Introduction
Button functions
LCD Icon description
Technical specication
Product compliance
Safety Information
This product complies with the essential requirements and other relevant provisions of the following EU Directives:
EMC 2014/30/EU, LVD 2014/35/EU, RED 2014/53/EU and RoHS 2011/65/EU. Full text of the EU Declaration of
Conformity is available on www.salus-controls.com/uk
RT510+ / RT510TX+ / RT510RF+ is a programmable room thermostat used to control room temperature.
Device launching heating system by shorting terminal blocks, simultaneously informing the action and
showing this information on the LCD display. Extended features allows us to use various operating modes
- automatic (time schedules), manual, frost protection or holiday. Before use please read this manual
carefully. Use only AA 1.5 V alkaline batteries in the thermostat. Place the batteries into the battery slot
located under the cover. Do not use rechargeable batteries.
Use in accordance to national and EU regulations. Use the device as intended, keeping it in dry condition.
Product for indoor use only. Installation must be carried out by a qualied person in accordance to national
and EU regulations.
RT510+ / RT510TX+ Thermostat RXRT510+ Receiver
1
6 7
89
4
3
2 5
1. Boost function
2. Manual Mode
3. Frost protection / Holiday Mode
4. Increase button
5. Decrease button
6. When in Manual Mode,
ON will turn the boiler on.
7. When in Manual Mode,
OFF will turn the boiler o.
8. Receiver operates in automatic mode
according to the thermostat
9. Receiver output is controlled
by the On/O slide switch.
1. Day of the week
2. Program number
3. Program indicator
4. Settings
5. Temperature measured / set
6. Boost function
7. Low battery status
8. Wireless connection with the receiver
9. Heating Mode On
10. Manual Mode On
11. Holiday Mode On
12. Frost Protection Mode On
13. Temperature unit
14. AM / PM
15. Clock
RT510+ Thermostat RT510TX+ Thermostat
Thermostat supply 2 x AA alkaline batteries 2 x AA alkaline batteries
Thermostat rating max 3 (1) A -
Outputs Voltage free
NO / COM / NC terminals -
Temperature range 5 - 35°C 5 - 35°C
Temperature accuracy 0.1°C or 0.5°C 0.1°C or 0.5°C
Control algorithm ITLC / SPAN ITLC / SPAN
Radio frequency - 868 MHz
Dimension [mm] 120x96x27 120x96x27
RXRT510 Receiver
Receiver supply 230 V AC
Receiver rating max 16 (5) A
Outputs Voltage free NO / COM terminals
Radio frequency 868 MHz
Dimension [mm] 96x96x27
SALUS Controls plc
SALUS House
Dodworth Business Park South,
Whinby Road, Dodworth,
Barnsley S75 3SP, UK.
T: +44 (0) 1226 323961
E: sales@salus-tech.com
E: techsupport@salus-tech.com
SALUS Controls is a member of the
Computime Group.
Maintaining a policy of continuous product
development SALUS Controls plc reserve
the right to change speciïŹcation, design and
materials of products listed in this brochure
without prior notice.
RT510+, RT510TX+, RT510RF+
RT510TX+ & RT510RF (Thermostat) DIP Switch Settings
RT510+ Wiring diagram
L
N
M
COM
NO
NC
OR
MAX
3 (1) A
AC 230 V
RT510+
Thermostat
COM
NO
NC
RT510+
Thermostat
RT510TX+ Wiring diagram
Setting the time
Note: If you are using the RT510RF pack, the pairing between the thermostat and the receiver is already done.
RT510TX+
Thermostat
L
L
NO
N
N
COM
RXRT510+
Receiver
AC 230 V
RT510TX+
Thermostat
RXRT510
Receiver
COM
L
L
M
N
N
NO
OR
AC 230 V
MAX
16 (5) A
RT510+ Terminals description
RXRT510 Receiver terminals description
Terminal Description
1 - COM Common Terminal
2 - NC Switched Live OFF
3 - NO Switched Live ON
Terminal Description
NO Switch Terminal
COM Common Switch Terminal
L, N Supply (230 V AC)
T EST / PAIRING
SELECT SET
T EST / PAIRING
SELECT SET
T EST / PAIRING
SELECT SET
T EST / PAIRING
SELECT SET
T EST / PAIRING
SELECT SET
1
3
5
7
9
Press or to select the hour format.
Press the buttons SELECT and SET
together for 3 sec.
Press SELECT to conrm.
Press SELECT to conrm.
Press SELECT to conrm.
Press SET to conrm.
Press or to set the hour.
Press or to set the minutes.
Press or to set day of the week.
Thermostat will return to the main screen.
3 sec 3 sec
Programming - automatic mode
IRING
SELECT SET
IRING
SELECT SET
IRING
SELECT SET
IRING
T EST / PAIRING
SELECT SET
2
4
6
8
10
T EST / PAIRING
SELECT SET
T EST / PAIRING
SELECT SET
T EST / PAIRING
SELECT SET
T EST / PAIRING
SELECT SET
T EST / PAIRING
1
3
5
7
9
Use the or button to select day / days
from which you want to start programming.
Use the or button to set the hour
to start the program #1.
Use the or button to set the minutes
to start the program #1.
Use the or button
to set the temperature for program #1.
Follow steps 4-9,
to dene programs 2-6.
Press SET button to end programming.
Press the SET button to start programming.
Press SELECT to conrm.
Press SELECT to conrm.
Press SELECT to conrm.
Press SELECT to conrm.
In this mode, user can set the schedules for thermostat (temperature setpoints for specic periods of
time). To do this, rstly choose programming mode: “5-2” (business days + weekend) or “24h” (each
day separately) using parameter from . Programmed schedules should use all d04 Installer mode
time periods.
ON
1 2
ON
ELEC SPAN
RAD ITLC
The DIP Switches can be found on the rear of your thermostat.
For all plug-in boiler receiver applications ensure SW1 is set to RAD.
Control feature ITLC SPAN
Operation When ITLC is selected on DIP
switch № 2, the DIP switch №
1 is functional. You can choose
between radiator or electric
heater.
When Span is selected
on DIP switch № 2, the
DIP switch № 1 is not
functional.
2
3 5 64
1
15 14 1213
8
9
11
7
10
MON
TUE
WED
THU
FRI
SAT
SUN
MON M
TU
W
TH
FR
MON
TUE
WED
THU
FRI
M
TU
W
TH
FR
MON
TUE
WED
THU
FRI
MO
TU
WE
TH
FRI
MON
TUE
WED
THU
FRI
MON
TUE
WED
THU
FRI
THU
THU THU
MON
MON
MO
www.salus-tech.com
Issue Date: July 2019
V033
For PDF Installation guide please go to
www.salus-manuals.com
Quick
868.0-868.6MHz; <13dBm
PLUS
C
O
M
P
L
I
A
N
T
Internal Temperature
Load Compensation
RT510+ (Thermostat) Dip Switch Settings
The DIP Switches can be found on the rear of your thermostat.
ON
1 2
ON
NA SPAN
RAD ITLC
Control feature ITLC SPAN
Operation ITLC Internal Temperature
Load Compensation for
improved eciency.
When Span is selected
on DIP switch № 2, the
DIP switch № 1 is not
functional.
Temporary Override Mode
Hourly temperature Override Mode (+Hr)
RT510TX thermostat pairing with the receiver Installer Mode
Manual Mode and setting setpoint temperature
Frost Protection
Sleep mode
Holiday Mode
IRING
SELECT SET
T EST / PAIRING
SELECT SET
T EST / PAIRING
SELECT SET
RING
SELECT SET
T EST / PAIRING
SELECT SET
T EST / PAIRING
SELECT SET
T EST / PAIRING
T EST / PAIRING
T EST / PAIRING
IRING
T EST / PAIRING
SELECT SET
T EST / PAIRING
SELECT SET
T EST / PAIRING
SELECT SET
T EST / PAIRING
SELECT SET
2
4
T EST / PAIRING
SELECT SET
T EST / PAIRING
SELECT SET
T EST / PAIRING
SELECT SET
T EST / PAIRING
SELECT SET
T EST / PAIRING
SELECT SET
T EST / PAIRING
SELECT SET
RING
SELECT SET
RING
SELECT SET
T EST / PAIRING
T EST / PAIRING
SELECT SET
T EST / PAIRING
IR
SELECT SET
RING
SELECT SET
1
3
Using or button set a new setpoint
temperature for override.
Using or buttons set new setpoint
temperature.
Press three buttons at the same time
for 3 seconds.
Use or button to set the number
of days for Holiday Mode.
Using or buttons set new setpoint
temperature.
Press +Hr button to set number of hours for
temperature override (e.g. to set up override
for 3 hours, press the button 3 times).
Press the + Hr button until number of hours
disappears from display.
Press button to activate the Manual Mode.
Hold down button for 3 seconds
to activate the Holiday Mode.
Press button to turn On Frost
Protection mode.
Press button again to turn
O Frost Protection mode.
Press SET button
to conrm.
Press SET button to conrm.
You can set up to 31 days.
Using SELECT button choose the parameter.
Press SET to conrm.
Using or buttons set a parameter value.
Press any key to deactivate sleep mode. Thermostat will return to the previous mode.
Thermostat is in sleep mode.
After new setpoint temperature set,
thermostat will return to the main screen.
After new setpoint temperature set,
thermostat will return to the main screen.
This function is available only in automatic mode (schedule). If a new setpoint temperature will be set
during the schedule - it will be maintained until next time interval starts according to programmed
schedule.
In this mode thermostat does not work according to the programmed schedule but it will maintain
selected temperature.
In this mode the “frost protection” temperature is maintained for a specic number of days.
This function is available in Automatic and Manual Mode. It is used to change the setpoint temperature
for a specied number of hours (up to 9 hours). Once that time is over, thermostat returns to previous
mode.
Turning o hourly temperature override mode before time’s up
Turning O the Frost Protection Mode
Begin the pairing process
End the pairing process
Test the pairing process
Temporary Override mode will be disabled when new schedule will be set.
To turn o the Manual Mode press button. Once the manual mode is o, the hand icon on
the thermostat will disappear.
To turn o the Holiday Mode, hold down button for 3 seconds. The airplane icon should
disappear from the display.
Temperature of the Frost Protection mode is set as default at 5°C. This temperature can be changed
in Installer Mode in d03 parameter.
When the sleep mode is activated, all thermostat functions are paused.
If you bought the RT510TX+ and RXRT510+ separately or if you want to re-pair thermostat with the
receiver, make sure that the device is disconnected from the power supply and the switches on the
receiver have been set to AUTO and ON. Then connect the receiver to the power supply and wait for
the red LED to light steadily. Then switch to the OFF position and again to ON position quickly. The red
ashing LED will conrm entering the pairing mode.
2
2
4
4
1
1
3
3
3 sec
3 sec 3 sec
3 sec
Note: If you are using the RT510RF+ pack, the pairing between the thermostat and the receiver is already done.
dxx Function Parameter Default value
d01 Temperature display increments 0.1°C or 0.5°C 0.5°C
d02 Temperature oset +/- 3.0°C 0.0°C
d03 Frost Protection setpoint temperature 5.0°C - 17.0°C 5.0°C
d04 Programmer selection 5/2 or 24 hr (7d) 52d
T EST / PAIRING
SELECT SET
Press TEST / PAIRING button to check the
connection with the receiver.
ON
AUT O
OFF
MANUAL
1 sec
3 sec
3 sec
Hold and buttons simultaneously
for 3 seconds to start the sleep mode.
2
4
1
3
T EST / PAIRINGT EST / PAIRING
Press SELECT to conrm.
Follow steps 2-5, to set next parameters.
To exit the installer mode, wait 10 seconds
- thermostat will return automatically
to the main screen.
65
WED
WED
WED WED
WEDWED
WEDWED
SAT
Reset of the RT510+ thermostat
Press the RESET button once. You can use a paper
clip. Your thermostat will be reset and will start up
automatically.
RESET
SELECT SET
SAT
SAT
SAT
SAT SAT
T EST / PAIRING
SELECT SET
T EST / PAIRING
SELECT SET
(the pairing process takes up to 9 minutes)
Press and hold TEST/PAIRING button
for 3 seconds.
3 sec
THU
T EST / PAIRING
SELECT SET
T EST / PAIRING
SELECT SET
Once devices are successfully paired, LED on
the receiver will go solid red. Press and hold
TEST / PAIRING button for 3 seconds to end
the pairing process.
3 sec 3
THU
T EST / PAIRING
SELECT SET
Press TEST / PAIRING button again to
return to the main screen.
ON
AUT O
OFF
MANUAL
1 sec
THU
THUTHU
THUTHU
THU THU
THUTHU
Reset of the RT510TX+ thermostat
Remove the batteries without pressing any button.
Wait 2 minutes and insert the batteries again.
Your device will be restarted.
T EST / PAIRING
SELECT
+ −
+ −
SET
SAT
When you want to change the batteries your
device will use the internal memory to backup
your settings. You have 30 seconds to change the
batteries before losing your settings.
NOTE:
If you do not notice the “low battery” symbol displayed on the screen in time, it will shut down. In
this case, after removing the old batteries, it is necessary to wait 5 minutes before inserting the new
batteries. Otherwise, it is possible that a condenser will remain partially discharged and it can prevent
the thermostat from restarting.


Product specificaties

Merk: Salus
Categorie: Thermostaat
Model: RT510+

Heb je hulp nodig?

Als je hulp nodig hebt met Salus RT510+ stel dan hieronder een vraag en andere gebruikers zullen je antwoorden




Handleiding Thermostaat Salus

Handleiding Thermostaat

Nieuwste handleidingen voor Thermostaat