Tripp Lite SRCOOL7KRM Handleiding

Tripp Lite Airco SRCOOL7KRM

Lees hieronder de 📖 handleiding in het Nederlandse voor Tripp Lite SRCOOL7KRM (32 pagina's) in de categorie Airco. Deze handleiding was nuttig voor 22 personen en werd door 2 gebruikers gemiddeld met 4.5 sterren beoordeeld

Pagina 1/32
1
Rackmount Air Conditioning Unit
SRCOOL7KRM (120V, 60 Hz)
Owner’s Manual
Introduction 2
Important Safety Instructions 2
Features 3
Accessories 4
Installation 4
Optional Accessories 7
Operation 7
Maintenance 8
Troubleshooting 9
Storage & Service 10
Warranty & Product Registration 10
EspaĂąol 11
Français 22
1111 W. 35th Street, Chicago, IL 60609 USA • www.tripplite.com/support
Copyright Š 2014 Tripp Lite.
PROTECT YOUR INVESTMENT!
Register your product for quicker service and ultimate peace of mind.
You could also win an ISOBAR6ULTRA surge protector—a $50 value!
www.tripplite.com/warranty
Vent installed
facing upward
Vent installed
facing downward
2
Introduction
The self-contained Rackmount Air Conditioning Unit provides 7,000 BTU (up to 2 kWh) of supplemental cooling capacity. Designed for IT
environments, it’s ideal for cooling overheated rack enclosures and network closets without access to facility air conditioning. It also filters and
dehumidifies air to improve operating conditions and equipment reliability. Condensate is re-evaporated for drip-free operation, so you won’t
waste time emptying water collection tanks. The self-contained design does not require any plumbing or special circuits, so setup is quick and
easy. Eco-friendly R410A refrigerant meets environmental standards.
Recommended Applications:
Important Safety Instructions
SAVE THESE INSTRUCTIONS
This manual contains instructions and warnings that should be followed during the installation, operation
and storage of this product. Failure to heed these warnings may affect your warranty.
Warnings
• The individual user should determine prior to use whether this device is suitable, adequate or safe for the use intended. Since individual
applications are subject to great variation, the manufacturer makes no representation or warranty as to the suitability or tness of this device
for any specic application.
• Install the unit indoors, away from extreme temperatures or humidity, direct sunlight, dust and conductive contaminants.
• Connect the unit directly to a grounded AC power outlet. Failure to do so may cause an electric shock or fire.
• The power source supplying the unit must be rated in accordance with the unit’s nameplate.
• Do not modify the plug nor use an adapter that would eliminate the ground connection.
• Do not use an extension cord to connect the unit to an AC outlet. Use only the power cord that came with the unit.
• Comply with all applicable wiring and safety regulations, such as National Electrical Code (NEC) in the United States.
• Do not plug additional equipment into the outlet where the unit is plugged in. Overloading the outlet may cause an electric shock or fire.
• Do not attempt to turn the unit on or off by connecting or disconnecting the AC plug. A serious electric shock may occur. Use the ON/OFF
button to turn the unit on or off.
• Turn the unit off and unplug it from the AC outlet before performing maintenance.
• Before connecting the unit to a dedicated drainage system, turn it off and unplug it. There is a risk of electric shock while the unit is plugged in.
• Maintenance should be performed by trained personnel only.
• Do not use thinners, alcohol, detergents or abrasive brushes to clean the unit’s cabinet. These items may damage the cabinet.
• Do not pour water over the unit. This may cause an electric shock and damage the unit.
• Do not operate the unit without the air filter. This may cause dust accumulation that may damage the unit.
• Do not attempt to operate the unit in a room with inadequate air circulation.
• Use of this equipment in life support applications where failure of this equipment can reasonably be expected to cause the failure of the life
support equipment or to signicantly affect its safety or effectiveness is not recommended. Do not use this equipment in the presence of a
flammable anesthetic mixture with air, oxygen or nitrous oxide.
Cooling an overheated rack enclosure.
A
IH
GF
C
E
A
B
B
B
D
C
H
I
J
D
E
G
F
3
Features
Front View
A Directional Vent
B Cool Air Output
C SRCOOLNET2 Slot
D Control Panel
E Air Filter
F Front Panel
G Blocking Plate
Rear View
H AC Power Cord
I Warm Air Exhaust
J Drainage Outlet
Control Panel
A Numeric Display
B Operating Mode LEDs
C Temperature Control Buttons
D Fan Speed Mode LEDs
E “FAN SPEED” Button
F “QUIET” Button
G “TIMER” Button
H “FUNCTION” Button
I “POWER” Button


Product specificaties

Merk: Tripp Lite
Categorie: Airco
Model: SRCOOL7KRM
Kleur van het product: Zwart
Gewicht: 27940 g
Breedte: 440.7 mm
Diepte: 572 mm
Hoogte: 353.1 mm
Gewicht verpakking: 36290 g
Breedte verpakking: 576.6 mm
Diepte verpakking: 698.5 mm
Hoogte verpakking: 579.1 mm
LED-indicatoren: Ja
Land van herkomst: China
Compatibiliteit: Tripp Lite SRCOOLNET2, SRCOOL7KDUCT
(Buitenste) hoofdverpakking hoogte: 579.1 mm
(Buitenste) hoofdverpakking breedte: 576.6 mm
(Buitenste) hoofdverpakking brutogewicht: 36290 g
(Buitenste) hoofdverpakking lengte: 698.5 mm
Hoeveelheid per (buitenste) hoofdverpakking: 1 stuk(s)
Code geharmoniseerd systeem (HS): 8415.82.0105

Heb je hulp nodig?

Als je hulp nodig hebt met Tripp Lite SRCOOL7KRM stel dan hieronder een vraag en andere gebruikers zullen je antwoorden




Handleiding Airco Tripp Lite

Handleiding Airco

Nieuwste handleidingen voor Airco