Quick-Start Guide
To view manuals, FAQs, videos, drivers, downloads, technical drawings, and more, visit www.startech.com/support.
Manual Revision: July 3, 2019 1:35 PM
Product Diagram (HB30A7AME)
Component Function
12-Wire Terminal Block Used to connect an external DC Power Source
(7~48V DC Input) to the .Hub
2Screw Locks (x 8)
Used to securely lock a to the USB Device
USB-A Port Hub on the .
Center to center 19 Screw Lock Dimensions:
mm, thread size 4 - 40.
3Power LED : Indicates that the Hub is receiving Green
power.
4USB-B Host Port
Used to connect a to the .Host Computer Hub
Center to center 24 Screw Lock Dimensions:
mm, thread size 4 - 40.
5USB-A Ports (x 7)
Used to connect ( x 7) to the .USB Devices Hub
Used to charge connected .USB-A Devices
USB-A Ports support surge and 15KV ESD
(Electrostatic Discharge) Protection.
7-Port Industrial USB 3.0 (5 Gbps) Hub | USB 3.1 Gen 1 to 7x USB-A | ESD & Surge Protection
3
Requirements
For the latest requirements, please visit . www.startech.com/HB30A7AME
Phillips Head Screwdriver
Writing Utensil
Level
Mounting Screws (x 2)
Installation
Notes: It is recommended to use an external (+7 - 48V DC) DC Power Source
connected to the to ensure sucient power/current is 2-Wire Terminal Block
delivered to each on the . USB-A Port Hub
Powering the Hub Using the Universal Power Adapter
1. Connect the to the and to a Universal Power Adapter Terminal Block AC
Electrical Outlet.
2. Connect a (the end will depend on USB Port you are USB-B to USB Cable
connecting to) to the and to a USB port on the .USB-B Host Port Host Computer
3. The should detect the and automatically Host Computer’s Operating System Hub
install it.
4. Connect your to the (x 7) on the .USB Devices USB-A Ports Hub
Powering the Hub Using the 2-Wire Terminal Block
1. Remove the from the on the Terminal Block Connector Housing Terminal Block
Hub.
2. Using a small screwdriver (Phillips or Flat Head), loosen the screws on the Terminal
Block Connectors.
3. Connect the and from your (+7 - 48V DC) Power Ground Wires DC Power Source
to the proper , the terminals are marked on theTerminal Block Connectors Hub’s
Casing.
45
21
FCC Compliance Statement
This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to part 15 of the FCC
Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation.
This equipment generates, uses and can radiate radio frequency energy and, if not installed and used in accordance with the
instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not
occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be
determined by turning the equipment o and on, the user is encouraged to try to correct the interference by one or more of the
following measures:
Reorient or relocate the receiving antenna.
Increase the separation between the equipment and receiver.
Connect the equipment into an outlet on a circuit dierent from that to which the receiver is connected.
Consult the dealer or an experienced radio/TV technician for help
This device complies with part 15 of the FCC Rules. Operation is subject to the following two conditions:
(1) This device may not cause harmful interference, and (2) this device must accept any interference received, including
interference that may cause undesired operation. Changes or modications not expressly approved by StarTech.com could void
the user’s authority to operate the equipment.
Industry Canada Statement
This Class B digital apparatus complies with Canadian ICES-003.
Cet appareil numérique de la classe [B] est conforme à la norme NMB-003 du Canada.
CAN ICES-3 (B)/NMB-3(B)
This device complies with Industry Canada licence-exempt RSS standard(s). Operation is subject to the following two conditions:
(1) This device may not cause interference, and (2) This device must accept any interference, including interference that may
cause undesired operation of the device.
Le présent appareil est conforme aux CNR d’Industrie Canada applicables aux appareils radio exempts de licence. L’exploitation
est autorisée aux deux conditions suivantes:
(1) l’appareil ne doit pas produire de brouillage, et (2) l’utilisateur de l’appareil doit accepter tout brouillage radioélectrique subi,
même si le brouillage est susceptible d’en compromettre le fonctionnement.
Use of Trademarks, Registered Trademarks, and other Protected Names and Symbols
This manual may make reference to trademarks, registered trademarks, and other protected names and/or symbols of third-
party companies not related in any way to StarTech.com. Where they occur these references are for illustrative purposes only
and do not represent an endorsement of a product or service by StarTech.com, or an endorsement of the product(s) to which
this manual applies by the third-party company in question. StarTech.com hereby acknowledges that all trademarks, registered
trademarks, service marks, and other protected names and/or symbols contained in this manual and related documents are the
property of their respective holders.
Warranty Information
This product is backed by a two-year warranty.
For further information on product warranty terms and conditions, please refer to .www.startech.com/warranty
Limitation of Liability
In no event shall the liability of StarTech.com Ltd. and StarTech.com USA LLP (or their ocers, directors, employees or agents)
for any damages (whether direct or indirect, special, punitive, incidental, consequential, or otherwise), loss of prots, loss of
business, or any pecuniary loss, arising out of or related to the use of the product exceed the actual price paid for the product.
Some states do not allow the exclusion or limitation of incidental or consequential damages. If such laws apply, the limitations
or exclusions contained in this statement may not apply to you.
Safety Measures
If product has an exposed circuit board, do not touch the product under power.
Mesures de sécuri
Si l’un des circuits imprimés du produit est visible, ne pas touchez le produit lorsqu’il est sous tension.
安全対策
• 製品に露出した状態の回路基盤が含まれる場合、電源が入っている状態で製品に触らないでください
Misure di sicurezza
Se il prodotto ha un circuito stampato visibile, non toccare il prodotto quando è acceso.
Säkerhetsåtgärder
Rör aldrig vid enheter med oskyddade kretskort när strömmen är påslagen.
FR: startech.com/fr
DE: startech.com/de
ES: startech.com/es
NL: startech.com/nl
IT: startech.com/it
JP: startech.com/jp
StarTech.com Ltd.
45 Artisans Cres
London, Ontario
N5V 5E9
Canada
StarTech.com Ltd.
Unit B, Pinnacle 15
Gowerton Rd,
Brackmills
Northampton
NN4 7BW
United Kingdom
StarTech.com LLP
2500 Creekside
Parkwy
Lockbourne, Ohio
43137
U.S.A.
Din Rail Mounting
Wall Mounting
It is recommend that you use when wall mounting the .Wall Studs Hub
1. Align the on the wall in the position you want to mount the .Hub Hub
2. Using a mark o both of the .Writing Utensil Mounting Holes
3. Align the on the with the .Mounting Holes Hub Mounting Hole Marks
4. Insert the (x 2) through the and into the Mounting Screws Wall Mounting Holes
Wall.
5. Using a tighten the until the is Phillips Head Screwdriver Mounting Screws Hub
securely fasten to the .Wall
Note: Ensure the polarity of the input power is correctly matched with the Terminal
Block Pins to ensure proper function.
Terminal Block Pins
4. Insert the onto the .Terminal Block Housing Hub’s Casing
Mounting
DIN Rail Mounting
1. Align the (x 2) with the (x 4) on the back of the Din Rail Brackets Mounting Holes
Hub.
2. Insert the (x 4) through the and into the .Mounting Screws Din Rail Brackets Hub
3. Using a tighten the . Be careful not to Phillips Head Screwdriver Mounting Screws
over-tighten the . Mounting Screws
4. Clip the onto a securing the to the .Din Rail Brackets Din Rail, Hub Din Rail


Product specificaties

Merk: StarTech.com
Categorie: Niet gecategoriseerd
Model: HB30A7AME
Kleur van het product: Zwart
Gewicht: 326 g
Breedte: 55 mm
Diepte: 145 mm
Hoogte: 45 mm
Gewicht verpakking: 1300 g
Breedte verpakking: 190 mm
Diepte verpakking: 294 mm
Hoogte verpakking: 70 mm
LED-indicatoren: Stroom
Stroom: 1.4 A
Meegeleverde kabels: USB
Inclusief AC-adapter: Ja
Certificering: RoHS, REACH, CE, FCC, TAA
Plug and play: Ja
Aantal per verpakking: 1 stuk(s)
Ingangsspanning: 100 - 240 V
Soort voeding: AC
Temperatuur bij opslag: -20 - 85 °C
Aantal poorten USB 3.2 Gen 1 (3.1 Gen 1) Type A: 7
Output current: 3.25 A
Spanning: 20 V
Snelle installatiehandleiding: Ja
Mean time between failures (MTBF): 126106 uur
Hostinterface: USB 3.2 Gen 1 (3.1 Gen 1) Type-B
Chipset: Genesys Logic - GL3523
(Buitenste) hoofdverpakking hoogte: 315 mm
(Buitenste) hoofdverpakking breedte: 400 mm
(Buitenste) hoofdverpakking lengte: 520 mm
Hoeveelheid per (buitenste) hoofdverpakking: 14 stuk(s)
Overdrachtssnelheid: 5000 Mbit/s
Stroomverbruik (typisch): 65 W
Bedrijfstemperatuur (T-T): 0 - 70 °C
Relatieve vochtigheid in bedrijf (V-V): 5 - 95 procent
Code geharmoniseerd systeem (HS): 84719000
Aantal poorten: 7
Spanningsbeveiliging: Ja
Inbegrepen soorten voedingsstekkers: ANZ, EU, JP, NA, UK
Hub-interfaces: USB 3.2 Gen 1 (3.1 Gen 1) Type-A
Klemmenblokpoort: Ja
UASP-ondersteuning: Ja
DIN-railset inbegrepen: Ja

Heb je hulp nodig?

Als je hulp nodig hebt met StarTech.com HB30A7AME stel dan hieronder een vraag en andere gebruikers zullen je antwoorden




Handleiding Niet gecategoriseerd StarTech.com

Handleiding Niet gecategoriseerd

Nieuwste handleidingen voor Niet gecategoriseerd