Peerless ECMU-02-C Handleiding


Lees hieronder de 📖 handleiding in het Nederlandse voor Peerless ECMU-02-C (32 pagina's) in de categorie Flat panel steun. Deze handleiding was nuttig voor 15 personen en werd door 2 gebruikers gemiddeld met 4.5 sterren beoordeeld

Pagina 1/32
Installation and Assembly:
Wind Rated Concrete Ceiling Tilt Mount for 32" - 65" Outdoor
Flat Panel Displays
Models: ECMU-01-C, ECMU-01-C-S, ECMU-02-C, ECMU-02-C-S
ECMU-03-C, ECMU-03-C-S, ECMU-04-C, ECMU-04-C-S
ISSUED: 06-22-10 SHEET #: 061-9054-6 01-15-11
Max UL Load Capacity: 200 lb (90.7 kg)
Max Wind Rating: 90 mph, elevation 200 ft, Category D
©
UL
USC
2 of 32 ISSUED: 06-22-10 SHEET #: 061-9054-6 01-15-11
NOTE: Read entire instruction sheet before you start installation and assembly.
Tools Needed for Assembly
• phillips screwdriver, 3/16" allen wrench
• drill
• 3/8" (10 mm) drill bit
• level
• Do not begin to install your Peerless product until you have read and understood the instructions and warnings
contained in this Installation Sheet. If you have any questions regarding any of the instructions or warnings, for US
customers please call Peerless customer care at 1-800-865-2112, for all international customers, please contact
your local distributor.
• This product should only be installed by someone of good mechanical aptitude, has experience with basic building
construction, and fully understands these instructions.
• Due to outdoor environmental conditions such as strong wind gusts, heavy snow, hail, rain, etc. The environmental
enclosure, together with its mount, extension tube and hardware, must be inspected at least once a year, and
immediately following any time winds exceed 90 mph. A qualifi ed installer or inspector must check for signs of rust,
loose fasteners, bent metal, etc. If evidence of excessive wear, deterioration or any unsafe condition is observed,
this product must be taken out of service immediately. Direct all inquiries to customer care if you have any
questions.
• Make sure that the supporting surface will safely support the combined load of the equipment and all attached
hardware and components.
• Never exceed the Maximum UL Load Capacity. See page one.
• Always use an assistant or mechanical lifting equipment to safely lift and position equipment.
• Tighten screws fi rmly, but do not overtighten. Overtightening can damage the items, greatly reducing their holding
power.
• This product was designed for use with other outdoor products only.
• This product was designed to be installed on the following wall construction only;
WALL CONSTRUCTION HARDWARE REQUIRED
Solid Concrete Included
Other or unsure? Contact Qualifi ed Professional
WARNING
Table of Contents
Parts List.................................................................................................................................................................................3
Installation to Solid Concrete Surface ....................................................................................................................................4
Installing Tilt Brackets .............................................................................................................................................................6
Mounting and Removing Flat Panel Screen ...........................................................................................................................7
3 of 32 ISSUED: 06-22-10 SHEET #: 061-9054-6 01-15-11
ECMU-01-C
ECMU-02-C
ECMU-03-C
ECMU-04-C
ECMU-01-C-S
ECMU-02-C-S
ECMU-03-C-S
ECMU-04-C-S
Description Qty. Part # Part # Model # Part #
A
ceiling plate 1 061-T1306 061-7306 ECMU-01-C 061-T1266
Bsupport column 1 see chart see chart ECMU-01-C-S 061-7266
Cconcrete expansion anchor 8 5M9-381-H03 5M9-381-H03 ECMU-02-C 061-T1267
Dadapter box 1 061-T1264 061-7264 ECMU-02-C-S 061-7267
E5/16"-18 x 1" socket screw 4 520-5035 520-5035 ECMU-03-C 061-T1268
F7/16" x 4" hex head bolt 3 520-5014 520-5014 ECMU-03-C-S 061-7268
G7/16" nylock nut 3 530-5003 530-5003 ECMU-04-C 061-T1269
Hadapter plate 1 061-T125
8
061-725
8
ECMU-04-C-S 061-726
9
I1/4-20 x .75" socket screw 8 520-5034 520-5034
Jleft tilt bracket 1 061-T1383 061-7383
K
right tilt bracket 1 061-T1382 061-7382
Lsecurity allen wrench 1 560-9646 560-9646
MM6 x 12 mm socket pin screw 4 520-5023 520-5023
NM6 x 25 mm socket pin screw 4 520-5024 520-5024
OM8 x 15 mm socket pin screw 4 520-5026 520-5026
PM6 x 20 mm socket pin screw 4 520-5025 520-5025
QM8 x 25 mm socket pin screw 4 520-5027 520-5027
Rwasher 4 540-501
4
540-501
4
Support Column (B)
Parts List
B
Parts may appear slightly different than illustrated.
Before you begin, make sure all parts shown are included with your product.
C
A
D
F GE I
H
J
K
M N O RP Q
L


Product specificaties

Merk: Peerless
Categorie: Flat panel steun
Model: ECMU-02-C
Kleur van het product: Zwart
Gewicht verpakking: 29900 g
Montagewijze: Plafond
Maximale gewichtscapaciteit: 91 kg
Draaihoek: 360 °
Aantal displays ondersteund: 1
Bereik kantelhoek: 5 - 15 °
Maximale schermgrootte: 65 "
Minimale schermgrootte: 32 "
Maximum afstand tot plafond: 686 mm
Montage gatenpatroon (H x V): 720 x 449 mm

Heb je hulp nodig?

Als je hulp nodig hebt met Peerless ECMU-02-C stel dan hieronder een vraag en andere gebruikers zullen je antwoorden




Handleiding Flat panel steun Peerless

Handleiding Flat panel steun

Nieuwste handleidingen voor Flat panel steun