Simrad StructureScan 3D Module Handleiding

Simrad Niet gecategoriseerd StructureScan 3D Module

Bekijk gratis de handleiding van Simrad StructureScan 3D Module (2 pagina’s), behorend tot de categorie Niet gecategoriseerd. Deze gids werd als nuttig beoordeeld door 5 mensen en kreeg gemiddeld 4.3 sterren uit 3 reviews. Heb je een vraag over Simrad StructureScan 3D Module of wil je andere gebruikers van dit product iets vragen? Stel een vraag

Pagina 1/2
204 mm (8.03")
169 mm (6.63")
TRANSDUCER1 TRANSDUCER2
NET-3NET-1POWER
12V/24V 3A
NET-2
91 mm
(3.58")
180 mm
57 mm (2.24")
207 mm
183 mm (7.20")
Dimensions
MountingParts included
DESCRIPTION
1StructureScan® 3D module
2Installation screws
3Ethernet cable, 4 m (15 ft)
4Power cable, 2 m (6.6 ft)
5Fuse and Fuse holder
6StructureScan® 3D Transducer (Optional)
StructureScan®3D
Installation Guide
For technical speci cations and
declarations, refer to the product
website on:
*988-10970-001*
simrad-yachting.com
lowrance.com
TRANSDUCER1 TRANSDUCER2
NET-3NET-1POWER
12V/24V 3A
NET-2
TRANSDUCER1 TRANSDUCER2
NET-3NET-1POWER
12V/24V 3A NET-2
TRANSDUCER1 TRANSDUCER2
NET-3NET-1POWER
12V/24V 3A
NET-2
TRANSDUCER1 TRANSDUCER2
NET-3NET-1POWER
12V/24V 3A
NET-2
1 2 3 4 5 6
TRANSDUCER1 TRANSDUCER2
NET-3NET-1POWER
12V/24V 3A
NET-2
Power
Connectors and LEDs
Wiring example
Transducer connection
TRANSDUCER1 TRANSDUCER2
NET-3NET-1POWER
12V/24V 3A
NET-2
TRANSDUCER1 TRANSDUCER2
NET-3NET-1POWER
12V/24V 3A
NET-2
Switch
12 / 24 V DC
+
_
Red
Yellow
Blue
(n/c)
Blue
(n/c)
Blue
(n/c)
Red
Black
Yellow Red
Yellow
+
_
Power
Control bus
To Multi-Function
Display
12 / 24 V DC
1
2
3 3
TRANSDUCER1 TRANSDUCER2
NET-3NET-1POWER
12V/24V 3A
NET-2
ID CONNECTORS LEDs
1Ethernet
OFF No connection
ON/FLASHING - Green Connected and ok
2Power
OFF No power
ON - Red System starting
ON - Green System operating
FLASHING Red/Green
Software error - restart
unit
3
Structure Scan
3D transducer
OFF Sounder not operating
FLASHING (every second) -
Green
Searching for bottom
signal
ON
Operational system with
bottom signal detected
Power controlled by External Switch Power controlled by Multi-Function Display
12/24 V DCStructureScan® 3D Module
StructureScan® 3D Transducer
StructureScan® 3D Transducer cable 1
to
Transducer 1 Connector
StructureScan® 3D Transducer cable 2
to
Transducer 2 Connector
4G Radar
Multi-Function Displays
TRANSDUCER1 TRANSDUCER2
NET-3NET-1POWER
12V/24V 3A
NET-2
Ensure both StructureScan® 3D transducer cables
are connected to the StructureScan® 3D Module correctly


Product specificaties

Merk: Simrad
Categorie: Niet gecategoriseerd
Model: StructureScan 3D Module

Heb je hulp nodig?

Als je hulp nodig hebt met Simrad StructureScan 3D Module stel dan hieronder een vraag en andere gebruikers zullen je antwoorden