• Support up to 2400W PDB Design to fit for 2 vertical CRPS power supply
to install on the chassis.
• Mylar insulation included that to prevent the PDB board shortcut
• Using an Amphenol-manufactured card edge connector with 3-beam contact design
to ensure stable power output.
• Perfectly fit for GM2000C-TFU and GM2400C-TFU CRPS PSU
• Full modular design with all black flat cable included.
Nvidia/AMD graphic cards.
• PDB followed Fire Resistant (UL 94V-0) standard
• The PDB is designed with a PMBus connector to enable administrators toconveniently
monitor and read power status signals.
• Multiple protection circuitry
2400W 1U 1+1 Redundant CRPS
Fully Modular Power Distribution Board with Cage
CPB Series
1
SPECIFICATION
SilverStone CPB Series
CPB01
SST-CPB01
1U 1+1 Redundant CRPS Fully Modular Power
distribute board with cage
1.1 DC Input Requirements
1.2 Efficiency
The Backplane must be capable of operating with the following Conditions
The power supply must have a minimum of 88% efficiency measured at the worst case condition.
All outputs must maintain their regulation within the below limits when measured at the output
connector point or across the remote sense (if applicable) in any load condition defined in
section 2.2
This specification defines the performance characteristics of a 1U redundant power supply back panel.
Its operation temperature is at 50 degrees Celsius and the total output reaches to 2400W.
2.1 DC voltage regulation
1. Input Requirement
2. Output Requirements
MinimumNominalMaximumUnit
Table 1.1
Vdc
Input Voltage
Range(Vdc)
11.7112.212.69
OutputMinimumNominalMaximumUnit
+12V11.4012.0012.60Vdc
+5V4.755.05.25Vdc
+3.3V3.143.33.47Vdc
-12V10.8012.013.2Vdc
+5Vsb4.755.05.25Vdc
Table 2.1
2
2.2 Output Current Requirements
2.3 Output Ripple and Noise
2.4 Output Dynamic Loading
All outputs must maintain their regulation as per section 2.1 when loaded to the
following loading combination:
1. Maximum continuous combined load on +3.3V and +5V outputs shall not
exceed 150W.
2. The total output power can not exceed 2400W continuously. During load
changes from minimum to maximum or maximum to minimum the unit must
not shut down.
The following output ripple/noise requirements will be met throughout the load
ranges specified in Section 2.2 and under all input voltage conditions specified
in Section 2.1. Ripple and noise are defined as periodic or random signals over
the frequency band of 10Hz to 20MHz. Measurements will be made with an
oscilloscope set to 20MHz bandwidth limit. Measurement is done by using
10uF Tantalum in parallel with a 0.1uf ceramic capacitor, measured directly
at the output connector side.
OutputMinimumMaximumUnit
+12V0.5200A
+5V0.522A
+3.3V0.525A
-12V00.3A
+5Vsb0.13.0A
Table 2.2
The output voltages shall remain within the limits specified in 2.2 for the step
loading and within the limits specified
in 2.6 for the capacitive loading. The load transient repetition rate shall be
tested between 50Hz and 5kHz at duty
cycles ranging from 10%-90%. The load transient repetition rate is only a test
specification. The step load mayΔ
occur anywhere within the MIN load to the MAX load shown in 2.5.