PNEUMATIC TOOL OPERATION INSTRUCTIONS
PPTEH PA22213A01
REV: 03 10-2015
PPTEH TENSION
PPTEH TENSION
PPTEH TENSION
PPTEH TENSION
PPTEH TENSION
AIR R EQUIRE D: MIN: 80 P SIG (5, 4 ba r)
AIR REQUI RED: M IN: 80 P SIG (5,4 ba r)
AIR REQUI RED: M IN: 80 P SIG (5,4 ba r)
AIR REQUI RED: M IN: 80 P SIG (5,4 ba r)
AIR REQUI RED: M IN: 80 P SIG (5,4 ba r)
M AX: 90 PS IG ( 6,1 ba r)
M AX: 90 P SIG ( 6,1 bar )
M AX: 90 P SIG ( 6,1 bar )
M AX: 90 P SIG ( 6,1 bar )
M AX: 90 P SIG ( 6,1 bar )
1 - 4 5 - 8
H EH
1
2
3
4
INTRODUCTION
The PPTEH Tool installs Panduit Heavy (H) and Extra Heavy
(EH) cross section cable ties (plastic tie down straps), for
medium to high volume cable tie applications. The tool
pneumatically tensions the cable tie to a tool-controlled
tension, and cuts off the tip.
GENERAL SAFETY PRACTICES
1. Tension Indicator 3. Hose Fitting
2. Selector Knob 4. Trigger
PPTEH Pneumatic Tool
• Only qualified and trained operators should install, adjust or use the pneumatic tool
• DO NOT modify this pneumatic tool. Modifications can reduce the effectiveness of safety measures and increase the risks
to the operator
• DO NOT discard the safety instructions; give them to the operator
• DO NOT use the pneumatic tool if it has been damaged
• Tools shall be inspected periodically to verify that the ratings and markings required by this part of ISO 11148 are legibly
marked on the tool. The employer/user shall contact the manufacturer to obtain replacement marking labels when
necessary
• DO NOT use tool for purposes not intended. Unexpected tool movement or breakage of tool may cause injuries to hand
• Unsuitable postures may not allow counteracting of normal or unexpected movement of the tool
For multiple hazards, read and understand the safety instructions before installing, operating, repairing, main-
taining, changing accessories on, or working near the pneumatic tool.
Safety glasses must be worn at all times by all persons within ten (10) feet of any part of the system.
CAUTION: Be aware of the ejection of cable tie scrap from tool.
DO NOT use tool on live electrical sources.
DO NOT place fingers near gripper during tool actuation. Fingers may be pinched by moving gripper.
DO NOT use tool in an explosive atmosphere.
Ear protection should be worn when operating the tool.
Projectile Hazards:
• Disconnect the pneumatic tool from the energy source when changing inserted tools or accessories
• Always wear impact-resistant eye protection during operation of the tool. The grade of protection required should be
assessed for each use
• Ensure that the workpiece is securely fixed
• Be aware that working on brittle material can cause harmful splinters
TOOL SPECIFICATIONS
Weight: 52 oz. (1474 gr.)
Dimensions*: 11.6” (294mm) Long X 8.6” (218mm) High
*Dimensions in parentheses are metric; all dimensions are
approximate, and for reference only.
• For multiple hazards, read and understand the safety
instructions before installing, operating, repairing,
maintaining, changing accessories on, or working near the
pneumatic tool. Failure to do so can result in serious
bodily injury.
Page: 2 of 4
© Panduit Corp. 2015 OPERATION INSTRUCTIONS PPTEH
OPERATION
1. Reading the selector knob from the bottom of the tool, flip the knob to
select the cross section of cable ties to be installed:
H: Approx. 0.30" (7,6 mm) and 0.35" (8,9 mm) wide cable ties
EH: Approx. 0.50" (12,7 mm) wide cable ties
If necessary, further adjust tension per Tension Adjustment
instructions below.
2. Loop cable tie around bundle and insert the tip through the head. Pull
the tie up snug on the bundle by hand.
3. Insert the strap of the cable tie into the side of the tool. With the nose
of the tool flush to the cable tie head, squeeze the trigger to tighten the
cable tie. Typically, only one depression of trigger is necessary for
cable tie cut-off.
SETUP
1. Connect 1/8” NPT male fitting of PPH10 Air Supply Hose to 1/8” NPT female port of PL289N1 Filter/Regulator.
2. Connect 1/8” female quick disconnect socket end of Air Supply Hose to 1/8” male quick disconnect plug at end of PPTEH
Tool.
3. Connect filter/regulator to main NON-LUBRICATED air supply and set regulator at 85 PSIG (5,9 bar). See Air Supply
specifications on Page 3.
Operating Hazards:
• Use of the tool may expose the operator’s hands to hazards, including impacts, cuts, abrasions and heat; wear
suitable gloves to protect hands
• Operators and maintenance personnel shall be physically able to handle the bulk, weight and power of the tool
• Hold the tool correctly; re ready to counteract normal or sudden movements and have both hands available
• Maintain a balanced body position and secure footing; avoid awkward or off-balanced postures, change posture during
extended tasks; this can help avoid discomfort and fatigue
• Use only lubricants recommended by the manufacturer
• Be aware of the risk of a whipping compressed air hose
Repetitive Motion Hazards:
• When using a pneumatic tool to perform work-related activities, the operator can experience discomfort in the hands, arms
shoulders, neck or other parts of the body
• While using a pneumatic tool, the operator should adopt a comfortable posture while maintaining secure footing and avoid-
ing awkward or off-balance postures. The operator should change posture during extended tasks; this can help avoid
discomfort and fatigue
• If the operator experiences symptoms such as persistent or recurring discomfort, pain, throbbing, aching, tingling,
numbness, burning sensations or stiffness; these warning signs should not be ignored. The operator should tell the
employer and consult a qualified health professional
Workplace Hazards:
• Slips, trips and falls are major causes of workplace injury. Be aware of slippery surfaces caused by use of the tool and also
of trip hazards caused by the air line or hydraulic hose
• Proceed with care in unfamiliar surroundings. There can be hidden hazards, such as electricity or other utility lines
• Ensure that there are no electrical cables, gas pipes, etc., which can cause a hazard if damaged by use of the tool
Additional Safety Instructions:
• Air under pressure can cause severe injury. Always shut off air supply, drain hose of air pressure and disconnect tool from
air supply when not in use, before changing accessories or when making repairs
• Whipping hoses can cause severe injury. Always check for damaged or loose hoses and fittings
• DO NOT exceed the maximum air pressure stated on the tool
• Never carry a pneumatic tool by the hose
Periodic Maintenance:
Make sure tool is clean before each use.
Page: 3 of 4
DAILY TOOL INSPECTION
1. Visually inspect nose area for foreign matter and cable tie scrap. Keep this area clear of foreign matter.
2. Visually inspect applied cable ties for correct tension and cut-off to verify the working condition of the blade and gripper.
KPPTEHB Blade Replacement Kit -
For replacement of a worn blade. ALL KITS SOLD SEPARATELY
CONTACT PANDUIT
FOR MORE INFORMATION.
KPPTEHG Gripper Replacement Kit -
For replacement of a worn gripper.
TTLK3 Tool Tension Locking Kit -
Install to prevent adjustment of the selector knob.
© Panduit Corp. 2015 OPERATION INSTRUCTIONS PPTEH
TECHNICAL SPECIFICATIONS - Air Supply
ITEM DESCRIPTION
Recommended regulated air pressure to tool (pressures other
than recommended may result in unsatisfactory operation):
Regulator settings: 85 PSIG (5,9 bar) with a max. 10 PSI (0,7
bar) drop. DO NOT EXCEED 90 PSIG
(6,2 bar).
Air consumption at 30 cycles per minute: 0.47 cfm @ 85 PSIG (0,222 l/sec @ 5,9 bar)
Line pressure to regulator: Minimum 80 PSIG (5,5 bar), Maximum 125 PSIG (8,6 bar)
Filter/regulator requirements: 5 micron maximum element rating, 5 PSI (0,3 bar) maximum
pressure drop @ 80 PSIG (5,5 bar) inlet pressure and 12 cfm
(5,7 l/sec) flow minimum.
Lubrication for air supply: Air line lubricators are NOT to be used.
Recommended filter/regulator unit (supplied by user) with 1/8”
NPT ports and 1/4” quick disconnect (industrial interchange)
plug:
Recommended source: Panduit Part Number PL289N1
Recommended main air supply hose (10 ft.) from filter/
regulator to tool (supplied by user); includes a 1/8” NPT male
connector (to regulator) and a 1/8” quick disconnect socket (to
tool):
Recommended source: Panduit Part Number PPH10
TENSION ADJUSTMENT
There is a tension indicator on the handle of the tool. The tension setting
can be adjusted by turning the selector knob:
1-4 for H; and 5-8 for EH.
OTHER SPECIFICATIONS
ITEM DESCRIPTION
Life cycle of the blade under normal operating conditions 100,000 cycles
Sound Level:
Measured sound level per ISO 15744. 73 dB
Vibration Level:
Measured vibration level per ISO 20643. 3.1 m/s2