Bekijk gratis de handleiding van Vemer Eos DN (2 pagina’s), behorend tot de categorie ivópalack. Deze gids werd als nuttig beoordeeld door 27 mensen en kreeg gemiddeld 4.4 sterren uit 5 reviews. Heb je een vraag over Vemer Eos DN of wil je andere gebruikers van dit product iets vragen? Stel een vraag
Pagina 1/2

Dimensions
Connections
Description
V3IS00409-011
Mod.Eos
Eos DN
Eos SW
Vemer S.p.A.
I - 32032 Feltre (BL) • Via Camp Lonc, 16
Tel +39 0439 80638 • Fax +39 0439 80619
e-mail: info@vemer.it - web site: www.vemer.it
is an electronic thermostat, semi-fl ush mount for box 503, featuring temperature
control by knob and load-on indication light. The package includes the relevant mounting
support, also for wall installation.
Besides the EOS base model, the following versions are available:
- EOS DN, featuring a selector switch by which it is possible to turn the temperature setting
down by 3°C
- EOS SW, featuring a selector switch by which it is possible to control both heating and
A/C systems
SAFETY INSTRUCTIONS
The EOS thermostat performs 1B-type actions and is aimed for household or similar premises,
under a normal pollution degree.
During product installation and operation, it is necessary to observe the following
instructions:
1) The instrument must be installed by a qualifi ed person
2) Disconnect power supply while installing the unit
3) Do not power or connect the product if any part of it is damaged
4) Connect the product considering the diagrams described in the following manual and
on the instrument
CodeModel DescriptionFunction
VE084000 EosThermostat with warning lampHeating
VE085700 Eos DNThermostat with warning lamp
and day/night/OFF switch
Heating and night offset of 3°C
VE086500 Eos SWThermostat with warning lamp
winter/OFF/summer switch
Heating and A/C
VE151700Eos grayThermostat with warning lampHeating
VE167300Eos gray
DN
Thermostat with warning lamp
and day/night/OFF switch
Heating and night offset of 3°C
VE168100Eos gray
SW
Thermostat with warning lamp
winter/OFF/summer switch
Heating and A/C
TECHNICAL SPECIFICATIONS
• Power supply: 230Vac (± 10%), 50/60Hz
• Device consumption: 3VA (0,5W)
• Output: relay with exchange contact
8A / 250Vac (resistive load)
2000VA (resistive load)
• Output status signalling: red light on when load is on
• Termination:
– terminal-strip power supply: 2 poles, maximum section of cables 1,5 mm²
– relay output terminal strip: 3 poles, maximum section of cables 1,5 mm²
• Installation:
– on wall dimensions 113x73x32,4 mm
– semi-fl ush mount on 503 box: dimensions 113x73x15,5 mm
• Temperature control range:
– SUMMER/WINTER modes: +5°C ÷ + 30°C
– NIGHT mode: +2°C ÷ + 27°C
• Night offset (for EOS DN only): fi xed - 3°C from temperature setting
• Cut-in differential: fi xed 1°C for ON/OFF-type temperature control
• Accuracy: ±0,5C°
• Operating conditions:
– temperature 0°C ÷ + 40°C
– relative humidity 20% ÷ 90%, non-condensing
• Storage temperature: - 10°C ÷ + 60°C
• Enclosure: white thermoplastic ABS
• Protection rating: IP30
• Insulation class: II (double between accessible parts and terminals)
User Manual
ELECTRONIC THERMOSTAT
Read all instructions carefully
DEVICE DESCRIPTION
room temperature control knob from +5°C to 30°C
red “ON” warning light on load on (between COM and NO)
off load off
operating mode selector (not featured on the EOS base version):
EOS DN
“Sun” setpoint: heating (between COM and NO)
“night” setpoint: heating, but with temperature offset of 3°C below the knob setting
(e.g. if the knob setting is 22°C, control temperature will be 19°C)
position “OFF”: the thermostat is off
EOS SW
“Winter” setpoint: heating (between COM and NO)
“Summer” setpoint: A/C (tra COM ed NO)
position “OFF”: the thermostat is off
INSTALLATION AND MOUNTING
It is advisable to choose for the thermostat a position in a zone in which the temperature
is the room average value.
Do not install it too near doors, windows, sources of heat, direct sunlight or in places in
which airing is too much or too poor.
Installing the thermostat about 150cm from the fl oor is recommended.
• SEMI-FLUSH MOUNTING (BOX 503)
Connect the power and relay terminals (refer to the wiring diagrams).
Fasten the thermostat to the 503 box using the two screws attached.
Place the silk-screen printed front shell by pressing on the four corners simultaneously.
(The wall-mounting base is not used)
• WALL MOUNTING
Fasten the base to the wall.
Connect power and relay terminals (refer to the wiring diagrams) and then fi t the
thermostat in.
Place the silk-screen printed front shell by pressing on the four corners simultaneously.
In order to access to the wiring when the device is in its service position, cut off the power
supply, insert a fl at-head screwdriver into the slots on the sides as shown on fi gure, lift the
front shell and remove the thermostat.
If the thermostat is installed on the wall, place a fl at-head screwdriver into the upper and
lower slots to remove it (as shown in the fi gure).
REFERENCE STANDARDS
Conformity with EU directives:
2006/95/EC (Low Voltage)
89/336/EEC modifi ed by 92/31/EEC and 93/68/EEC (EMC)
is declared with reference to the following harmonised standards:
Safety: EN 60730-2-9
Electromagnetic compatibility: EN 61000-6-1, EN 61000-6-3
113
73
15.5
11.5
32.4
28.5
Heating and A/C systems
Max 8A 250Vac (resistive load)
POWER SUPPLY 230V~
L
N
COM
NO
NC
5
10
15 20
25
30
Eos
2
3
1
Wall mounting
60
Semi-fl ush mounting (box 503)
Product specificaties
| Merk: | Vemer |
| Categorie: | ivópalack |
| Model: | Eos DN |
Heb je hulp nodig?
Als je hulp nodig hebt met Vemer Eos DN stel dan hieronder een vraag en andere gebruikers zullen je antwoorden
Handleiding ivópalack Vemer
25 Augustus 2025
29 Januari 2025
6 November 2024
7 Februari 2024
6 Februari 2024
6 Februari 2024
4 Januari 2024
20 Mei 2023
19 Mei 2023
14 Mei 2023
Handleiding ivópalack
Nieuwste handleidingen voor ivópalack
16 Januari 2026
23 December 2025
22 December 2025
22 December 2025
22 December 2025
21 December 2025
20 December 2025
20 December 2025
19 December 2025
19 December 2025