1. General information
•
Motion detector (PIR) for wall mounting in outdoor areas
(e.g. entrances, garages, etc.) of detached houses
•
The detector complies with EN 60669-2-1 when installed
as intended
•
Commissioning via mobile devices with app
theSenda Plug (iOS/Android)
•
Wireless networking of several detectors
•
Digital adjustment of the detection areas (app)
•
Various versions:
TECTA D180: Basic Detection area 180°, 12 m, poten-→
tiometer for follow-up time and brightness, no
Bluetooth BLE
TECTA D180i: Standard → Detection area 180°, 12 m,
with Bluetooth BLE, night programme, networkable
TECTA D280i: Performance → Detection area 280°,
16 m, with Bluetooth BLE, night programme, network-
able, light group control
•
Optional accessories:
Corner bracket 10 (9070969/9080031); spacer frame 10
(9070971/9080032)
2. Safety
Assembly and installation should only be carried
out by a qualied electrician, somebody who has
completed appropriate professional training and
has the knowledge and experience necessary to be
able to recognise and avoid the potential dangers
posed by electricity.
Before installation/disassembly, disconnect the
mains voltage and ensure that the parts are no
longer live.
Prior to commissioning and using the product, read
and observe all the operating instructions.
3. Proper use
•
Motion detector for automatic lighting control depending
on ambient brightness and detected movement
•
Suitable for wall mounting in outdoor areas (entrances,
garages, gardens, etc.)
4. Installation
Installation instructions
As the detector reacts to variations in temperature, avoid the
following situations:
Do not point the motion detector at objects with highly
reective surfaces such as windows, etc.
Do not install the motion detector near heat sources, such
as heating outlets, air conditioning systems, lamps, etc.
Do not direct the motion detector at objects that move in
the wind, such as large plants, etc.
Observe the direction of movement during the test run.
LIf necessary, make adjustments to the potentiometers
before installation (only for TECTA D180).
LObserve the recommended installation height on the wall
of 1.8–2.5 m (2.5–6 m for TECTA D280i)!
LEnsure a clear view, as infrared rays cannot penetrate solid
objects.
Disconnect power source.
Wall mounting
0FF
1
230V
2
If necessary, use optional corner bracket or spacer frame
for exible mounting.
Switch off the voltage .
Make markings for the holes on the wall and drill holes .
Ø 6 mm
60mm
3
Feed the cable through the seal of the plinth .
Fasten the plinth to the wall.
Tightene screws.
OROR
4
Connect the individual wires to the corresponding terminal
and tighten the screws .

2
OR
Click!
5
Click!
1010110/1010111
Place the motion detector on the plinth and snap into place
.
Detection area
r
t
TECTA D180 and TECTA D180i
Installation
height (A)
transverse (t)front-facing (r)
1.8 m10 m3 m
2.2 m12 m4 m
2.5 m14 m5 m
TECTA D280i
r
t
Installation
height (A)
transverse (t)front-facing (r)
2.5 m12 m5 m
3 m16 m6 m
3.5 m16 m6 m
4 m18 m7 m
4.5 m20 m7 m
5 m22 m7 m
6 m25 m10 m
Limiting the detection area
The detection area can be easily adjusted. The enclosed cover
clip can be used to hide unwanted areas and ensure targeted
monitoring.
Use the enclosed clipsto adjust the detector to the desired
detection area.
Remove the desired part of the clip.
Then place it on the lens.
TECTA D180 and TECTA D180i
2m
3m3m
No detection
3m
2nd layer with 20⁰ per segment
5m
4m4m
4m4m
no detection
completely covered –
no detection
covered up to 2 ~ 3 m
covered up to 3 ~ 4 m covered up to 4 ~ 5 m
TECTA D280i
Fully
3m
Lens mask installation alignment mark
completely covered
up to 3 m
Marking for alignment
3m
7m
covered up to 3 m covered up to 7 m
You can also easily set the area restriction in the app see
"Digital area restriction" Page 4.
5. Connection
!
Protect the device with an upstream circuit breaker type
B or C (EN 60898-1) of 10 A.

3
6. Settings via potentiometer
LIf the light switched by the detector shines very brightly
on the detector, the light can be switched on and off up to
5 times to calibrate the light measurement.
Only the TECTA D180 motion detector (1010100/1010101)
has 2 potentiometers for setting the brightness (LUX) and
run-on time (TIME).
Setting the brightness (LUX)
You can use the potentiometer for brightness to set various
brightness values (default setting5 lx).
Set the potentiometer to the desired switch-on brightness
(5–500 lux/on).
In the position, the detector always reacts to on/sun
movement, regardless of the brightness.
You can use the Teach-in function to memorise the brightness
values:
With the desired brightness, set the potentiometer to .
The new value is taught in after 15 seconds.
Leave the potentiometer at position .
LThe measured brightness value is inuenced by the instal-
lation location, the incidence of light, the position of the
sun, weather conditions, etc. Therefore, the lux values are
guide values.
Setting the time delay (TIME)
If the motion detector detects no further movement, it
switches off after the set time delay. If you want to change
the preset time (default setting 30 s)
Set the potentiometer to the desired time (e.g. 10 s, 30 s,
1 min, 10 min, 30 min).
If you want to use the pulse function (e.g. for a staircase light
timer)
Set the potentiometer to (0.5 s on, 10 s off).
Test detection area (test mode or walking test)
The test mode is used to test the detection area and to
restrict it if necessary.
Set the TIME potentiometer to .test
▻The motion detector only reacts to movements, bright-
ness measurement is switched off.
▻After the detector has detected a movement, it switches
on the connected light for the shortest follow-up time
(approx. 5 s). At the same time, the red LED on the
detector lights up for the duration of the detected
motion.
LIf the test mode is activated via the potentiometers, it
must also be deactivated via the potentiometers.
7. Align motion detector with sensor
head
The sensor head can be rotated 20° downwards and 90° to
the left and right (only with TECTA D280i).
45°
45°
20°
8. Settings via the app
TECTA D180i
TECTA D280i
theSenda Plug app
LBluetooth must always be activated on the mobile device!
Connect motion detector with mobile device
Open theSenda Plug app.
Select TECTA devices.
▻Devices are searched for and listed.
Select the desired device and press .Connect
▻The detector is now connected to the mobile device.
Product specificaties
| Merk: | Theben |
| Categorie: | Niet gecategoriseerd |
| Model: | TECTA D280i AN |
Heb je hulp nodig?
Als je hulp nodig hebt met Theben TECTA D280i AN stel dan hieronder een vraag en andere gebruikers zullen je antwoorden