Victron Energy Argofet Battery Isolator Handleiding
Pagina's 1 Niet gecategoriseerd
Bekijk de handleiding van Victron Energy Argofet Battery Isolator gratis online of download de PDF. Deze handleiding is 2 keer bekeken. Vraag over dit model? Stel een vraag

www.victronenergy.com
Victron Energy B.V. | De Paal 35 | 1351 JG Almere | The Netherlands
General phone: +31 (0)36 535 97 00 | E-mail: sales@victronenergy.com
www.victron
www.victron
www.victron
www.victronwww.victronenergy
energy
energy
energyenergy.com
.com
.com
.com.com
ArgoArgoArgoArgoArgofet Battery Isolatorfet -2 100fet -3 100fet 200-2 fet -3 200
Maximum charge current (A) 100100200200
Maximum alternator current (A)
100
100
200
200
Number of batteries
2
3
2
3
Connection M8 boltsM8 boltsM8 boltsM8 bolts
Weight kg (lbs) 1,4 (3.1)1,4 (3.1)1,4 (3.1)1,4 (3.1)
Dimensions:
h x w x d in mm
(h x w x d in inches)
65 x 120 x 200
(2.6 x 4.7 x 7.9)
65 x 120 x 200
(2.6 x 4.7 x 7.9)
65 x 120 x 200
(2.6 x 4.7 x 7.9)
65 x 120 x 200
(2.6 x 4.7 x 7.9)
Similarly to solators allow simultaneous charging of two or more batteries Argodiode Battery Isolators, Argofet
I
from one alternator (or a single output battery charger), without connecting the batteries together. Discharging
the accessory battery for example will not result in also discharging the starter battery.
In contrast with Diode Battery Isolators, FET
Isolators have virtually no voltage loss. Voltage drop is less than
0,02 Volt at low current and averages 0,1Volt at higher currents.
When using Battery Isolators, there is no need to also increase the output voltage of the alternator. Argofet
However, care should betaken to keep cable lengths short and of sufficient cross section.
Example:
When a current of 100 A flows through a cable of 50 mm² cross section (AWG 0) and 10 m length (30ft), the
voltage drop over the cable will be 0,26 Volt. Similarly a current of 50 A through a cable of 10 mm² cross section
(AWG 7) and 5 m length (15 ft) will result in a voltage drop of 0,35 Volt!
Alter
Alter
Alter
AlterAlternator
nator
nator
natornatore
e
e
e energi
nergi
nergi
nerginergize
ze
ze
zezeinp
inp
inp
inp input
ut
ut
utut
Some alternators need DC voltage on the B+ output to start charging. Obviously, DC will be present when the
alternator is directly connected to a battery. Inserting a Argodiode or Argofet
splitter will however prevent any
return voltage/current from the batteries to the B+, and the alternator will not start.
The new Argofet Isolators have a special current limited energize input that will power the B+ when the engine
run/stop switch is closed.
ARGOFET Battery Isolators
With alternator energize input
Argo
Argo
Argo
ArgoArgofet
fet
fet
fetfet
-
-
-
--3
3
3
3 3
100
100
100
100100
3bat
3bat
3bat
3bat 3bat 10
10
10
10100
0
0
00A
A
A
AA
Argo
Argo
Argo
ArgoArgofet
fet
fet
fetfet
-
-
-
--3
3
3
3 3
100
100
100
100100
3
3
3
33ba
ba
ba
babat
t
t
t t 100A
100A
100A
100A100A
Product specificaties
| Merk: | Victron Energy |
| Categorie: | Niet gecategoriseerd |
| Model: | Argofet Battery Isolator |
Heb je hulp nodig?
Als je hulp nodig hebt met Victron Energy Argofet Battery Isolator stel dan hieronder een vraag en andere gebruikers zullen je antwoorden