Inventory
Safety and General Information
Inspect the package contents upon receipt. Notify the
carrier and dealer if there is any damage.
Read the Safety Guide supplied with this unit before installing the
UPS.
This UPS is intended for indoor use only.
Do not operate this UPS in direct sunlight, in contact with fluids, or where there is
excessive dust or humidity.
Be sure the air vents on the UPS are not blocked. Allow adequate space for proper
The battery typically lasts for two to three years. Environmental factors impact
battery life. Elevated ambient temperatures, poor quality AC power, and frequent
short duration discharges will shorten battery life.
Connect the UPS power cable directly to a wall outlet. Do not use surge protectors
or extension cords.
Specifications
Connect the Battery
The Back-UPS is shipped with one battery cable disconnected. Remove the Stop!
Connect the Battery label that covers the outlets. Prior to connecting any equipment
to the unit, connect the battery cable to the unused battery terminal. It is normal for
small sparks to be seen when the battery cable is connected to the battery terminal.
Wall Mount Installation
Horizontal installation, use 2 screws 7.3" (186.3 mm) apart.
Vertical installation, use 2 screws 5.4" (137.2 mm) apart.
Allow 5/16 (8 mm), of the screw to protrude from the wall.
Replace Battery
Use only approved APC by Schneider Electric replacement battery cartridges.
Deliver used batteries to a battery replacement facility in the packaging provided by
APC by Schneider Electric with the replacement battery cartridge. To order
replacement battery cartridges contact APC by Schneider Electric.
Connect Equipment
Battery Backup + Surge Protection outlets
Battery backup outlets provide protection to connected equipment when the
Back-UPS is turned on and connected to AC power.
Battery backup outlets receive power from the Back-UPS for a limited period of time
when a power outage, or brownout condition occurs.
Battery backup outlets provide protection from power surges or spikes.
Connect a computer, monitor and other peripheral devices to the outlets.
Surge Protection outlets
Surge protection outlets provide protection to connected equipment when the
Back-UPS is connected to AC power, and is switched on or off.
Surge protection outlets provide protection from power surges or spikes.
Connect a printer, scanner or other peripheral devices to the surge protection outlets.
Connect telephone line
The Back-UPS protects equipment connected to a telephone line from power surges
when connected through the Back-UPS coaxial connectors.
PowerChute
Personal Edition Software
Overview
Use PowerChute Personal Edition software to configure the UPS settings.
Protect your computer and other equipment during a power outage. During a power
outage, PowerChute will save any open files on your computer and safely shut it
down. When power is restored, it will restart the computer.
Configure the UPS to use features such as power-saving outlets, shutdown
configuration, and alarms.
Monitor the UPS for power usage and power events.
Note: PowerChute is only compatible with a Windows operating system. If you are
using a Mac OSX, use the native shutdown feature to protect your system. See the
documentation provided with your computer.
Installation
Use a USB cable to connect the Data port on the rear panel of the UPS to the USB port
on your computer.
If the Back-UPS came with CD into your computer and a PowerChute CD, insert the
follow the on-screen instructions.
If the Back-UPS did not come with a PowerChute CD, go to www.apc.com and
download the software free of charge.
Turn On the Back-UPS
Press the POWER ON button located on the top of the Back-UPS. The Power On/
Replace Battery LED will illuminate and a single short beep will be audible to
indicate that the Back-UPS is providing protection for connected equipment.
The Back-UPS battery charges fully during the first 16 hours while connected to AC
power. The Back-UPS battery will charge while the Back-UPS is switched on or off
and is connected to AC power. Do not expect full battery run capability during the
initial charge time.
If the red Building Wiring FaultLED located on the side of the Back-UPS
illuminates, do not operate the Back-UPS. Have a qualified electrician correct the
building wiring fault.
Warranty
The standard warranty is two (2) years from the date of purchase. Schneider Electric
IT (SEIT) standard procedure is to replace the original unit with a factory
reconditioned unit. Customers who must have the original unit back due to the
assignment of asset tags and set depreciation schedules must declare such a need at
first contact with an SEIT Technical Support representative. SEIT will ship the
replacement unit once the defective unit has been received by the repair department,
or cross ship upon the receipt of a valid credit card number. The customer pays for
shipping the unit to SEIT. SEIT pays ground freight transportation costs to ship the
replacement unit to the customer.
Input
Voltage120 VacNominal
Frequency60 Hz +
3
Brownout Transfers92 Vac Typical
Over-voltage Transfer139 Vac Typical
Output
UPS Capacity
(4 battery backup outlets)
BE450G: 450 VA, 257 W;
BE550G: 550 VA, 330 W;
BE650G1: 650 VA, 390 W
Total Amperage (all outlets)12 A (including UPS output)
Voltage - On Battery115 Vac ± 8%
Frequency - On Battery60 Hz +
1
Transfer Time6 ms Typical, 10 ms maximum
Protection
and
Filtering
AC Surge ProtectionFull time, 340 Joules
EMI/RFI FilterFull time
AC InputResettable circuit breaker
Battery
TypeSealed, maintenance-free, lead acid
BE450G: RBC114
BE550G: RBC110
BE650G1: RBC17
Average Life3 - 5 years depending on the number of
discharge cycles and environmental
temperature
Physical
Net WeightReplacement battery cartridge
BE450G: 10 lb (4.7 kg)
BE550G: 12 lb (5.5 kg)
BE650G1: 14 lb (6.2 kg)
Dimensions
Length x Width x Height
12 in x 7 in x 3 in
30 cm x 18 cm x 9 cm
Operating Temperature32º F to 104º F (0º C to 40º C)
Storage Temperature5º F to 113º F (15º C to 45º C)
Operating Relative Humidity0 to 95% non-condensing humidity
Operating Elevation0 to 10,000 ft (0 to 3000 m)
EMI
Compliance
This device complies with part 68 and part 15 of the FCC rules.
Operation is subject to the following two conditions: (1) This device
may not cause harmful interference, and (2) This device must accept any
interference received, including interference that may cause undesired
operation.
Press the battery compartment cover
release tab located on the rear side of the
unit. Slide the battery cover off.
Connect the battery cable securely to the
battery terminal.
Reinstall the battery compartment cover.
Be sure that the release tab locks into place.
bu075c
Back-UP
S
bu064a
bu065a
bu066a
bu202a
Back-UPS
Battery Backup + Surge Protection
bu201b
CAUTION-Refer to bottom
of unit for safety markings.
Circuit
Breaker
Building
Wiring Fault
PowerChute
USB Port
Tel
Out
Push to
Reset
Tel
In
User Manual Back-UPS
BE 450G/550G/650G1