Seiko S058 Handleiding

Seiko Horloge S058

Lees hieronder de 📖 handleiding in het Nederlandse voor Seiko S058 (5 pagina's) in de categorie Horloge. Deze handleiding was nuttig voor 18 personen en werd door 2 gebruikers gemiddeld met 4.5 sterren beoordeeld

Pagina 1/5
1
SEIKO DIGITAL STOPWATCH Cal. S058
NOTES ON THE BATTERY
Do not remove the battery from the stopwatch.
If it is necessary to take out the battery, keep it out of the reach of children. If a child swallows it, consult a doctor immediately.
Never short-circuit, heat or otherwise tamper with the battery, and never expose it to fire. The battery may burst, become very
hot or catch fire.
The battery is not rechargeable. Never attempt to recharge it, as this may cause battery leakage or damage to the battery.
WARNING
NOTES ON THE STRAP
The stopwatch has a strap for wearing it around your neck. Take good care lest it should be caught by something near you
or wind around your neck.
Please also note that the strap may damage your clothes, or injure your hands, neck or other parts of your body.
You are now the proud owner of a SEIKO Digital Stopwatch Cal. S058. For best results, please read the
instructions in this booklet carefully before using your SEIKO Digital Stopwatch. Please keep this manual handy
for ready reference.
TO PRESERVE THE QUALITY OF YOUR STOPWATCH
WATER RESISTANCE (5 bar)
Your stopwatch is designed and manufactured to withstand up to 5
bar, such as accidental contact with splashes of water or rain. Do not
operate the buttons when the stopwatch is wet or in water.
TEMPERATURES
If the stopwatch is left in direct sunlight for a long time, the display
may become black, but this condition will be corrected when the
stopwatch returns to normal temperature.
Do not leave your stopwatch in very low temperatures below -10ºC
(+14ºF) for a long time since the cold may cause:
a. a slight time loss or gain.
b. the change of digits to become slow.
c. the display light to dim.
However, the above conditions will be corrected when the stopwatch
returns to normal temperature.
SHOCKS
Do not subject it to violent shocks.
MAGNETISM
Your stopwatch will not be affected by magnetism.
CHEMICALS
Be careful not to expose the stopwatch to solvents, mercury, cosmetic
spray, detergents, adhesives or paints. Otherwise, the case, etc. may
become discolored, deteriorated or damaged.
PERIODIC CHECK
It is recommended that the stopwatch be checked once every 2 to 3
years. Have your stopwatch checked by an AUTHORIZED SEIKO
DEALER or SERVICE CENTER to ensure that the case, buttons, gasket
and crystal seal remain intact.
PRECAUTION REGARDING CASE BACK PROTECTIVE FILM
If your stopwatch has a protective film and/or a sticker on the case back,
be sure to peel them off before using it.
STATIC ELECTRICITY
The IC (Integrated Circuit) used in your stopwatch will be affected by
static electricity which may disturb the display. Keep your stopwatch
away from close contact with objects such as TV screens which emit
strong static electricity.
LIQUID CRYSTAL PANEL
The normal life expectancy for a liquid crystal panel is approximately
7 years. After that it may decrease in contrast, becoming difficult to
read.
Please contact your AUTHORIZED SEIKO DEALER or SERVICE CENTER
if you wish to have a new panel fitted (guaranteed one year).
The SEIKO quartz Stopwatch Cal. S058 is a digital stopwatch featuring a lap/split time memory function that can store and recall up to 100 lap/split time data.
A double repeat timer function, a time/calendar function as well as a daily alarm function are also provided. In addition, it has a built-in LED backlight that enables
you to view the display in darkness.
FEATURES
STOPWATCH
The stopwatch can measure up to 100 hours in 1/100 seconds.
LAP TIME, LAP TIME IN PROGRESS AND SPLIT TIME DISPLAYS
Three separate stopwatch displays are available for lap time, lap time in progress and split time
measurements.
MEMORY FUNCTION
Up to 100 lap/split time data can be stored in memory, and they can be recalled either during or after the
measurement.
TIME/CALENDAR
Year, month, day, date, hour, minutes and seconds are displayed.
The calendar automatically adjusts for odd and even months including February of leap years from January
1, 2006 to December 31, 2055.
DOUBLE REPEAT TIMER
The built-in two descending timers (which allow you to set two different timer times) can be used
repeatedly one after the other.
Each Timer 1 and Timer 2 can be set for any desired amount of time from 10 seconds up to 99 hours,
59 minutes and 59 seconds in one-second increments.
For easy distinction between Timer 1 and Timer 2, the time-up warning beeps are different in tones.
ALARM
The daily alarm sounds once at the designated time (hour, minute) every 24 hours.
BUILT-IN LED LIGHT
By pressing the designated button once, the light illuminates the display for approximately 3 seconds.
Through the light guide panel, the light from the LED (Light Emitting Diode) is evenly dispersed over the
entire display.
AUTOMATIC SHUT-OFF FUNCTION (ECO)
When the stopwatch is left untouched for one hour, the display automatically becomes blank in order to
minimize battery consumption.
A
B
C
D
DISPLAY AND BUTTONS
E
Built-in LED light
Press Button E to turn the
light on for approximately 3
seconds.
2
* If Buttons A, B, C and D are pressed at the same time, all the data in memory will be erased. Refer to "HOW TO RESET THE BUILT-IN IC" on page 5 for further details.
CHANGE OF DISPLAYS
Press Button D to change the display mode.
B
AC
“A” (AM)/“P” (PM) mark Hour
Year
Month
D
Date
Day
Seconds
Minutes
* With each press of Button C in TIME/CALENDAR
display, the confirmation sound for button
operation is alternately switched "ON" and "OFF."
While the confirmation sound for button operation
is set to "ON," the mark appears on display.
Confirmation sound
for button operation
TIME/CALENDAR SETTING
The DAY is automatically set once the YEAR, MONTH and DATE are set.
To quit the time/calendar setting, press Button B. When the stopwatch is left untouched in the TIME/CALENDAR SETTING display, it automatically returns to the
TIME/CALENDAR display within two to three minutes.
The calendar adjusts automatically for odd and even months including February of leap years from January 1, 2006 to December 31, 2055.
When setting the HOUR digits in the 12-hour indication, check that “A” (AM)/“P” (PM) mark is correctly set. In the 24-hour indication, no mark is displayed.
If Button A and C are pressed simultaneously, all the digital segments light up. This is not a malfunction. Press any of Button A, B, C or D to return to the TIME/
CALENDAR display.
Press to show the TIME/CALENDAR display.
Press and hold for 2 seconds to show the TIME/CALENDAR SETTING display.
Press repeatedly to select the digits (flashing) to be adjusted.
Press to set the flashing digits or reset the SECONDS to “00.”
* The DAY disappears and the SECOND digits start flashing.
* The digits move quickly if Button A is kept pressed.
12-/24-hour indication setting:
Change between 12- and 24-hour indications is made alternately with each press of Button A.
Automatic shut-off function setting (ECO):
With each press of Button A, the automatic shut-off function is alternately set to "ON" and
"OFF."
After all the adjustments are completed, press to return to the TIME/CALENDAR
display.
D
B
C
A
B
MINUTES
YEAR
12-/24-HOUR INDICATION
MONTH
HOURSECONDS DATE(DAY)
AUTOMATIC SHUT-OFF (ECO)
The stopwatch can measure up to 100 hours in 1/100 second increments.
Three separate measurement displays are available; lap time, lap time in progress and split time displays.
[LAP TIME IN PROGRESS display] [SPLIT TIME display]
[LAP TIME display]
AC
B
D
“LAP” mark Lap No.
Lap time
Accumulated
elapsed time
A C
B
D
“RLP” mark Lap No.
Lap time
A C
B
D
“SPL” mark Split No.
Accumulated
elapsed time
Split time
Lap time
in progress
STOPWATCH
TIME/CALENDAR
display
STOPWATCH
<LAP TIME>
display
STOPWATCH
<LAP TIME IN PROGRESS>
display
STOPWATCH
<SPLIT TIME>
display
TIMER
display
D
D
D
D
D
D
ALARM
display
3
Before using the stopwatch, be sure to reset the digits to “00.”
When the stopwatch is stopped, press Button A.
When it is counting, press Button C to stop the measurement and then press Button A.
1 Standard measurement
Press to show the LAP TIME, LAP TIME IN PROGRESS or SPLIT TIME display.
D
C AC
START STOP RESET
STOPWATCH OPERATION
ABC
D
2 Accumulated elapsed time measurement
Press to show the LAP TIME, LAP TIME IN PROGRESS or SPLIT TIME display.
D
C CC
START STOP RESTART
C
STOP
A
RESET
3 Lap time measurement
Press to show the LAP TIME or LAP TIME IN PROGRESS display.
D
* Restarting and stopping the stopwatch can be repeated by pressing Button C.
A AC
START LAP 1 LAP 2
C
FINISH
A
RESET
* Lap time measurement can be repeated by pressing Button A.
Split time
Lap time
Start
* “Lap time” is the time that has elapsed from the start of
one stage of an activity to that of the next stage.
“Split time is the time that has elapsed from the start of
an activity to any given stage.
In the LAP TIME display, the previous lap time is displayed in the upper row while the
accumulated elapsed time is displayed in the lower row during measurement.
In the LAP TIME IN PROGRESS display, the previous lap time is displayed in the upper
row while the current lap time measurement is displayed in the lower row during
measurement.
Lap No. for the previous lap
Lap time for the previous lap
Accumulated elapsed time
Lap time in progress
Lap No. for the previous lap
Lap time for the previous lap
4 Split time measurement
A AC
START SPLIT 1 SPLIT 2
C
FINISH
A
RESET
* Split time measurement can be repeated by pressing Button A.
D
A C
Lap time
Split time
Lap/split No.
Flashing mark appears
while the measurement is in progress.
If no lap time/split time measurement is made in the STOPWATCH display and no data is stored in memory, the display
shown at right will appear when the display is changed over to the MEMORY RECALL.
Even if the stopwatch is reset to “00,” stored data is not erased and can be recalled unless a new measurement is started.
The stopwatch can measure the lap time/split times as many times as necessary, but only the first 100 data will be stored
in memory.
5 How to use the memory function
Up to 100 lap/split time data can be stored and recalled either during or after
measurement.
Press to show the MEMORY RECALL display.
* In memory recall after measurement, the oldest measurement stored in memory is
displayed first. In memory recall during measurement, the newest one is displayed first.
With each press, the stored data is recalled successively from the oldest to the
newest.
With each press, the stored data is recalled successively from the newest to the
oldest.
or
Press to return to the STOPWATCH display.
Press to show the SPLIT TIME display.
D
B
C
A
B


Product specificaties

Merk: Seiko
Categorie: Horloge
Model: S058

Heb je hulp nodig?

Als je hulp nodig hebt met Seiko S058 stel dan hieronder een vraag en andere gebruikers zullen je antwoorden




Handleiding Horloge Seiko

Handleiding Horloge

Nieuwste handleidingen voor Horloge