Bekijk gratis de handleiding van WAC Lighting EN-24100-RB2-T (1 pagina’s), behorend tot de categorie Niet gecategoriseerd. Deze gids werd als nuttig beoordeeld door 2 mensen en kreeg gemiddeld 4.5 sterren uit 3 reviews. Heb je een vraag over WAC Lighting EN-24100-RB2-T of wil je andere gebruikers van dit product iets vragen? Stel een vraag
Pagina 1/1

1
INSTRUCTIONS Class II Power Unit
Model EN-2460-RB2-T
CAUTION – TO REDUCE RISK OF FIRE AND ELECTRICAL SHOCK
When installing or using the lighting system, basic safety precautions should always be followed including the following:
Read all instructions.
Do not conceal or extend exposed conductors through a building wall.
To reduce the risk of fire and burns, do not install this lighting system where the exposed bare conductors can
be shorted or contact any conductive materials.
To reduce the risk of overheating and potential fire risk, make sure all connections are tight.
Do not install any fixture assembly closer than 6 in. from any curtain, or similar combustible material.
Turn off electrical power before modifying the light system in any way.
MAX LOAD 60W
MIN LOAD 1W
INPUT VOLTAGE V 120ac
INPUT CURRENT 6A 0.max
OUTPUT VOLTAGE 2Vac 4.0
AMBIENT TEMP
--4 20ºC TO 50ºC (°F TO 122°F)
FEATURES:
•Electronic short circuit protection with auto-reset.
•Overload protection with auto-reset.
•Automatic thermal regulation.
•Soft start delay to preserve bulb life, for use with tungsten filament lamps.
INSTALLATION
•Loosen two cover screws and remove the cover.
•The power Unitshould be installed on the surface of any indoor construction . with two screws
•Power unit must be installed away from heat sources and accessible for service.
•Note: Enclosed transformer is UL listed. Power unit box has a separate line volt, and low volt wiring compartments.
Trade size knock out are provided on both compartments. Connect building wires to like color power unit wires with
wire nuts. Building ground wire may be green or uninsulated, and attaches to green wire from power unit- box.
•Use a minimum of #AWG for the output wire.20
•Connect out put wires from power unitto fixture wires with wire nuts. Where multiple fixtures are involved several
fixtures wires can be joined by use of the same wire nut. Wires to fixtures may be chain wired or “ home run” wired
back to the power unit. High frequency output is only readable with a true RMS meter, with sufficient range
capability.
•After connecting all the s, secure the cover by tightening the two screws.wire
Retain these instructions for future service and adjustments
615 South Street, Garden City, NY 11530
Tel: (516) 5155000 Fax (51-65-) 515050
www.waclighting.com
Product specificaties
| Merk: | WAC Lighting |
| Categorie: | Niet gecategoriseerd |
| Model: | EN-24100-RB2-T |
Heb je hulp nodig?
Als je hulp nodig hebt met WAC Lighting EN-24100-RB2-T stel dan hieronder een vraag en andere gebruikers zullen je antwoorden
Handleiding Niet gecategoriseerd WAC Lighting
23 Februari 2026
23 Februari 2026
13 Februari 2026
12 Februari 2026
12 Februari 2026
12 Februari 2026
12 Februari 2026
12 Februari 2026
12 Februari 2026
11 Februari 2026
Handleiding Niet gecategoriseerd
Nieuwste handleidingen voor Niet gecategoriseerd
23 Februari 2026
23 Februari 2026
23 Februari 2026
23 Februari 2026
23 Februari 2026
23 Februari 2026
23 Februari 2026
23 Februari 2026
23 Februari 2026
23 Februari 2026