Bekijk gratis de handleiding van Rain Bird 500 (2 pagina’s), behorend tot de categorie Niet gecategoriseerd. Deze gids werd als nuttig beoordeeld door 276 mensen en kreeg gemiddeld 4.4 sterren uit 138.5 reviews. Heb je een vraag over Rain Bird 500 of wil je andere gebruikers van dit product iets vragen? Stel een vraag

Pagina 1/2
Rain Bir 500 Series
SPECIFICATIONS
Radius:
28' to 47' (8.5 m to 14.3 m)
Flow Rate:
7.25 to 13.20 gpm (1.65 to 3.00 m/h)
Arc:
Full-circle 360°
Models:
Full-Circle:
500E: Electric
500IC: Integrated Control
Stopamatic (SAM) 500S/H: Combined use
or Hydraulic (N.O.)*
500B: Seal-A-Matic™ device
Maximum Inlet Pressure:
Models 500E and IC: 150 psi (10.3 bars)
Models 500S/H and B: 100 psi (6.9 bars)
Pressure Regulation Range: 60 to 100 psi
(4.1 to 6.9 bars)
Factory Pressure Settings: 500E/IC available in 70
and 80 psi (4.8 and 5.5 bars)
Inlet Threads:
Models E, IC, S/H: 1.25" (3.2 cm) ACME
Female Threaded
Models B: 1" (2.5 cm) ACME Female Threaded
Dimensions:
Body Height:
Models E, IC, S/H: 12.0" (30.5 cm)
Models B: 9.6" (24.5 cm)
Pop-Up Height to Mid-Nozzle:
Models E, IC, S/H, B: 2.6" (6.6 cm)
Top Diameter:
Models E, IC, S/H: 6.25" (15.9 cm)
Models B: 4.25" (10.8 cm)
Rotation Time:
360° in ≤ 180 seconds; 150 seconds nominally
Holdback:
Block: 10' (3.1 m) of elevation
SAM/Hydraulic: 15' (4.6 m) of elevation
Nozzle Trajectory:
51 Nozzle: 12°
52, 53, 54 Nozzles: 25°
Maximum Stream Height:
51 Nozzle: 5' (1.5 m)
52, 53, 54 Nozzles: 13' (4.0 m)
Solenoid: 24 VAC solenoid power requirement:
0.41 amp inrush current (9.8 VA);
60 cycle: 0.25 amp holding current (6.0 VA);
50 cycle: 0.32 amp holding current (7.7 VA)
Surge Resistance: Up to 25kV standard on
electric models
Top-Serviceable Rock Screen
and Replaceable Valve Seat:
On models 500E, IC, S/H
* N.O. — Normally open
500 Series
A 500 X XX XX
Model
500 Body/
Valve
E
IC
SH
B
Thread
Type
ACME
HOW TO SPEC IF Y
Pressure
Regulator
70 (4.8)
80 (5.5)
Nozzle
51
52
53
54
Gear-Driven Rotors
Rain Bir 500 Series Rotors
Metric Data
Base Pressure
(bars)
4.1 4.8 5.5 6.2 6.9
Radius Radius Radius Radius RadiusFlow Flow Flow Flow Flow
(m) (m3/h) (m) (m3/h) (m) (m3/h) (m) (m3/h) (m) (m3/h)
#51-Blue 8.5 1.65 1.87 1.91 1.959.1 1.78 9.4 9.8 9.8
#52-Beige 10.7 10.7 10.71.64 1.75 1.88 1.9811.3 11.3 2.07
#53-Gray 13.1 2.13 13.7 13.7 13.7 13.72.29 2.45 2.48 2.54
#54-Red 14.3 14.3 14.3 14.3 14.32.54 2.73 2.91 2.95 3.00
Performance Data: 500 Series
U.S. Data
Base Pressure (psi)
60 70 80 90 100
Radius Radius Radius Radius RadiusFlow Flow Flow Flow Flow
(ft) (ft) (ft) (ft) (ft)(gpm) (gpm) (gpm) (gpm) (gpm)
#51-Blue 32 8.42 3228 7.25 7.8530 31 8.25 8.60
#52-Beige 35 35 357.20 7.70 8.30 37 378.70 9.10
#53-Gray 43 9.40 45 45 45 4510.10 10.80 10.90 11.20
#54-Red 47 47 47 47 4711.20 12.00 12.80 13.00 13.20
All data is generated from tests conducted in accordance with ASAE Standard S398.1 for at least 30 minutes in zero-wind conditions. Rain Bird recommends the
use of SPACE for Windows,® equivalent program or derived performance data to optimize nozzle selection.
Gear-Driven Rotors
Rain Bir 500 Series Rotors www.rainbird.com


Product specificaties

Merk: Rain Bird
Categorie: Niet gecategoriseerd
Model: 500

Heb je hulp nodig?

Als je hulp nodig hebt met Rain Bird 500 stel dan hieronder een vraag en andere gebruikers zullen je antwoorden