury or property damage.
WARNING
• Do not connect system to an unregulated city water system or other external source of pressurized
water producing pressures greater than 35 PSI.
• Trapped air in the system can cause the lter lid to be blown off, which can result in death, serious
personal injury, or property damage. Be sure all air is out of the system before operating.
H0485400 Rev B3
FloPro VS 1.5 Pump, Installation and Operation Manual
CAUTION
This pump is for use with permanently installed pools and may also be used with hot tubs and spas, if so
marked. Do not use with storable pools. A permanently installed pool is constructed in or on the ground
or in a building, such that it cannot be readily disassembled for storage. A storable pool is constructed
so that it may be readily disassembled for storage and reassembled to its original integrity.
CAUTION
Do not install beneath the skirt of a hot tub. The pump requires adequate ventilation to maintain air
temperature at less than the maximum ambient temperature rating listed on the motor rating plate.
SAVE THESE INSTRUCTIONS
WARNING
Chemical spills and fumes can weaken pool/spa equipment. Corrosion can cause îš¿lters and other
equipment to fail, resulting in severe injury or property damage. Do not store pool chemicals near your
equipment.
CAUTION
Do not start pump dry! Running the pump dry for any length of time will cause severe damage and will
void the warranty.
WARNING
To minimize risk of severe injury or death, the îš¿lter and/or pump should not be subjected to the piping
system pressurization test.
Local codes may require the pool piping system to be subjected to a pressure test. These requirements
are generally not intended to apply to the pool equipment, such as îš¿lters or pumps.
Zodiac® pool equipment is pressure tested at the factory.
If, however, the WARNING cannot be followed and pressure testing of the piping system must include
the îš¿lter and/or pump, BE SURE TO COMPLY WITH THE FOLLOWING SAFETY INSTRUCTIONS:
• Check all clamps, bolts, lids, lock rings, and system accessories to ensure they are properly installed
and secured before testing.
• RELEASE ALL AIR in the system before testing.
• Water pressure for test must NOT EXCEED 35 PSI.
• Water temperature for test must NOT EXCEED 100 F (38° °C).
• Limit test to 24 hours. After test, visually check system to be sure it is ready for operation.
Notice: These parameters apply to equipment only. For non- equipment, consult the Zodiac Zodiac
equipment manufacturer.


Product specificaties

Merk: Zodiac
Categorie: Pomp
Model: FloPro VS

Heb je hulp nodig?

Als je hulp nodig hebt met Zodiac FloPro VS stel dan hieronder een vraag en andere gebruikers zullen je antwoorden




Handleiding Pomp Zodiac

Handleiding Pomp

Nieuwste handleidingen voor Pomp