Renzor ADF Handleiding


Pagina's 28 Niet gecategoriseerd

Bekijk de handleiding van Renzor ADF gratis online of download de PDF. Deze handleiding is 0 keer bekeken. Vraag over dit model? Stel een vraag

Form I-ADF, P/N 131805 R6, Page 1
Form I-ADF (12-15)
Obsoletes Form I-ADF (Version A.3)
Applies to: Indoor or Outdoor Gas, Direct-Fired,
Makeup Air/Heating Systems,
Model ADF and Model ADFH
Installation
Model ADF
!
WARNING:
FIRE OR EXPLOSION HAZARD
Failure to follow safety warnings exactly could result in serious injury, death, or
property damage.
Be sure to read and understand the installation, operation, and service instructions in
this manual.
Improper installation, adjustment, alteration, service, or maintenance can cause
serious injury, death, or property damage.
—Do not store or use gasoline or other ammable vapors and liquids in the vicinity
of this or any other appliance.
—WHAT TO DO IF YOU SMELL GAS
• Do not try to light any appliance.
• Do not touch any electrical switch; do not use any phone in your building.
• Leave the building immediately.
• Immediately call your gas supplier from a phone remote from the building. Follow
the gas supplier’s instructions.
• If you cannot reach your gas supplier, call the re department.
—Installation and service must be performed by a qualied installer, service agency,
or the gas supplier.

Form I-ADF, Page 2
WARNING: Improper installation, adjustment, alteration,
service, or maintenance can cause property damage,
injury or death. Read the installation, operation, and
maintenance instructions thoroughly before installing
or servicing this equipment.
WARNING: Gas-red appliances are not designed for
use in hazardous atmospheres containing ammable
vapors or combustible dust, or atmospheres containing
chlorinated or halogenated hydrocarbons. See Hazard
Levels above.
1.0 General
1.1 Hazard Labels and Notices
There are warning labels on the unit and throughout this manual. For your safety, read
the denitions below and comply with all boxes labeled CAUTION, WARNING, and
DANGER during installation, operation, maintenance and service of this heater.
HAZARD INTENSITY LEVELS
1. DANGER: Failure to comply will result in severe personal injury or
death and/or property damage.
2. WARNING: Failure to comply could result in severe personal injury or
death and/or property damage.
3. CAUTION: Failure to comply could result in minor personal injury and/
or property damage.
Hazard Intensity
Levels Apply to
Warnings throughout
this Manual
1.0 General .........................................................2
1.1 Hazard Labels and Notices .............................2
1.2 General Description ........................................3
1.3 Warranty ...........................................................3
1.4 Installation Codes ............................................3
2.0 Location .......................................................3
3.0 Uncrating and Preparation .........................4
3.1 Uncrating and Inspecting ................................4
3.2 Preparing for Installation ................................4
4.0. Clearances and Dimensions ....................4
4.1 Clearances to Combustibles ..........................4
4.2 Dimensions ......................................................4
5. Mounting .......................................................7
5.1 Weights .............................................................7
5.2 Rigging .............................................................7
5.3 Mounting on Field-Supplied Supports ..........7
5.4 Mounting on a Roof Curb ................................8
6.0 Mechanical ...................................................9
6.1 Gas Piping and Pressures ..............................9
6.2 Unit Inlet Air ...................................................11
6.3 Supply Air Discharge ....................................18
6.4 Blowers, Drives, and Blower Motors ...........19
7.0 Electrical and Wiring.................................19
7.1 General ...........................................................19
7.2 Supply Wiring .................................................19
7.3 Control Wiring ...............................................20
8.0 Controls .....................................................21
9.0 Commissioning and Startup ....................22
9.1 Checks Before Startup .................................22
9.2 Startup ............................................................24
9.3 Startup for Continuous Operation ...............26
Index .................................................................27
Additional References ....................................27
INSTALLATION RECORD ................................28
Table of Contents
Form I-ADF, P/N 131805 R6, Page 3
1.2 General
Description
The information in this manual applies to Model ADF and Model ADFH in Sizes 300,
500, 700 and 1200. Both Model ADF and ADFH are direct-red makeup air heating
systems. Model ADFH is designed with a high discharge air temperature.
These systems consist of a direct-red, gas-fueled burner and a draw-through blower
housed in a weatherized cabinet. The systems may be installed either indoors or out-
doors and are available for use with either natural or propane gas.
This direct-red makeup air system provides tempered makeup air. Makeup air
is dened as air that enters a building or area due to negative pressure created by
an air exhaust load in excess of the volume of entering air. This system warms the
outside air (or cools if equipped with an evaporative cooling module) and monitors
the volume and temperature of the makeup air added to the building. The system
may be used to provide ventilation in whole building or in spot applications. In whole
building applications, adding controlled makeup air will cause less inltration of dust
and dirt; will eliminate continuous backdraft in chimneys and vents; and will reduce
space heating fuel costs.
1.3 Warranty
Refer to the limited warranty information on the warranty form included in the "Owner's
Envelope".
1.4 Installation
Codes
These systems are design-certied to ANSI and CSA Standards. In order to retain
certication, the installer must adhere to the installation and operation requirements
in the instruction manual. These direct-red makeup air systems are not approved for
residential use.
Installation should be done by a qualied agency in accordance with the instructions
in this manual and in compliance with all codes and requirements of authorities having
jurisdiction. The qualied agency installing this system is responsible for the installation.
This direct-red makeup air system must be installed in accordance with local building
codes. In the absence of local codes, in the United States, the unit must be installed in
accordance with the National Fuel Gas Code (latest edition). A Canadian installation
must be in accordance with the CAN/CGA B149.1 and B149.2 Installation Code for Gas
Burning Appliances and Equipment. These codes are available from CSA Information
Services, 1-800-463-6727. Local authorities having jurisdiction should be consulted
before installation is made to verify local codes and installation procedure requirements.
Before installation, always consult authorities having local jurisdiction to verify that
local codes and procedures are being followed.
The building should always provide adequate relief for the heater to operate at its
rated capacity. It should be noted that this can be accomplished by taking into account,
through standard engineering methods, the structure's designed inltration rate; by
providing properly sized relief openings; by interlocking a powered exhaust system;
or by a combination of these methods. Insufcient ventilation air which results in
inadequate dilution of the combustion products generated by the heater may create
hazardous concentrations of carbon dioxide, carbon monoxide, nitrogen dioxide, and
other combustion products into the heated space.
If the failure or malfunction of this heater creates a hazard to other fuel burning equip-
ment in the building, interlock the system to open inlet dampers or other such devices.
Codes for Special Installations: (1) Aircraft Hangar -- Installation in an aircraft hangar
must be in accordance with the Standard for Aircraft Hangars, ANSI/NFPA 409 (latest
edition) or CAN/CGA B149 Installation Codes; (2) Public Garage -- Installation in a
public garage must be in accordance with the Standard for Parking Structures, ANSI/
NFPA 88A (latest edition) or the Standard for Repair Garages, ANSI/NFPA 88B (latest
edition) or in Canada with CAN/CGA B149 Installation Codes.
2.0 Location
Location must comply with clearances in Paragraph 4.1. Makeup air should enter at
the highest point practical. By doing this, the fresh air will entrain dust laden air at the
ceiling and move it toward the point of exhaust. Also, fresh air directed downward from
the roof or ceiling will mix with hot ceiling air resulting in improved distribution of heat
in the building.
Always introduce fresh makeup air so that it moves across the greatest distance within
the room or building before reaching an exhauster.

Beoordeel deze handleiding


Product specificaties

Merk: Renzor
Categorie: Niet gecategoriseerd
Model: ADF

Heb je hulp nodig?

Als je hulp nodig hebt met Renzor ADF stel dan hieronder een vraag en andere gebruikers zullen je antwoorden