Wijas Perfect 9000 Handleiding

Wijas Boilers Perfect 9000

Bekijk gratis de handleiding van Wijas Perfect 9000 (12 pagina’s), behorend tot de categorie Boilers. Deze gids werd als nuttig beoordeeld door 57 mensen en kreeg gemiddeld 4.5 sterren uit 29 reviews. Heb je een vraag over Wijas Perfect 9000 of wil je andere gebruikers van dit product iets vragen? Stel een vraag

Pagina 1/12
Pressurized water flow heater
PERFECT 7000, 8000, 9000
ASSEMBLY AND OPERATION
MANUAL
2
Table 1
Advantages of pressurized water ow heaters “PERFECT”:
Signicantelectricpowersavingcomparingtoaboiler
Instantandpermanentwarmwaterdelivery
Electronicpowerswitchprolongssignicantlyheater’slife
Possibilitytousetheheaterwithverylowwaterpressure(ca0,06MPa)
Thankstoinstalledelectroniccontrolsystemthemostunreliablemechanicalpartssuch
asmembrane,traditionalelectricalcontactsareeliminated.Signicantprolongationof
theappliancelifeandimprovedreliabilityisreachedinresult.
1. Application
PressurizedwaterowheaterPERFECTisdesignedforinstantdeliveryofwarmwater
tosanitaryequipmentsuchaswashbasins,sinks.Inordertoeconomicalusetheheater
shouldbeinstalledascloseaspossibletotheservedequipment.
Thisapplianceisfullydesignedtobeusedinmoistureenvironment.Howeversplashing
withwaterisprohibited.Maximumdeliveredwatertemperatureshouldnotexceed30ºC.
Oneshouldrememberthatheateroutputdependson:
itelectricpower;
waterstreamowingthroughtheappliance.Thebiggerow,thelowerwatertempera-
tureonexit(table1);
voltagedropinelectricalsystem.Forinstance:voltagedropby10%resultsinlowering
heatoutputby19%(table2).Voltagedropbelow340Vcausesblockageofappliance
powerswitchbyelectronicsystem;
deliveredwatertemperature.
Suppliedwatertemperature15ºC
Waterow [l/min] 2,5 3 3,5 4 4,5
Perfect 7000 [OC] 55 48 43 40 37
Perfect 8000 [OC] 60 53 47 43 40
Perfect 9000 [OC] 57 51 46 43
3
Heaterpowerdependingonvoltageinelectricsystem
Table 2
CAUTION!
Power must be switched off before starting any work over installation,
opening cover or incline the installed heater!
The heater can only work in position showed on drawing No 1 below.
Starting the device in position other than proper one will result in dam-
aging a heating element and deprivation of guarantee.
Voltage [V] 400 390 380 370 360
Perfect 7000 [W] 7000 6650 6300 5989 5670
Perfect 8000 [W] 8000 7600 7200 6800 6480
Perfect 9000 [W] 9000 8550 8100 7650 7290
Fig.1
GOOD WRONG WRONG WRONG
2. Safety regulations
Heatercanonlybeinstalledbyauthorizedperson
Heatermust permanentlybe connectedto electricalsystem equippedwith earthing
connectoranddifferentialswitch
Heatercanonlyworkinpositionpresentedondrawing1
Donotexchangeearthingwirewithlivewire
Heatercanonlyworkusingperfectlyworkingsafetydevices
Heatermustnotbeinstalledinroomswheretemperaturedropsbelow0ºC
Applianceshouldnotbeinstalledinaggressiveordangerofexplosionenvironment


Product specificaties

Merk: Wijas
Categorie: Boilers
Model: Perfect 9000

Heb je hulp nodig?

Als je hulp nodig hebt met Wijas Perfect 9000 stel dan hieronder een vraag en andere gebruikers zullen je antwoorden