Mitsubishi MXZ-2F33VF Handleiding
Mitsubishi
Airco
MXZ-2F33VF
Bekijk gratis de handleiding van Mitsubishi MXZ-2F33VF (94 pagina’s), behorend tot de categorie Airco. Deze gids werd als nuttig beoordeeld door 46 mensen en kreeg gemiddeld 4.7 sterren uit 23.5 reviews. Heb je een vraag over Mitsubishi MXZ-2F33VF of wil je andere gebruikers van dit product iets vragen? Stel een vraag
Pagina 1/94

Models
MXZ-2F33VF - E1 , ET1
MXZ-2F42VF - E1 , ET1
MXZ-2F53VF - E1 , ET1
MXZ-2F53VFH - E1
MXZ-3F54VF - E1 , ET1
MXZ-3F68VF - E1 , ET1
MXZ-4F72VF - E1 , ET1
HFC
utilized
R32
SERVICE MANUAL
No. OBH790
OUTDOOR UNIT
NOTE:
RoHS compliant products have <G> mark
on the spec name plate.
PARTS CATALOG (OBB790)
Indoor unit service manual
MSZ-LN•VG Series (OBH766)
MSZ-EF•VG Series (OBH589)
MSZ-AP•VF Series (OBH799)
MSZ-AP•VG Series (OBH788)
MLZ-KP•VF Series (OBH801)
SLZ-M•FA Series
SEZ-M•DA Series
PCA-M•KA Series (OCH659)
PEAD-M•JA(L) Series (HWE16130)
CONTENTS
1. TECHNICAL CHANGES ··································· 3
2. SAFETY PRECAUTION ···································· 3
3. PART NAMES AND FUNCTIONS ··················· 13
4. SPECIFICATION ·············································· 14
5. NOISE CRITERIA CURVES ···························· 20
6. OUTLINES AND DIMENSIONS ······················ 22
7. WIRING DIAGRAM ·········································· 25
8. REFRIGERANT SYSTEM DIAGRAM ············· 29
9. PERFORMANCE CURVES ····························· 35
10. ACTUATOR CONTROL ··································· 56
11. SERVICE FUNCTIONS ···································· 57
12. TROUBLESHOOTING ····································· 61
13. DISASSEMBLY INSTRUCTIONS ···················· 86
MXZ-2F33VF
MXZ-2F42VF
MXZ-2F53VF MXZ-2F53VFH

2
<Preparation before the repair service>
Prepare the proper tools.
Prepare the proper protectors.
Provide adequate ventilation.
After stopping the operation of the air conditioner, turn o the power-supply breaker and remove the power plug.
Discharge the capacitor before the work involving the electric parts.
<Precautions during the repair service>
Do not perform the work involving the electric parts with wet hands.
Do not pour water into the electric parts.
Do not touch the refrigerant.
Do not touch the hot or cold areas in the refrigeration cycle.
When the repair or the inspection of the circuit needs to be done without turning o the power, exercise great caution not to
touch the live parts.
Use the specifi ed refrigerant only
Never use any refrigerant other than that specied.
Doing so may cause a burst, an explosion, or re when the unit is being used, serviced, or disposed of.
Correct refrigerant is specied in the manuals and on the spec labels provided with our products.
We will not be held responsible for mechanical failure, system malfunction, unit breakdown or accidents caused by
failure to follow the instructions.
OBH790

3
TECHNICAL CHANGES
1
MXZ-2F33VF - E1 , ET1
MXZ-2F42VF - E1 , ET1
MXZ-2F53VF - E1 , ET1
MXZ-2F53VFH - E1
MXZ-3F54VF - E1 , ET1
MXZ-3F68VF - E1 , ET1
MXZ-4F72VF - E1 , ET1
1. New model
2-1. ALWAYS OBSERVE FOR SAFETY
Before obtaining access to terminal, all supply circuits must be disconnected.
2SAFETY PRECAUTION
2-2. CAUTIONS RELATED TO NEW REFRIGERANT
Cautions for units utilizing refrigerant R32
Preparation before the repair service.
3UHSDUHWKHSURSHUWRROV
3UHSDUHWKHSURSHUSURWHFWRUV
3URYLGHDGHTXDWHYHQWLODWLRQ
$IWHUVWRSSLQJWKHRSHUDWLRQRIWKHDLUFRQGLWLRQHUWXUQRII
WKHSRZHUVXSSO\EUHDNHU
'LVFKDUJHWKHFRQGHQVHUEHIRUHWKHZRUNLQYROYLQJWKH
HOHFWULFSDUWV
Precautions during the repair service.
'RQRWSHUIRUPWKHZRUNLQYROYLQJWKHHOHFWULFSDUWV
ZLWKZHWKDQGV
'RQRWSRXUZDWHULQWRWKHHOHFWULFSDUWV
'RQRWWRXFKWKHUHIULJHUDQW
'RQRWWRXFKWKHKRWRUFROGDUHDVLQWKHUHIULJHUDWLQJF\FOH
:KHQWKHUHSDLURUWKHLQVSHFWLRQRIWKHFLUFXLWQHHGVWREH
GRQHZLWKRXWWXUQLQJRIIWKHSRZHUH[HUFLVHJUHDWFDXWLRQ
QRWWRWRXFKWKHOLYHSDUWV
Use new refrigerant pipes.
,QFDVHRIXVLQJWKHH[LVWLQJSLSHVIRU5EHFDUHIXOZLWK
WKHIROORZLQJ
Â%HVXUHWRFOHDQWKHSLSHVDQGPDNHVXUHWKDWWKHLQVLGHV
RIWKHSLSHVDUHFOHDQ
Â&KDQJHIODUHQXWWRWKHRQHSURYLGHGZLWKWKLVSURGXFW
8VHDQHZO\IODUHGSLSH
Â$YRLGXVLQJWKLQSLSHV
Use a vacuum pump with a reverse flow check
valve.
9DFXXPSXPSRLOPD\IORZEDFNLQWRUHIULJHUDQWF\FOHDQG
WKDWFDQFDXVHGHWHULRUDWLRQRIUHIULJHUDQWRLOHWF
MEANINGS OF SYMBOLS DISPLAYED ON THE UNIT
WARNING This mark is for R32 refrigerant only. Refrigerant type is written on nameplate of outdoor unit.
Read the OPERATION MANUAL carefully before operation.
Service personnel are required to carefully read the OPERATION MANUAL and INSTALLATION MANUAL before operation.
Further information is available in the OPERATION MANUAL, INSTALLATION MANUAL, and the like.
OBH790
Product specificaties
Merk: | Mitsubishi |
Categorie: | Airco |
Model: | MXZ-2F33VF |
Kleur van het product: | Wit |
Soort: | Buiteneenheid airconditioning |
Stroom: | 10 A |
Koelend medium: | R32 |
Inverter technologie: | Ja |
Multi-split: | Nee |
Air conditioner functies: | Cooling, Heating |
Ionisator: | Nee |
Jaarlijks energieverbruik (koelen): | 188 kWu |
Jaarlijks energieverbruik (verwarming) (warmer stookseizoen): | - kWu |
Jaarlijks energieverbruik (verwarming) (gemiddelde stookseizoen): | 980 kWu |
Extern geluidsniveau: | 60 dB |
Intern geluidsniveau (hoge snelheid): | - dB |
Koelcapaciteit in watt (opgegeven): | - W |
Verwarmingscapaciteit in watt (opgegeven) (warmer stookseizoen): | - W |
Verwarmingscapaciteit in watt (opgegeven) (gemiddelde stookseizoen): | - W |
Verwarmingscapaciteit in watt (opgegeven) (kouder stookseizoen): | - W |
Energieverbruik per uur (koeling): | - kWu |
Energieverbruik per uur (verwarming): | - kWu |
Bedrijfstemperatuur ( koeling ) ( T - T ): | -10 - 46 °C |
Compressor type: | Draaiknop |
Jaarlijks energieverbruik (verwarming) (kouder stookseizoen): | - kWu |
Ontwerpbelasting (koeling): | - kW |
Ontwerpbelasting (verwarming) (warmer stookseizoen): | - kW |
Ontwerpbelasting (verwarming) (gemiddelde stookseizoen): | - kW |
Ontwerpbelasting (verwarming) (kouder verwarmingsseizoen): | - kW |
Outdoor eenheid gewicht: | 33000 g |
Breedte buitenunit: | 800 mm |
Diepte buitenunit: | 285 mm |
Hoogte buiteneenheid: | 550 mm |
Outdoor units hoeveelheid: | 1 |
Wifi: | Nee |
AC-ingangsspanning: | 230 V |
AC-ingangsfrequentie: | 50 Hz |
Koelkast medium gewicht: | 1000 g |
Slanglengte (max): | 10 m |
Bedrijfstemperatuur (verwarming) (T-T): | -15 - 24 °C |
Buitenunit geluidsvermogensniveau: | 49 dB |
Gasslang diameter: | 9.52 mm |
Vloeistofslang diameter: | 6.35 mm |
Compressormotortype: | Borstelloos |
Heb je hulp nodig?
Als je hulp nodig hebt met Mitsubishi MXZ-2F33VF stel dan hieronder een vraag en andere gebruikers zullen je antwoorden
Handleiding Airco Mitsubishi
7 Mei 2025
7 Mei 2025
7 Mei 2025
27 Maart 2025
26 Maart 2025
26 Maart 2025
26 Maart 2025
19 Februari 2025
5 Februari 2025
9 Januari 2025
Handleiding Airco
- HTW
- Hisense
- Prime3
- Becken
- Arcelik
- Ocean Breeze
- Bavaria
- Royal Sovereign
- Braemar
- GoldAir
- Holland Electro
- HQ
- AFINTEK
- Crosley
- KuulAire
Nieuwste handleidingen voor Airco
17 Juni 2025
17 Juni 2025
16 Juni 2025
16 Juni 2025
16 Juni 2025
16 Juni 2025
16 Juni 2025
16 Juni 2025
16 Juni 2025
16 Juni 2025