Bekijk gratis de handleiding van Planet MC-700 (4 pagina’s), behorend tot de categorie Niet gecategoriseerd. Deze gids werd als nuttig beoordeeld door 349 mensen en kreeg gemiddeld 5.0 sterren uit 175 reviews. Heb je een vraag over Planet MC-700 of wil je andere gebruikers van dit product iets vragen? Stel een vraag

Pagina 1/4
- 1 -
- 2 -
- 3 -
- 4 -
- 5 -
- 6 -
- 7 -
- 8 -
1. Package Contents
Before start installing the Converter, verify the package
contains the following parts:
● TheMediaConverterChassisx1
● User'sManualx1
● MountingAccessory(for10/19”ChassisShelf)x1
● RubberFeetx4
● ACPowerCordx1
Ifanyofthesearemissingordamaged,pleasecontactyour
dealer immediately, if possible, retain the carton including
the original packing material, and use them against to
repacktheproductincasethereisaneedtoreturnittous
for repair.
3. Media Converter Chassis Front
Panel
Figure 3-1 & 3-2 & 3-3 shows a front panel of MC-700 /
MC-1500/MC-1500R/MC-1500R48.
Figure 3-1 MC-700 front panel
Figure 3-2 MC-1500 front panel
Figure 3-3 MC-1500R / 1500R48 front panel
The rear panel of the MC-1500R / 1500R48 is with two
powermoduleslotsforredundantpowersupport.
Figure 5-3 MC-1500R / 1500R48 Rear panel
Note
1.TheMC-1500Rshippedwithone100~240V
ACpowersupplymodule(MC-15RPS90).
2.TheMC-1500R48shippedwithoneDC-
48Vpowersupplymodule(MC-15RPS48).
Power
Notice
1.Thedeviceisapower-requireddevice,it
means,itwillnotworktillitispowered.
Ifyournetworksshouldactiveallthe
time,pleaseconsideruseaproperUPS
(UninterruptedPowerSupply)foryour
device.Itwillpreventyoufromnetwork
datalossornetworkdowntime.
2.Insomearea,installingasurge
suppressiondevicemayalsohelpto
protectyourchassisfrombeingdamaged
byunregulatedsurgeorcurrenttothe
converterorthepoweradapter.
MC-1500R /1500R48
Printing LED
Status Description
PWR1
ON
ThechassisispoweredbyACpower
source(MC-15RPS90)orDCpower
source(MC-15RPS48).
OFF Thechassisisnotpoweredorpower
failure.
PWR2
ON
ThechassisispoweredbyACpower
source(MC-15RPS90)orDCpower
source(MC-15RPS48).
OFF Thechassisisnotpoweredorpower
failure.
FANA/
FANB
ON ThefanisfunctionalO.K
OFF
Thefanisnotpoweredoritis
malfunction.IfthefanLEDremains
offwhilepowerison.Pleaseconsult
yourlocaldealertoreplacetheFAN.
2. Product Features
● Highquality10"/19”Rack-MountableChassisinstallation
● Supports up to seven (7) / fteen (15) hot-swappable
mediaconverters
● One fan brings the air-ow for system cooling, and LED
indicatorsforsystemandfanstatus(MC-700)
● Two fan brings the air-ow for system cooling, and LED
indicators forsystemandfanstatus (MC-1500/1500R /
1500R48)
● Two power slots at rear panel for redundant power
support with options of 100~240V AC or -48V DC
supplies(MC-1500R/1500R48)
● Bay power isolation, ensure each bay is electrically
isolatedfromeachother
● Supportmultiple converterswith10/100/1000Mbps,
copper,Fiber,single/multi-modeST/SC/SFPconnectors
● Reducetheeffortofconvertermaintenanceandmanage-
ment,diagnosethestatusatonetime
● Cost-effective,easyinstall
4. LED Indicators
MC-700
Printing LED
Status Description
PWR
ON Thechassisispowered.
OFF
Thechassisisnotpoweredorpower
failure,iftheACoutletiswith
100~240VACvoltage.Pleaseconsult
yourlocaldealerifpowerfailure.
FAN
ON Thefanisfunctionalok.
OFF
Thefanisnotpoweredoritis
malfunction.IfthefanLEDremains
offwhilepowerison.Pleaseconsult
yourlocaldealertoreplacetheFAN.
MC-1500
Printing LED
Status Description
PWR
ON Thechassisispowered.
OFF
Thechassisisnotpoweredorpower
failure,iftheACoutletiswith
100~240VACvoltage.Pleaseconsult
yourlocaldealerifpowerfailure.
FANA/
FANB
ON ThefanisfunctionalO.K.
OFF
Thefanisnotpoweredoritis
malfunction.IfthefanLEDremains
offwhilepowerison.Pleaseconsult
yourlocaldealertoreplacetheFAN.
5. Media Converter Chassis Rear
Panel
Figure 5-1 & 5-2 & 5-3 shows a front panel of MC-700 /
MC-1500/MC-1500R/MC-1500R48.
The rear panel of the MC-700 is with one fan, one ON/
OFF Switch and a power inlet that accept 100~240V AC,
50/60Hzpowerinput.
Figure 5-1 MC-700 Rear panel
The rear panel of the MC-1500 is with two fans, one ON/
OFF Switch and a power inlet that accept 100~240V AC,
50/60Hzpowerinput.
Figure 5-2 MC-1500 Rear panel
6. Installing the Media Converter
Chassis
6.1 Installing Media Converter Chassis to
10/19-inch Wiring Closet Rack
» Installfourscrewsthroughmountingearsintoeachside.
» Locate Converter Chassis at 10/19-inch mounting rails
andscrewupthefrontbrackets.
» Set Main power switch at “OFF” position before
connectingthepowercord.
Figure 6-1 InstallingMediaChassisinWiringClosetRails
- 9 -
- 10 -
- 11 -
- 12 - - 13 - - 14 -
6.2 Installing Converters to the Media
Converter Chassis
» TurnofftheConverterChassispower.
» Verify the Media Converter is right for this Chassis and
locate +5VDC power jack on converter back, carefully
slide in and plug to match 10”/19” Chassis slot +5V
DC receptacle. Push up the picket fence to lock the
converters.
Note
The slide-in Media Converters and Converter
Chassisshouldbesuppliedonlyfrom PLANET,
both Media Converters and Chassis are built
to match eachother atdimensions,DCpower
jack,andDCreceptacleandpowersafety.
» Ensurethatthereisnoactivityinthenetwork.
» Connectthemediacablefornetworkconnection.
» Turnonthechassis power,thePowerLED,andbothFAN
LEDindicatorswilllightup.
7. Product Specications
MC-700 Converter Chassis Specications
Dimension 217mmx88.5mmx140mm(Wx
HxD),2Uheight
Converter Slots 7slots
Power Input 100~240VAC,50/60Hz
Power
Consumption 40Wattsmaximum/136BTU
Power Output
Per Slot +5VDC
DC Plug Per Slot 2.5mmDCreceptacle
LED Indication 2;Power,FAN
FAN 1
Temperature /
Humidity
Operating Environment
0~50DegreeC;Humidity:5~90%
non-condensing
Storage Environment
-40~70DegreeC;Humidity:5~90%
non-condensing
Emission FCCPart15ClassA,CE
6.3 Converter Check Point
Fiber
Port
Attachtheber
cable.TheTx,
Rxbercable
mustbepaired
atbothends.
2.5mm
DCReceptacle2.5mm
+5Vforeachslot
TP
Port
Attach UTP
Cat. 3 or 5 ca-
ble to TP port.
DCreceptacleis2.5mmwide
thatconformstoandmatches
theMediaConverter2.5mmDC
jack'scentralpole.Donotinstall
anyimproperunit,modelofthe
MediaConverter.
Note
For safety reason, it is recommended storing
the AC adapter of the converter in a known
securedplace.Formoreaboutconverter,refer
totheuserguideoftheconverter.
MC-1500 Converter Chassis Specications
Dimension 440mmx103mmx180mm(Wx
HxD),2.4Uheight
Converter Slots 15slots
Power Input 100~240VAC,50/60Hz
Power
Consumption 70Wattsmaximum/238BTU
Power Output
Per Slot +5VDC
DC Plug Per Slot 2.5mmDCreceptacle
LED Indication 3;Power1,FANA,FANB
FAN 2
Temperature /
Humidity
Operating Environment
0~50DegreeC;Humidity:5~90%
non-condensing
Storage Environment
-40~70DegreeC;Humidity:5~90%
non-condensing
Emission FCCPart15ClassA,CE
MC-1500R / MC-1500R48 Converter Chassis
Specications
Model MC-1500R MC-1500R48
Dimension 440mmx103mmx180mm(WxH
xD),2.4Uheight
Converter Slots 15slots
Power Input 100~240VAC,
1.5A,50-60Hz
DC-48V,2A,
Range:-30V~-60V
Power
Consumption
8.4Watts/28BTU
(1xpowersupply,
notinclude
converters)
80Watts/272BTU
(Fullloading)
5.3Watts/18BTU
(1xpowersupply,
notinclude
converters)
80Watts/272BTU
(Fullloading)
Power Output
Per Slot +5VDC
DC Plug Per
Slot 2.5mmDCreceptacle
LED Indication 4;Power1,Power2,FANA,FANB
FAN 2
Temperature /
Humidity
Operating Environment
0~50DegreeC;Humidity:5~90%
non-condensing
Storage Environment
-40~70DegreeC;Humidity:5~90%
non-condensing
Emission FCCPart15ClassA,CE
8. Customer Support
Thank you for purchase PLANET products. You can browse
our online FAQ resource at the PLANET Web site rst to
checkifitcouldsolve you issue.Ifyouneed more support
information,pleasecontactPLANETMediaConvertersupport
team.
PLANETonlineFAQ:
http://www.planet.com.tw/en/support/faq.php?type=3
MediaConvertersupportteammailaddress:
support_converter@planet.com.tw
Copyright©PLANETTechnologyCorp.2009.
Contentssubjecttorevisionwithoutpriornotice.
PLANET is a registered trademark of PLANET Technology
Corp. All other trademarks belong to their respective
owners.


Product specificaties

Merk: Planet
Categorie: Niet gecategoriseerd
Model: MC-700
Kleur van het product: Zwart
Breedte: 217 mm
Diepte: 140 mm
Hoogte: 88.5 mm
LED-indicatoren: Ja
Aantal sloten: 7
Plug and play: Ja
Temperatuur bij opslag: -40 - 70 °C
Aantal ventilatoren: 1 ventilator(en)
Luchtvochtigheid bij opslag: 5 - 90 procent
Rack-montage: Ja
AC-adapter, uitgangsspanning: 5 V
Veiligheid: FCC, CE
Maat: 10 "
Rackcapaciteit: 2U
AC-ingangsspanning: 100 - 240 V
AC-ingangsfrequentie: 50 - 60 Hz
Stroomverbruik (typisch): 40 W
Bedrijfstemperatuur (T-T): 0 - 50 °C
Relatieve vochtigheid in bedrijf (V-V): 5 - 90 procent
Code geharmoniseerd systeem (HS): 85176990

Heb je hulp nodig?

Als je hulp nodig hebt met Planet MC-700 stel dan hieronder een vraag en andere gebruikers zullen je antwoorden