Powerplus POWXG9540 Handleiding

Powerplus Pomp POWXG9540

Lees hieronder de 📖 handleiding in het Nederlandse voor Powerplus POWXG9540 (8 pagina's) in de categorie Pomp. Deze handleiding was nuttig voor 33 personen en werd door 2 gebruikers gemiddeld met 4.5 sterren beoordeeld

Pagina 1/8
POWXG9540 EN
Copyright © VARO NV 2022 P a g e | 1www.varo.com
1 APPLICATION .................................................................................. 2
2 DESCRIPTION (FIG A) .................................................................... 2
3 PACKAGE CONTENT LIST ............................................................. 2
4 SYMBOLS ........................................................................................ 2
5 GENERAL POWER TOOL SAFETY WARNINGS .......................... 3
6 BEFORE START-UP, NOTE THE FOLLOWING! ........................... 3
7 INSTALLATION ................................................................................ 3
8 MAINS SUPPLY ............................................................................... 4
9 COMMISSIONING ............................................................................ 4
10 SERVICING! ..................................................................................... 4
11 CLEANING THE TURBINE .............................................................. 4
12 SETTING THE SWITCH POINT ....................................................... 4
13 ANOMALIES SOURCES REMEDIES 5– – .......................................
14 TECHNICAL DATA .......................................................................... 6
15 SERVICE DEPARTMENT ................................................................ 6
16 STORAGE ........................................................................................ 6
17 WARRANTY ..................................................................................... 7
18 ENVIRONMENT ............................................................................... 7
19 DECLARATION OF CONFORMITY ................................................ 8
POWXG9540 EN
Copyright © VARO NV 2022 P a g e | 2www.varo.com
MULTI-STAGE SUBMERSIBLE PUMP 750W
POWXG9540
1 APPLICATION
This pump is used primarily as cellar pump. When installed in a shaft, the pump provides
protection from flooding. It is also used wherever water has to be moved from one place to
another, e.g. in the home, agriculture, horticulture, plumbing and many other applications.
Not suitable for professional use.
WARNING! Read this manual and general safety instructions carefully
before using the appliance, for your own safety. Your power tool should
only be passed on together with these instructions.
2 DESCRIPTION (FIG A)
1. motor housing
2. water inlet
3. water outlet
4. cable & plug
5. floating switch
6. carrying handle
3 PACKAGE CONTENT LIST
â–ª Remove all packing materials
â–ª Remove remaining packaging and transit supports (if existing)
â–ª Check the completeness of the packing content
â–ª Check the appliance, the power cord, the power plug and all accessories for transportation
damages.
â–ª Keep the packaging materials as far as possible till the end of the warranty period.
Dispose it into your local waste disposal system afterwards.
WARNING Packing materials are no toys! Children must not play with
plastic bags! Danger of suffocation!
1x pump
1x Manual
1x connector
When parts are missing or damaged,
please contact your dealer.
4 SYMBOLS
In this manual and/or on the machine the following symbols are used:
Denotes risk of personal
injury or damage to the tool.
Read manual before use
POWXG9540 EN
Copyright © VARO NV 2022 P a g e | 3www.varo.com
5 GENERAL POWER TOOL SAFETY WARNINGS
Read all safety warnings and all instructions. Failure to follow all warnings and instructions
may result in electric shock, fire and/or serious injury. Save all warnings and instructions for
future reference. The term "power tool" in the warnings refers to your mains operated (corded)
power tool or battery operated (cordless) power tool.
6 BEFORE START-UP, NOTE THE FOLLOWING!
â–ª The pump can be connected to any shock-proof plug which has been installed according
to regulations. The plug must have a supply voltage of 230 V ~ 50 Hz. Fuse min. 6 Amp.
Caution!
When the pump is to be used near swimming pools or garden ponds and in their area of
protection, it must be equipped with a PRCD (residual current circuit breaker) with a nominal
trip current of max. 30 mA (according to VDE 0100, part 702 and 738). The pump must not be
operated while people are in the swimming pool or in the garden pond! Please contact your
electrician!
Attention!
(Important for your own security) Before starting to run your new submersible pump, please
have the following items checked by an expert:
â–ª Ground connection
â–ª Zero conductor
â–ª Fault current breaker switch must correspond the safety regulations of the power plants
and they must work faultlessly.
â–ª The electrical connections must be protected from moisture.
â–ª If there is danger of flooding, the electrical connections must be taken to higher ground.
â–ª Circulation of aggress e fluids, as well as the circulation of abrasive materials must be iv
avoided at all costs.
â–ª The submersible motor-driven pump must be protected from frost.
â–ª The pump must be protected from running dry.
â–ª Access on the part of children should also be prevented with appropriate measures.
Consistency
Your submersible pump is designed for the circulation of water with a maximum temperature
of 35° C. This pump may not be used for other fluids, especially motor fuels, cleaning fluids,
and other chemical products!
7 INSTALLATION
This pump is designed for exclusively domestic installation:
â–ª In places where there is a risk of flooding.
â–ª In sumps or wells.
Keep an empty space around the pump so that the float switch can work without being
blocked (e.g. use a sump at least 40x40x50 cm).
The pump is designed to run in liquid not exceeding 35 °C.
It can be installed:
â–ª With either a fixed conduit.
â–ª Or a flexible conduit.
It must be fixed by the handle provided for the purpose or set at the bottom of the sump (it
must be clean with no impurities or sludge)
If water level is low (long period of drought), be careful to ensure that any impurities or sludge,
after drying, do not prevent the pump from starting up. Consequently, you must make sure that
the site where the pump is installed is clean and run the pump from time to time.
The pump must always be used in the upright position (the handle on top), it is recommended
to secure the pump by attaching a rope (or similar item) to the handle and the other end to an
easy accessible static object.


Product specificaties

Merk: Powerplus
Categorie: Pomp
Model: POWXG9540

Heb je hulp nodig?

Als je hulp nodig hebt met Powerplus POWXG9540 stel dan hieronder een vraag en andere gebruikers zullen je antwoorden




Handleiding Pomp Powerplus

Handleiding Pomp

Nieuwste handleidingen voor Pomp