Tripp Lite PowerAlert 12 Handleiding

Tripp Lite UPS PowerAlert 12

Lees hieronder de 📖 handleiding in het Nederlandse voor Tripp Lite PowerAlert 12 (21 pagina's) in de categorie UPS. Deze handleiding was nuttig voor 26 personen en werd door 2 gebruikers gemiddeld met 4.5 sterren beoordeeld

Pagina 1/21
1
User’s Guide
PowerAlert® Network Shutdown Agent Software
Note: PowerAlert is not required to operate your UPS system. For the latest PowerAlert updates, go to www.tripplite.com/products/power-alert
1111 W. 35th Street, Chicago, IL 60609 USA • www.tripplite.com/support
Copyright © 2018 Tripp Lite. All Rights Reserved. All trademarks are the property of their respective owners.
1. Introduction 2 ...............................................................................................
2. Windows Implementation 3 ..........................................................................
2.1 Pre-Installation ......................................................................................3
2.2 Installation ............................................................................................ 3
2.3 Configuration .........................................................................................3
2.3.1 Event Settings 4 ............................................................................
2.3.2 Shutdown....................................................................................4
2.3.3 Command Execution 4 ...................................................................
2.3.4 Operating Mode 5 ..........................................................................
2.3.5 Security 5 ......................................................................................
2.4 System Tray Icon 6 ...................................................................................
2.5 Performing a Silent Installation of PowerAlert 6 ........................................
2.6 Using the paconfig.ini File 6 ......................................................................
3. Linux Implementation 7 ................................................................................
3.1 Pre-Installation ......................................................................................7
3.2 Installation 7 ............................................................................................
3.3 Configuration 7 .........................................................................................
3.3.1 Configuring PANSA Using the Configuration File 7 ...........................
3.4 Uninstalling PANSA 9 ................................................................................
3.5 Using the poweralert.conf File 9 ...............................................................
4. VMware Implementation (ESXi Server Environments) 10 .............................
4.1 PANSA for VMware vSphere Management Assistant (vMA) 10 ....................
4.1.1 Installation 11 ...............................................................................
4.1.2 Configuration 12 .............................................................................
4.1.3 Modifying and Configuring Scripts 13 ..............................................
4.2 PANSA for Non-vMA Operating Systems 13 ...............................................
4.3 PowerAlert Local..................................................................................14
5. Troubleshooting 14 .......................................................................................
6. Technical Support 16 ....................................................................................
APPENDIX A – Sample Scripts 16 .......................................................................
APPENDIX B – poweralert.conf File 20 ...............................................................
2
1. Introduction
PowerAlert Network Shutdown Agent (PANSA) monitors one or two network-attached Tripp Lite UPS systems for specific power events, takes
the appropriate action to gracefully shutdown operating systems or execute scripts, and protects systems from data loss or corruption.
Example actions include shutting down the computer receiving UPS backup power when the UPS enters a low battery condition or, in a
VMware application, signaling an ESXi Host to shut down. If the ESXi Host is a member of a high availability cluster, the desired response to
the On Battery event could be to shut down the virtual machines running on the host before shutting down the host itself. This User’s Guide
will cover the basic scenarios.
Feature Comments
Unattended computer operating system shutdown Must monitor WEBCARDLX, SNMPWEBCARD or
PowerAlert Local for shutdown signal
Autodiscovery of SNMP-enabled devices Discovers devices accessible on the network via
WEBCARDLX, SNMPWEBCARD and PowerAlert Local
(software version 12.04.0040 and above)
Figure 1.1: PowerAlert Network Shutdown Agent Key Features
This document is divided into three sections, each covering implementation with a different operating system / environment. Please refer to
the section that applies to your environment:
Windows ImplementationSection 2.
Linux ImplementationSection 3.
VMware ImplementationSection 4.
3
2. Windows Implementation
2.1 Pre-Installation
Note: PANSA requires pre-installation configuration of firewall software settings and/or WEBCARDLX/SNMPWEBCARD settings.
Open UDP ports 161, 162, 3664 and 3665 on your computer’s firewall software and disable the Windows SNMP trap service.
The host computer for the device PANSA will be monitoring must also have UDP ports 161, 162, 3664 and 3665 open on its firewall
software.
If PANSA will be configured to monitor a WEBCARDLX or SNMPWEBCARD, enable the card’s SNMP access and define a read/write
community string (the default community string forrmware version 12.04.0048 and above is ).tripplite
Warning: Do not install more than one edition of a PowerAlert product on a single computer.
If you have a previous version of PANSA installed, Tripp Lite recommends you manually uninstall it prior to installing the new version.
2.2 Installation
Go to www.tripplite.com/products/power-alert-network-shutdown-agent to download the latest PANSA installer package for Windows.
Once downloaded, double-click the PowerAlert installer and follow the on-screen prompts. The installer will attempt to uninstall previous
versions of PANSA (if this action was not performed during pre-installation).
If you experience issues installing PANSA, uninstall any current versions then right-click on the install file and select “Run as Administrator”.
Current Windows platforms are supported.
2.3 Configuration
After installation, the option to launch the PANSA Console (Figure 2.3.1) becomes available. The Console contains all the controls required
to operate PANSA.
The “Monitored UPS” fields will be blank when PANSA starts up for the first time. Click the “Discover Agents” button to open the discovery
settings window (Figure 2.3.2). Enter an IP address and community name ( is the default). You must click the “Add to list” button tripplite
after each entry and can add multiple entries, if desired. Use the asterisk character (*) as a wildcard in the IP addresseld. For example,
192.168.1.* will cover 192.168.1.1 through 192.168.1.255. If you know the specic IP address of the device you plan to monitor, enter
that address. If you are unsure what information to enter in the discovery settings window, contact your network administrator for assistance.
Figure 2.3.1
Figure 2.3.2
Note: PANSA attempts to discover compatible WEBCARDLX and SNMPWEBCARD firmware, PowerAlert Local and previous versions of PowerAlert software, but
it does not search for PowerAlert Network Management System or other PowerAlert Network Shutdown Agents on the network.


Product specificaties

Merk: Tripp Lite
Categorie: UPS
Model: PowerAlert 12

Heb je hulp nodig?

Als je hulp nodig hebt met Tripp Lite PowerAlert 12 stel dan hieronder een vraag en andere gebruikers zullen je antwoorden




Handleiding UPS Tripp Lite

Handleiding UPS

Nieuwste handleidingen voor UPS