Revision: VCS-VCT-VPS-VPT-IOM (01-24) 1042552-F
GAS-FIRED LOW-INTENSITY TUBULAR RADIANT HEATER
INSTALLATION, OPERATION, AND MAINTENANCE
Supersedes: VCS-VCT-VPS-VPT-IOM (11-23) 1042552-E
MODELS VCS, VCT, VPS, AND VPT
⚠ DANGER ⚠
FIRE OR EXPLOSION HAZARD
•Failure to follow safety warnings exactly could result in serious injury, death, or property
damage.
•Improper installation, adjustment, alteration, service, or maintenance can cause serious injury,
death, or property damage.
•Installation and service must be performed by a qualified installer, service agency, or the
gas supplier.
•Be sure to read and understand the installation, operation, and service instructions in this
manual.
•Do not store or use gasoline or other flammable vapors and liquids in the vicinity of this or
any other appliance.
WHAT TO DO IF YOU SMELL GAS
•Do not try to light any appliance.
•Do not touch any electrical switch; do not use any phone in your building.
•Leave the building immediately.
•Immediately call your gas supplier from a phone remote from the building. Follow the gas
supplier’s instructions.
•If you cannot reach your gas supplier, call the fire department.
DO NOT DESTROY. PLEASE READ CAREFULLY. KEEP IN A SAFE PLACE FOR FUTURE REFERENCE.

2
VCS-VCT-VPS-VPT-IOM (01-24) 1042552-F
TABLE OF CONTENTS
GENERAL INFORMATION ...................................................................3
Important Safety Information.................................................................3
Warranty ................................................................................4
Model Application .........................................................................4
Certification..............................................................................4
Installation Codes .........................................................................4
Heater Location...........................................................................4
Hazards of Chlorine .....................................................................5
Mounting Height Requirements ............................................................5
Weights.................................................................................5
Dimensions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6
Clearances ..............................................................................6
SYSTEM CONFIGURATIONS.................................................................8
INSTALLATION...........................................................................16
Unpacking and Inspection..................................................................16
Pre-Installation Checklist...................................................................16
Heater Assembly.........................................................................17
Heater Suspension .......................................................................21
Vent Connections ........................................................................22
Vertical Venting .......................................................................23
Horizontal Venting .....................................................................24
Fresh Air Intake .......................................................................26
Piping Connections.......................................................................26
Gas Supply Pressure...................................................................26
Gas Supply Piping .....................................................................27
Supply Piping Connections ..............................................................28
Electrical Connections.....................................................................30
CONTROLS..............................................................................30
Pressure Switch .........................................................................30
Combination Gas Valve....................................................................30
Ignition Controller ........................................................................30
OPERATION .............................................................................31
Pre-Startup Checklist .....................................................................31
Startup.................................................................................31
Measure and Adjust Manifold Gas (Outlet) Pressure .............................................32
Post-Startup Checklist.....................................................................33
MAINTENANCE...........................................................................34
Service Checklist.........................................................................34
Maintenance Procedures ..................................................................35
Burner Maintenance....................................................................35
Fan and Motor Assembly Maintenance .....................................................36
Combination Gas Valve Maintenance ......................................................37
Ignition Controller Replacement...........................................................39
Pressure Switch Replacement............................................................39
TROUBLESHOOTING......................................................................40
General Troubleshooting...................................................................40
Troubleshooting Using Ignition Controller......................................................40
APPENDIX: MULTIPLE UNIT WIRING CONNECTIONS (MODELS VCT AND VPT).....................41
INSTALLATION RECORD (TO BE COMPLETED BY INSTALLER)..................................44

3
VCS-VCT-VPS-VPT-IOM (01-24) 1042552-F
GENERAL INFORMATION
•This heater has been tested for capacity and efficiency so as to provide many years of safe and dependable comfort
providing it is properly installed and maintained. With regular maintenance, this unit will operate satisfactorily year
after year. Abuse, improper use, and/or improper maintenance can shorten the life of the appliance and create
unsafe hazards.
•To achieve optimum performance and minimize equipment failure, it is recommended that periodic maintenance
be performed on this unit. The ability to properly perform maintenance on this equipment requires certain tools
and mechanical skills.
•This manual applies only to the models listed. Accessories referenced may not apply to all models.
Important Safety Information
Please read all information in this manual thoroughly and become familiar with the capabilities and use of your
appliance before attempting to operate or maintain this unit. Pay attention to all dangers, warnings, cautions, and
notes highlighted in this manual. Safety markings should not be ignored and are used frequently throughout to
designate a degree or level of seriousness.
DANGER: A danger statement describes a potentially hazardous situation that if not avoided, will result in severe
personal injury or death and/or property damage.
WARNING: A warning statement describes a potentially hazardous situation that if not avoided, can result in severe
personal injury and/or property damage.
CAUTION: A caution statement describes a potentially hazardous situation that if not avoided, can result in minor
or moderate personal injury and/or property damage.
NOTE: A note provides important information that should not be ignored.
⚠ WARNING ⚠
•Gas-fired appliances are not designed for use in hazardous atmospheres containing flammable
vapors or combustible dust, in atmospheres containing chlorinated or halogenated hydrocarbons,
or in applications with airborne silicone substances.
•Should overheating occur, or the gas supply control system fail to shut off the flow of gas, shut
off the manual gas valve to the unit before shutting off the electrical supply.
•Do not use this appliance if any part has been under water. Immediately call a qualified service
technician to inspect the appliance and replace any gas control that has been under water.
•Installation should be done by a qualified agency in accordance with these instructions. The
qualified service agency installing this heater is responsible for the installation.
•This appliance is not intended for use by persons with reduced physical, sensory, or mental
capabilities or lack of experience and knowledge, unless they have been given supervision or
instruction concerning use of the appliance by a person responsible for their safety.
•Children should be supervised to ensure that they do not play with the appliance.
⚠ CAUTION ⚠
•Never rest anything—especially a ladder—against the heater.
•To prevent damage to the unit or to its internal components, it is recommended that two wrenches
be used when loosening or tightening nuts. DO NOT OVERTIGHTEN!