Rane SSA 6 Handleiding
Rane
Niet gecategoriseerd
SSA 6
Bekijk gratis de handleiding van Rane SSA 6 (6 pagina’s), behorend tot de categorie Niet gecategoriseerd. Deze gids werd als nuttig beoordeeld door 4 mensen en kreeg gemiddeld 4.6 sterren uit 2.5 reviews. Heb je een vraag over Rane SSA 6 of wil je andere gebruikers van dit product iets vragen? Stel een vraag
Pagina 1/6

Manual-1
OPERATORS MANUAL
SSA 6
MULTICHANNEL AMPLIFIER
QUICK START
You gots your good habits, and you gots your bad habits. A good habit is to read at least this much of the manual. A bad
habit is not to read any of this manual. Reading just this section can prevent grief worse than your worst nightmare. Grief
that's hard to get rid of—harder than a bad habit.
Be sure the amplifier is off before making any connections. Euroblock speaker connectors make connecting the ampli-
fier easy. They are just like little snap-on terminal blocks that take up to 12 gauge wire. Gold plated RCA connectors take
standard unbalanced sources. See Rane Note 110 for more information about other connectors. Keep your input cable
lengths as short as possible. Speaker loads should be no less than four ohms per output. If you are running multiple speak-
ers per Channel in series or parallel, check your final impedances.
If you are running six separate Channels (unbridged), be sure all the BRIDGED switches on the rear panel are de-
pressed. If you are running any Channels bridged, you are obviously a power user and we highly recommend you read
further into the manual regarding this issue.
With Input and Output connections completed, be sure all front panel LEVEL controls are all the way counterclock-
wise. Now flip the POWER switch and after hearing the relays click in after a second, notice that the READY lights come
on. Slowly turn up each Channel's LEVEL control to the desired gain and if all is well you should hear something pleasant.
If not, re-check connections, put on a better CD, and read more of the manual.

Manual-2
FRONT PANEL DESCRIPTION
1. POWER switch: Obediently turns the SSA 6 on and off every time you poke it with your finger (or other suitable object).
All six Channels have delayed turn-on/instant turn-off relays to eliminate any switching transients.
2. THERMAL overload indicator: This red LED lights up if the SSA 6 becomes too hot, indicating that power has been
removed from all six Channels. Be sure to check the fan filter and actual speaker impedances if this lights up.
3. POWER indicator: This magnificent blue LED lights whenever the SSA 6 POWER switch is turned on.
4. READY indicators: Each of these green LEDs light whenever the mute relay is passing the signal through to the speaker.
Normal operation is the on status.
5. LOAD LIMIT indicators: Each of these red LEDs lights whenever a Channel leaves the Safe Operating Area (SOA). This
means the amplifier turned down the Input level quickly and automatically, avoiding over-dissipation. Input signals 30 dB
over a safe limit will cause the READY indicator and mute relay to turn off until the amplifier has been turned off and the
problem corrected. Normal operation is the off status.
6. PEAK LIMIT indicators: These red LEDs light whenever a Channel’s Output cannot follow its Input. The amplifier has
turned down the Input level quickly and automatically, avoiding audible distortion. Normal operation is the off status.
7. Channel LEVEL controls: Each of these rotary controls determines the Input sensitivity of each respective Amplifier
Channel. At its full clockwise position, an Input signal of 0 dBu (.775 vrms) drives the Amplifier to full power. As the
controls are rotated counterclockwise, more Input signal level will be needed to achieve full power.

Manual-3
REAR PANEL DESCRIPTION
1. INPUTS: These are standard unbalanced RCA connectors. For balanced sources consult Rane Note 110.
2. NORMAL/BRIDGED switches: With the switch in the out position and the LED indicator the SSA 6 is operating inon,
BRIDGED mode. The SSA 6 utilizes the BRIDGE switch to make internal connections between each pair of Channels: 1&2,
3&4, and 5&6. Whenever a signal is connected to an odd numbered Channel (say channel 1), the next even-numbered
Channel is driven inverted when the BRIDGE switch is activated. When the BRIDGE switch is inactive, the internal
connection is defeated and both Channels operate independently. Inputs should be connected to Odd Amplifier Channels
only (1,3,5), and speakers connected to the “+” terminals of each Channel pair as shown on the SSA 6 chassis silk-screen.
3. OUTPUTS: Connect the speaker(s) to each of the six Channels by means of the Euroblock connectors with 18 to 12 AWG
wire (See #2 for Bridged operation).
4. AC line cord: Plug this into a grounded AC outlet of l20VAC (or 240VAC if the SSA 6 is internally wired for 240V
operation). NOTE: If you use an adapter to plug the SSA 6 into a non-grounded outlet (three-to-two prong adapter), be sure
to screw the ground adapter to the outlet by means of the cover plate screw.
5. Line fuse: Use only a 15 amp 250 volt Fast-blow (or Normal blow—not Slow blow) fuse, 1.25" long, such as Buss ABC-15
(120 volt) or equivalent. For 240 volt use Buss ABC-8 or equivalent.
6. Fan filter: This washable filter may easily be removed for periodic cleaning by gently pulling on the black plastic housing
and then lifting it away–perform this feat with the fan off, of course. Once the filter is removed, rinse it under hot tap water;
and use dish soap to cut through particularly stubborn pollution deposits.
IMPORTANT: Keep this filter clean to ensure proper cooling and reliability of the SSA 6. Never remove the filter with the
unit plugged in.
The SSA 6 draws a tremendous amount of air to ensure proper cooling and resultant long term reliability. Check and clean
the filter as often as necessary, especially if the thermal overload indicator ever comes on.
Product specificaties
Merk: | Rane |
Categorie: | Niet gecategoriseerd |
Model: | SSA 6 |
Heb je hulp nodig?
Als je hulp nodig hebt met Rane SSA 6 stel dan hieronder een vraag en andere gebruikers zullen je antwoorden
Handleiding Niet gecategoriseerd Rane
17 Juni 2025
17 Juni 2025
17 Juni 2025
17 Juni 2025
17 Juni 2025
17 Juni 2025
17 Juni 2025
17 Juni 2025
17 Juni 2025
17 Juni 2025
Handleiding Niet gecategoriseerd
- Brondi
- Osram
- Heidemann
- ECTIVE
- Chantal
- Emmaljunga
- Vertex
- JOBY
- Nesco
- PAG
- Irradio BelAir
- ALC
- Flo
- RAM Mounts
- Mobli
Nieuwste handleidingen voor Niet gecategoriseerd
18 Juni 2025
18 Juni 2025
18 Juni 2025
18 Juni 2025
18 Juni 2025
18 Juni 2025
18 Juni 2025
18 Juni 2025
17 Juni 2025
17 Juni 2025