Bekijk gratis de handleiding van Projecta VSR100 (2 pagina’s), behorend tot de categorie Niet gecategoriseerd. Deze gids werd als nuttig beoordeeld door 19 mensen en kreeg gemiddeld 4.4 sterren uit 9 reviews. Heb je een vraag over Projecta VSR100 of wil je andere gebruikers van dit product iets vragen? Stel een vraag

Pagina 1/2
FEATURES
Projecta’s Voltage Sensitive Relays (VSRs) are suitable for
a wide variety of 12V DC applications.
VSRs sense the input voltage and automatically connect/
disconnect the appliance or circuit at the set voltages.
The cut-out has an 8 sec. delay preventing the relay from
disconnecting during a momentary drop in voltage.
Manual override
Manual override is activated by connecting the override
wire to 12V DC. This bypasses the automatic voltage sensor
allowing the relay to be engaged below the set voltages.
Surge protected
Weatherproof (IP66)
L.E.D Indicator (on/contact closed)
WARNING
PLEASE READ THESE INSTRUCTIONS COMPLETELY
PRIOR TO INSTALLATION.
BATTERIES PRODUCE EXPLOSIVE GASES –
Ensure no sparks or flames are present.
Wear eye protection.
Vehicles must be in NEUTRAL or ‘PARK’,
park brakes ‘ON’.
Follow all vehicle manufacturer’s instructions.
Beware of moving parts.
Voltage Sensitive Relays (VSR) are designed for negative
ground alternator systems with batteries of the same
nominal voltage.
Batteries of differing voltages cannot be used.
SPECIFICATIONS
P/No.VSR100 VSR200
VOLTAGE 12V12V
CHARGING CURRENT100A Continuous, 200A Peak200A Continuous, 400A Peak
CUT-IN VOLTAGE13.4V13.4V
CUT-OUT VOLTAGE12.8V12.8V
CUT-OUT DELAY8 sec.8 sec.
CHARGE TYPEParallelParallel
CONTROL MCUMCU
MOUNTINGSurface/Firewall Surface/Firewall
CURRENT DRAWCharging 550mA (standby 10mA)Charging 680mA (standby 10mA)
VOLTAGE DROPNilNil
SURGE PROTECTIONBuilt-inBuilt-in
ENVIRONMENTAL PROTECTIONIP66IP66
OVERRIDERequires minimum 10VRequires minimum 10V
RECOMMENDED FUSE150A250A
MINIMUM CABLE SIZE14mm2(6 B&S)32mm2(2 B&S)
TORQUE SETTINGS3.75Lb/ft, 5Nm3.75Lb/ft, 5Nm
Distributed byAUSTRALIA
Brown & Watson International Pty Ltd
Knoxfield, Victoria 3180
Telephone(03) 9730 6000
Facsimile(03) 9730 6050
National Toll Free1800 113 443
NEW ZEALAND
Narva New Zealand Ltd
22–24 Olive Road
PO Box 12556 Penrose
Auckland, New Zealand
Telephone(09) 525 4575
Facsimile(09) 579 1192
IS115
Issue 2: 19.7.10