Bekijk gratis de handleiding van Morco FEB-24E (49 pagina’s), behorend tot de categorie Ketel & boiler. Deze gids werd als nuttig beoordeeld door 8 mensen en kreeg gemiddeld 4.5 sterren uit 4.5 reviews. Heb je een vraag over Morco FEB-24E of wil je andere gebruikers van dit product iets vragen? Stel een vraag
Pagina 1/49

1
FEB-24E UK SUPERCOMPACT
COMBINATION BOILER
TECHNICAL & FAULTFINDING GUIDE
Morco Products Ltd
Riverview Road, Beverley, East Yorkshire, HU17 0LD
Telephone 01482 325456 Fax 01482 212869

2
Contents
1. Quick Guide to Trouble Shooting
2. Electrical Components
3. Central Heating Logic Programme
4. Explanation of Self Diagnostics
5. Self Diagnostic Flow Charts
ISSUE NUMBER 1.0

3
1. Quick Guide to Trouble shooting
This section outlines the most common problems and helps to guide you through the rest
of the workshop manual. (Read this section rst, before you make any adjustments. It
will save you time.)
CHECK HOT WATER SYSTEM FIRST, BEFORE THE CENTRAL HEATING CIRCUIT
HOT WATER SYSTEM
Here are some common problems:
GAS REGULATORS
Single appliance low capacity gas regulators plus 3/8” exible low pressure pipe, will
reduce the eciency dramatically. Ensure gas regulators and pipes are capable of
delivering 37mbar at the inlet under full load. A 2.5mbar drop is acceptable.
WATER FILTER
Check for contamination with foreign objects such as sawdust, plastic pipe swarf, etc. The
water lter is located inside the cold water inlet tting under the boiler. Any blockage will
reduce ow and may prevent the boiler ring up.
HOT AND COLD WATER CONNECTIONS
Connections may be reversed at the boiler inlet/outlet fittings, resulting in the boiler failing
to commence ignition sequence. This is because the hydraulic valve operates in one
direction only.
THERMOSTATIC SHOWER MIXER VALVE
Faulty non return valves within the mixer tap may allow mains cold water to enter the
domestic hot water pipe work. The boiler will react to the situation according to the
amount of mains water entering the system. In severe cases a high percentage of mains
cold water will exit the hot water tap in place of hot water, as water will always take the
path of least resistance. This will result in no hot water ow, or a very restricted flow
through the boiler. This will result in no ignition occurring or the boiler will modulate at very
low gas pressure, followed by the boiler eventually shutting down as insucient ow
passes through the boiler.
Product specificaties
Merk: | Morco |
Categorie: | Ketel & boiler |
Model: | FEB-24E |
Heb je hulp nodig?
Als je hulp nodig hebt met Morco FEB-24E stel dan hieronder een vraag en andere gebruikers zullen je antwoorden
Handleiding Ketel & boiler Morco
8 Juli 2023
8 Juli 2023
3 Juli 2023
3 Juli 2023
1 Juli 2023
30 Juni 2023
30 Juni 2023
29 Juni 2023
26 Juni 2023
15 Januari 2023
Handleiding Ketel & boiler
- Electrolux
- Vox
- Apricus
- Rheinstrom
- Keston
- Jocel
- Wijas
- Cata
- Stiebel Eltron
- AWB
- Sentry
- Hydrotherm
- Cola
- Hisense
- AEG
Nieuwste handleidingen voor Ketel & boiler
16 Juni 2025
15 Juni 2025
15 Juni 2025
15 Juni 2025
11 Juni 2025
11 Juni 2025
11 Juni 2025
11 Juni 2025
10 Juni 2025
10 Juni 2025