Westinghouse iGen4500DF Handleiding

Westinghouse Generator iGen4500DF

Lees hieronder de 📖 handleiding in het Nederlandse voor Westinghouse iGen4500DF (94 pagina's) in de categorie Generator. Deze handleiding was nuttig voor 24 personen en werd door 2 gebruikers gemiddeld met 4.5 sterren beoordeeld

Pagina 1/94
USER MANUAL
iGen4500DF
Digital Inverter Generator
Gasoline: 3700 Running Watts | 4500 Peak Watts
Propane: 3330 Running Watts | 4050 Peak Watts
DO NOT RETURN THIS PRODUCT TO THE STORE
If you have questions or need assistance, please call customer
service at 855-944-3571.
2 | Westinghouse Outdoor Power Equipment, LLC
INTRODUCTION
WARNING: Operating, servicing, and maintaining
this equipment can expose you to chemicals including
engine exhaust, carbon monoxide, phthalates, and lead,
which are known to the State of California to cause
cancer and birth defects or other reproductive harm. To
minimize exposure, avoid breathing exhaust, and wear
gloves or wash your hands frequently when servicing
this equipment. For more information go to www.
P65warnings.ca.gov.
DISCLAIMERS
All information, illustrations, and speciî·”cations in
this manual were in effect at the time of publishing.
The illustrations used in this manual are intended as
representative reference views only. We reserve the right
to make any speciî·”cation or design change without notice.
ALL RIGHTS RESERVED
All rights reserved. No reproduction allowed in any form
without written permission from Westinghouse Outdoor
Power Equipment, LLC.
Read this manual before using or performing
maintenance on this product. Failure to follow
the instructions and safety precautions in this
manual can result in serious injury or death.
SAVE THESE INSTRUCTIONS
INTRODUCTION
TABLE OF CONTENTS
INTRODUCTION
DISCLAIMERS 2 .........................................................................
ALL RIGHTS RESERVED 2 ........................................................
SPECIFICATIONS
SPECIFICATIONS....................................................................3
SAFETY
SAFETY DEFINITIONS............................................................4
SAFETY SYMBOLS 4 .................................................................
SAFETY INSTRUCTIONS 5 .......................................................
SAFETY LABELS AND DECALS 8 .............................................
COMPONENTS
GENERATOR COMPONENTS 9 ................................................
DIGITAL DATA CENTER 9 ..........................................................
CONTROL PANEL COMPONENTS 10 .......................................
ASSEMBLY
INITIAL OIL FILL ....................................................................11
FUEL ......................................................................................12
CONNECT AN LPG/PROPANE TANK ...................................12
CONNECT THE BATTERY ....................................................13
OPERATION
GENERATOR LOCATION 14 ......................................................
GROUNDING 14 .........................................................................
REMOTE START ...................................................................15
FUEL SELECTOR SWITCH 15 ..................................................
BREAK-IN PERIOD 15 ...............................................................
BEFORE STARTING THE GENERATOR 15 ..............................
STARTING THE ENGINE: GASOLINE 16 ..................................
STARTING THE ENGINE: LPG 16 .............................................
SWITCHING FUEL SOURCES 16 ..............................................
STOPPING THE ENGINE ......................................................16
FREQUENCY OF USE 16 ..........................................................
ECO MODE 17 ............................................................................
AC CIRCUIT BREAKERS 17 ......................................................
OVERLOAD RESET 17 ..............................................................
GENERATOR CAPACITY 17 ......................................................
POWER MANAGEMENT 18 .......................................................
EXTENSION CORDS 19 ............................................................
PARALLEL OPERATION........................................................19
TRANSPORTING 20 ...................................................................
MAINTENANCE
MAINTENANCE SCHEDULE 21 ................................................
MAINTENANCE REPLACEMENT PARTS 21 ............................
AIR FILTER MAINTENANCE 21 .................................................
ENGINE OIL LEVEL CHECK 22 .................................................
ENGINE OIL CHANGE 23 ..........................................................
SPARK PLUG MAINTENANCE 23 .............................................
SPARK ARRESTOR SERVICE ..............................................24
BATTERY MAINTENANCE 24 ....................................................
BATTERY REPLACEMENT 24 ...................................................
STORAGE 25 ..............................................................................
VALVE CLEARANCE 26 .............................................................
MANUALLY SET THE CHOKE 26 ..............................................
TROUBLESHOOTING
TROUBLESHOOTING 27 ...........................................................
EXPLODED VIEWS AND PARTS LISTS
ENGINE EXPLODED VIEW 29 ...................................................
ENGINE PART NUMBERS 30 ....................................................
GENERATOR EXPLODED VIEW 32 ..........................................
GENERATOR PART NUMBERS 33 ............................................
SCHEMATICS
SCHEMATICS 35 ........................................................................
ESPAÑOL .............................................................................36
FRANÇAIS ...........................................................................65
Westinghouse Outdoor Power Equipment, LLC | 3
SPECIFICATIONS
SPECIFICATIONS
SPECIFICATIONS
Model: iGen4500DF
Running Watts: 3700 Gas / 3330 LPG
Peak Watts: 4500 Gas / 4050 LPG
Rated Voltage: 120V
Rated frequency: 60 Hz
Phase: Single phase
Total Harmonic
Distortion: ≤ 3%
Engine Displacement: 224 cc
Starting Type: Recoil, Electric Start,
Remote
Fuel Capacity: 3.4 Gal (12.8 L)
Fuel Type: *87–93 octane
Oil Capacity: 0.63 US qt (0.60 L)
Oil Type: 10W30
Spark Plug: F7RTC
Spark Plug Gap: 0.024 – 0.032 in.
(0.60 – 0.80 mm)
Valve Intake
Clearance:
0.0031 – 0.0047 in
(0.08 – 0.12 mm)
Valve Exhaust
Clearance:
0.0051 – 0.0067 in
(0.13 – 0.17 mm)
AC Grounding System: Floating neutral
Voltage Regulator: Digital
Alternator Type: Permanent magnet
Maximum Ambient
Temperature: 104°F (40°C)
Certiî·”cations:
• EPA
• CARB
• CSA Group
*Ethanol content of 10% or less. DO NOT use E15 or E85.
NOTICE
This product is designed and rated for continuous
operation at ambient temperatures up to 104°F (40°C).
If needed, this product can be operated at temperatures
ranging from 5°F (15°C)–122°F (50°C) for short periods.
If the product is exposed to temperatures outside of this
range during storage, it should be brought back within
this range before operation. This product must always
be operated outdoors in a well-ventilated area and away
from doors, windows, and other vents.
Maximum wattage and current are subject to and
limited by such factors as fuel BTU content, ambient
temperature, altitude, engine conditions, etc. Maximum
power decreases about 3.5% for each 1,000 feet above
sea level, and will also decrease about 1% for each 10°F
(6°C) above 60°F (16°C) ambient temperature.
PRODUCT REGISTRATION
For trouble-free warranty coverage, it is important to
register your Westinghouse generator.
You can register by:
• Completing and mailing the product registration card
included in the carton.
• Registering your product online at:
https://westinghouseoutdoorpower.com/pages/
warranty-registration
• Scanning the following QR code with your smartphone
camera. You will be directed to the mobile registration
link.
• Sending the following product information to:
Westinghouse Outdoor Power
Warranty registration
777 Manor Park Drive
Columbus, OH 43228
For Your Records
Date of Purchase:
Model Number:
Serial Number:
Place of Purchase:
IMPORTANT: Keep your purchase receipt for trouble-free
warranty coverage.


Product specificaties

Merk: Westinghouse
Categorie: Generator
Model: iGen4500DF

Heb je hulp nodig?

Als je hulp nodig hebt met Westinghouse iGen4500DF stel dan hieronder een vraag en andere gebruikers zullen je antwoorden




Handleiding Generator Westinghouse

Handleiding Generator

Nieuwste handleidingen voor Generator