Sony XM-5ES Handleiding


Lees hieronder de 📖 handleiding in het Nederlandse voor Sony XM-5ES (47 pagina's) in de categorie Hifi systeem. Deze handleiding was nuttig voor 51 personen en werd door 2 gebruikers gemiddeld met 4.5 sterren beoordeeld

Pagina 1/47
XM-5ES
5-038-864-11(1)
5-Channel Power
Amplifier
Owner’s Record
The model and serial numbers are located on the bottom of the unit.
Record the serial number in the space provided below.
Refer to these numbers whenever you call upon your Sony dealer
regarding this product.
Model No. XM-5ES
Serial No.
Operating Instructions GB
Mode d’emploi FR
Bedienungsanleitung DE
Manual de instrucciones ES
Gebruiksaanwijzing NL
Bruksanvisning SE
5GB
Power Amplifier
Ventilation outlet
Dissipates heat.
Depending on the temperature of the amplifier,
the fan operates in one of the three statuses:
stopped, low-speed, high-speed.
Heat sink cover
The direction of the heat sink cover can be
changed according to your preference (page 9).
Status indicator light
Lights up in white during operation.
If the protection circuit activates, the status
indicator light changes from white to red. For
details, see “Troubleshooting” (page 18).
TURN-ON switch
Selects the turn-on mode of the amplifier.
REMOTE”: Select this for remote turn-on
mode. The amplifier turns on when a turn-on
signal is received from the REMOTE terminal.
See “REMOTE terminal” (page 11) for details.
SIGNAL”: Select this for high-level sensing
turn-on mode. The amplifier turns on when a
turn-on signal is received from the INPUT
connector. This feature is only available for
high-level (speaker level) input connection.
See “REMOTE terminal” (page 11) for details.
Guide to Parts and Controls
Control Panel (Top Panel)
TURN-ON
REMOTE SIGNAL
INPUT MODE
1-4
1
CH 1-4
1
-2
1
+ +3/2 4
BRIDGED
CH 1 CH 2
5
5+6
SUB CH
1
+2
3+4
LINE OUT MODE
THRU ALL
STEREO
CH 3/4 SUB CH
BRIDGED
CH 3 CH 4
REMOTE
+
12 V
GROUND
L R L R
SUB CH
50-
500
FILTER RANGE (
Hz)
HPF (
Hz)
OFF BP
HP LP
500-
5k 500
150
50
1.5k
LPF (
Hz)
500
150
50050
5k
500
5k
1.5k
INPUT SENS
50-
500
FILTER RANGE (
Hz)
HPF (
Hz)
OFF BP
HP LP
500-
5k 500
150
50
1.5k
LPF (
Hz)
500
150
50050
5k
500
5k
1.5k
INPUT SENS
CH 1/2
INPUT SENS
OFF ON
150
50050
OFF ON
30
SUBSONIC FILTER (
Hz)
505
LPF (Hz)
TU RN-ON
REMOTE SIGNAL
50-
500
INPUT MODE
1-4
1
CH 1-4
1
-2
1
+ +3/2 4
FILTER RANGE (
Hz)
BRIDGED
HPF (
Hz)
OFF BP
HP LP
CH 1 CH 2
5
5+6
SUB CH
1
+2
3+4
LINE OUT MODE
THRU ALL
ST EREO
500-
5k 500
150
50
1.5k
LPF (
Hz)
500
150
50050
5k
500
5k
1.5k
INPUT SENS
CH 3/4 SUB CH
BRIDGED
CH 3 CH 4
REMOTE
+
12 V
GROUND
L R L R
SUB CH
50-
500
FILTER RANGE (
Hz)
HPF (
Hz)
OFF BP
HP LP
500-
5k 500
150
50
1.5k
LPF (
Hz)
500
150
50050
5k
500
5k
1.5k
INPUT SENS
CH 1/2
INPUT SENS
OFF ON
150
LPF (
Hz)
50050
OFF ON
30
SUBSONIC LTER (
Hz)
505
ȫ
ȩ
Ȫ
Ȭ ȵ ȷȶȭ Ȯ ȯ ȹȸ
Ȱ
ȱ ȳ
Ȳ ȴ
Ȱȱ ȳ
Ȳ ȴ
Ⱥ Ȼ
6GB
INPUT MODE section:
CH 1-4 switch
Selects the input mode for CH 1, CH 2, CH 3 and
CH 4.
“1-4”: For 4-channel stereo input.
“1”: For 1-channel input.
“1-2”: For 2-channel input.
“1+3/2+4”: For 4-channel input.
SUB CH switch
Selects the input mode for SUB CH (subwoofer
channel).
“5”: For mono subwoofer input.
“5+6”: For stereo subwoofer input.
“1+2”: Uses signal input from INPUT 1+2.
“3+4”: Uses signal input from INPUT 3+4.
LINE OUT MODE switch
Sets the mode of signal output to LINE OUT 1
and 2 connectors. Signal output from all LINE
OUT connectors are unfiltered and not affected
by any FILTER settings.
“THRU”: Stereo output (through mode)
STEREO”: Stereo output (summing mode)
“ALL”: Mono output (summing mode)
CH 1/2 and CH 3/4 section:
FILTER switch
Sets the filter mode for CH 1/2 and CH 3/4.
“OFF”: Turns the filter off.
HP” (high-pass): Frequencies lower than HPF
control setting are filtered.
LP” (low-pass): Frequencies higher than LPF
control setting are filtered.
“BP” (band-pass): The range of frequency for
the HPF control is automatically fixed at 50 Hz
– 500 Hz; the range of frequency for LPF
control is automatically fixed at 500 Hz – 5
kHz. Frequencies outside the range of HPF
and LPF settings are filtered.
RANGE switch
Sets the range of frequency for HPF (high-pass
filter) and LPF (low-pass filter) control.
50-500”: Range of frequency for subwoofer.
500-5k”: Range of frequency for midrange
speaker or tweeter.
HPF (high-pass filter) control
Depending on the RANGE setting, adjusts the
cutoff frequency in the range of 50 Hz – 500 Hz
or 500 Hz – 5 kHz.
LPF (low-pass filter) control
Depending on the RANGE setting, adjusts the
cutoff frequency in the range of 50 Hz – 500 Hz
or 500 Hz – 5 kHz.
INPUT SENS (input sensitivity) control
Adjusts the input level sensitivity for CH 1/2 and
CH 3/4.
Turn the knob clockwise when the output level
of the connected audio devices is low.
SUB CH section:
SUBSONIC FILTER switch
Turns the subsonic filter on or off.
SUBSONIC FILTER control
Adjusts the cutoff frequency (5 Hz – 50 Hz) of the
subsonic filter.
LPF (low-pass filter) switch
Turns the low-pass filter on or off.
LPF (low-pass filter) control
Adjusts the cutoff frequency (50 Hz – 500 Hz) of
the low-pass filter.
INPUT SENS (input sensitivity) control
Adjusts the input level sensitivity for SUB CH.
Turn the knob clockwise when the output level
of the connected audio devices is low.
SPEAKER OUT terminal screw head
+12 V terminal screw head
REMOTE terminal screw head
GROUND terminal screw head
INPUT 1 CH 1
INPUT 2 CH 2
INPUT 3 CH 3
INPUT 4 CH 4
INPUT 1 CH 1
CH 2
CH 3
CH 4
INPUT 1 CH 1
CH 3
INPUT 2 CH 2
CH 4
INPUT 1 CH 1
INPUT 3 CH 3
INPUT 2 CH 2
INPUT 4 CH 4
INPUT 5 SUB CH
INPUT 5 SUB CH
INPUT 6
INPUT 1 SUB CH
INPUT 2
INPUT 3 SUB CH
INPUT 4
INPUT 1 LINE OUT 1
INPUT 2 LINE OUT 2
INPUT 1 LINE OUT 1
INPUT 3
INPUT 2 LINE OUT 2
INPUT 4
INPUT 1
INPUT 2 LINE OUT 1
INPUT 3 LINE OUT 2
INPUT 4


Product specificaties

Merk: Sony
Categorie: Hifi systeem
Model: XM-5ES

Heb je hulp nodig?

Als je hulp nodig hebt met Sony XM-5ES stel dan hieronder een vraag en andere gebruikers zullen je antwoorden




Handleiding Hifi systeem Sony

Handleiding Hifi systeem

Nieuwste handleidingen voor Hifi systeem