Tripp Lite PDUMV20HV Handleiding


Lees hieronder de 📖 handleiding in het Nederlandse voor Tripp Lite PDUMV20HV (24 pagina's) in de categorie Niet gecategoriseerd. Deze handleiding was nuttig voor 26 personen en werd door 2 gebruikers gemiddeld met 4.5 sterren beoordeeld

Pagina 1/24
1
Basic, Metered and Metered with
IsobarÂŽ Surge Protection Vertical
Rack PDUs
Models:
PDUMV30, PDUMV30HV, PDUV30HV, PDUV30-36,
PDUMV30-ISO, PDUMV20HV, PDUMV20HVL6,
PDUMV20HV-36, PDUV20HVL6-72
(Series Numbers: AGIB6672, AGPD6673, AGPD6674)
Important Safety Instructions 2
Important Warnings 2
Installation 4
Features 4
Warranty & Product Registration 6
EspaĂąol 7
Français 13
РусскиК 19
1111 W. 35th Street, Chicago, IL 60609 USA • tripplite.com/support
Copyright Š 2022 Tripp Lite. All rights reserved.
Owner’s Manual
WARRANTY REGISTRATION
Register your product today and be
automatically entered to win an ISOBAR
ÂŽ
surge protector in our monthly drawing!
tripplite.com/warranty
2
SAVE THESE INSTRUCTIONS
This manual contains instructions and warnings that should be
followed during the installation, operation and storage of this
product. Failure to heed these instructions and warnings will
void the product warranty.
CAUTION Only those who are properly trained or qualified to use this device
should do so. Anyone who is not trained or qualified should not use this device
unless it is under the supervision of someone who is properly trained or qualified
to do so. Children must be supervised to ensure that they do not use the device
as a toy.
Do not install this device if there is not at least 10 meters (30 feet) or more of wire
between the electrical outlet and the electrical service panel.
Never use the device if the cord and plug are damaged; if it is not working
properly, or if it has been dropped or damaged, take it to an authorized service
center for inspection and repair.
If the power cord is damaged, it must be replaced by the manufacturer, its
authorized service agent, or by qualified personnel in order to avoid a danger.
• The PDUMV30-ISO PDU model provides surge and line noise protection to connected
equipment through its outlets.
• Non-ISO PDUs do not provide surge and line protection to connected equipment.
• The PDU is designed for indoor use only in a controlled environment away from excess
moisture, temperature extremes, conductive contaminants, dust or direct sunlight.
• The PDU must be installed by a qualified technician only.
• Install in accordance with National Electrical Code standards. Be sure to use the proper
overcurrent protection for the installation, in accordance with the plug/equipment rating.
• Connect the PDU to an outlet that is in accordance with your local building codes and
adequately protected against excess currents, short circuits, and earth faults.
• Keep indoor ambient temperatures between 32°F and 77°F (0°C and 25°C).
• Use of this equipment in life support applications where failure of this equipment can
reasonably be expected to cause the failure of the life support equipment or to
significantly affect its safety or effectiveness is not recommended. Do not use this
equipment in the presence of a flammable anesthetic mixture with air, oxygen or nitrous
oxide.
• Do not connect the PDU to an ungrounded outlet or extension cords or adapters that
eliminate the connection to ground.
• The power requirement for each piece of equipment connected to the PDU must not
exceed the individual outlet’s load rating.
• The plug on the power supply cord serves as the disconnect device.
Important Safety Instructions
Important Warnings
3
Important Warnings
• The electrical outlets that supply power to the equipment should be near the equipment
and easily accessible.
• The total power requirement for equipment connected to the PDU must not exceed the
maximum load rating for the PDU.
• Do not drill into or attempt to open any part of the PDU housing. There are no user-
serviceable parts inside.
• Do not attempt to modify the PDU, including the input plugs and power cables.
• Do not attempt to use the PDU if any part of it becomes damaged.
• Do not attempt to mount the PDU to an insecure or unstable surface.
• Never attempt to install electrical equipment during a thunderstorm.
• Install in accordance with National Electrical Codes. Be sure to use the proper
overcurrent protection for the installation, in accordance with the plug rating/equipment
rating as follows:
Model Series Number Overcurrent Protection
PDUV30HV AGIB6672 30A
PDUV20HVL6-72 AGIB6672 20A
PDUMV30, PDUMV30-ISO AGPD6673 30A
PDUMV16HV, PDUMV20HV,
PDUMV20HVL6, PDUMV20HV-36
AGPD6674 20A
PDUMV30HV AGPD6675 30A


Product specificaties

Merk: Tripp Lite
Categorie: Niet gecategoriseerd
Model: PDUMV20HV
Kleur van het product: Zwart
Gewicht: 2360 g
Breedte: 57.2 mm
Diepte: 1619.2 mm
Hoogte: 95.2 mm
Snoerlengte: 3.05 m
Gewicht verpakking: 4310 g
Breedte verpakking: 88.9 mm
Diepte verpakking: 1663.7 mm
Hoogte verpakking: 127 mm
Materiaal behuizing: Aluminium
LED-indicatoren: Ja
Land van herkomst: China
Certificering: UL60950-1 (USA, Canada), NOM (Mexico), CE (IEC 60950)
Duurzaamheidscertificaten: RoHS
Temperatuur bij opslag: -15 - 50 °C
Hoogte, in bedrijf: 0 - 3000 m
Afmetingen (B x D x H): 57 x 95 x 1620 mm
Montage: Verticaal
(Buitenste) hoofdverpakking hoogte: 177.8 mm
(Buitenste) hoofdverpakking breedte: 406.4 mm
(Buitenste) hoofdverpakking brutogewicht: 27580 g
(Buitenste) hoofdverpakking lengte: 1676.4 mm
Hoeveelheid per (buitenste) hoofdverpakking: 6 stuk(s)
Rackcapaciteit: 0U
AC-ingangsfrequentie: 50 - 60 Hz
GTIN (EAN/UPC)-nummer (buitenste) hoofdverpakking: 10037332139341
Aantal AC uitgangen: 38 AC-uitgang(en)
Nominale input voltage: 200-240 V
Stopcontacttypes: C13 coupler,C19 coupler
Stroom (max.): 20 A
Input-connectietype: NEMA L6-20P, IEC-320 C20
PDU types: Gemeten
Netspanning, in bedrijf: 200-240 V

Heb je hulp nodig?

Als je hulp nodig hebt met Tripp Lite PDUMV20HV stel dan hieronder een vraag en andere gebruikers zullen je antwoorden




Handleiding Niet gecategoriseerd Tripp Lite

Handleiding Niet gecategoriseerd

Nieuwste handleidingen voor Niet gecategoriseerd