Mitsubishi MSZ-SF50VE-E2 Handleiding

Mitsubishi Airco MSZ-SF50VE-E2

Lees hieronder de 📖 handleiding in het Nederlandse voor Mitsubishi MSZ-SF50VE-E2 (23 pagina's) in de categorie Airco. Deze handleiding was nuttig voor 63 personen en werd door 2 gebruikers gemiddeld met 4.5 sterren beoordeeld

Pagina 1/23
SPLIT-TYPE AIR CONDITIONERS
INDOOR UNIT
MSZ-SF25VE MSZ-SF35VE MSZ-SF42VE MSZ-SF50VE
Русский
Türkçe
Svenska
Dansk
Português
Ελληνικά
Italiano
Español
Nederlands
Français
Deutsch
English
OPERATING INSTRUCTIONS For user
To use this unit correctly and safely, be sure to read these operating in-
structions before use.
ИНСТРУКЦИИ ПО ЭКСПЛУАТАЦИИ Для пользователя
В целях правильной и безопасной эксплуатации данного устройс-
тва обязательно перед его использованием прочтите настоящее
руководство по эксплуатации.
ÇALIŞTIRMA TALİMATLARI Kullanıcı için
Bu üniteyi doğru ve venli bir bimde kullanmak in, kullanmadan
önce bu işletim talimatlarını okuduğunuzdan emin olun.
BRUKSANVISNING För användaren
Läs bruksanvisningen innan enheten tas i bruk att den används sä-
kert och på rätt sätt.
BETJENINGSVEJLEDNING Til kunden
• Læs denne betjeningsvejledningen før brug, så enheden bruges korrekt
og sikkert.
INSTRUÇÕES DE OPERAÇÃO Para o utilizador
• Para utilizar esta unidade correctamente e com segurança, certifique-
se de que lê estas instruções de operação antes da utilização.
ΟΔΗΓΙΕΣ ΛΕΙΤΟΥΡΓΙΑΣ Για το χρήστη
Για να χρησιμοποιήσετε αυτή τη μονάδα σωστά και με ασφάλεια, βεβαι-
ωθείτε ότι έχετε διαβάσει αυτό το εγχειρίδιο οδηγιών πριν από τη χρή-
ση.
LIBRETTO D’ISTRUZIONI Per gli utenti
Per utilizzare correttamente ed in tutta sicurezza questo apparecchio,
leggere il presente libretto d’istruzioni prima dell’uso.
MANUAL DE INSTRUCCIONES Para los clientes
• Para utilizar esta unidad de forma correcta y segura, lea previamente
estas instrucciones de funcionamiento.
BEDIENINGSINSTRUCTIES Voor de klant
Om dit apparaat correct en veilig te kunnen gebruiken moet u deze be-
dieningsinstructies voor gebruik eerst doorlezen.
NOTICE D’UTILISATION A l’attention des clients
Pour avoir la certitude d’utiliser cet appareil correctement et en toute
sécurité, veuillez lire cette notice d’instructions avant de mettre le clima-
tiseur sous tension.
BEDIENUNGSANLEITUNG For den Anwender
r einen sicheren und ordnungsgemäßen Gebrauch des Geräts unbe-
dingt diese Bedienungsanleitung vor der Inbetriebnahme durchlesen.
English is original.
Übersetzung des
Originals
Traduction du texte
d’origine
Vertaling van het
origineel
Traducción del
original
Traduzione
dell’originale
Μετάφραση του
αρχικού
Tradução do
original
Oversættelse af
den originale tekst
Översättning från
originalet
Orijinalin çevirisi
Перевод
оригинала
En-1
● OPERATING INSTRUCTIONS
WARNING
Do not connect the power cord to an intermediate point, use
an extension cord, or connect multiple devices to a single
AC outlet.
This may cause overheating, fi re, or electric shock.
Make sure the power plug is free of dirt and insert it securely
into the outlet.
A dirty plug may cause fi re or electric shock.
Do not bundle, pull, damage, or modify the power cord, and do
not apply heat or place heavy objects on it.
This may cause fi re or electric shock.
Do not turn the breaker OFF/ON or disconnect/connect the
power plug during operation.
This may create sparks, which can cause fi re.
After the indoor unit is switched OFF with the remote controller,
make sure to turn the breaker OFF or disconnect the power
plug.
Do not expose your body directly to cool air for a prolonged
length of time.
This could be detrimental to your health.
The unit should not be installed, relocated, disassembled,
altered, or repaired by the user.
An improperly handled air conditioner may cause re, electric
shock, injury, or water leakage, etc. Consult your dealer.
If the power supply cord is damaged, it must be replaced by the
manufacturer or its service agent in order to avoid a hazard.
When installing, relocating, or servicing the unit, make sure
that no substance other than the specifi ed refrigerant (R410A)
enters the refrigerant circuit.
Any presence of foreign substance such as air can cause abnor-
mal pressure rise and may result in explosion or injury.
The use of any refrigerant other than that specifi ed for the system
will cause mechanical failure, system malfunction, or unit break-
down. In the worst case, this could lead to a serious impediment
to securing product safety.
Since rotating parts and parts which could cause an electric shock are used
in this product, be sure to read these “Safety Precautions” before use.
Since the cautionary items shown here are important for safety, be sure to
observe them.
After reading this manual, keep it together with the installation manual in a
handy place for easy reference.
Marks and their meanings
WARNING : Incorrect handling could cause serious hazard, such as
death, serious injury, etc. with a high probability.
CAUTION : Incorrect handling could cause serious hazard depending
on the conditions.
This appliance is not intended for use by persons (including
children) with reduced physical, sensory or mental capabilities,
or lack of experience and knowledge, unless they have been
given supervision or instruction concerning use of the appli-
ance by a person responsible for their safety.
Children should be supervised to ensure that they do not play
with the appliance.
Do not insert your nger, a stick, or other objects into the air
inlet or outlet.
This may cause injury, since the fan inside rotates at high speeds
during operation.
In case of an abnormal condition (such as a burning smell),
stop the air conditioner and disconnect the power plug or turn
the breaker OFF.
A continued operation in the abnormal state may cause a malfunc-
tion, re, or electric shock. In this case, consult your dealer.
When the air conditioner does not cool or heat, there is a pos-
sibility of refrigerant leakage. In this case, consult your dealer.
If a repair involves recharging the unit with refrigerant, ask the
service technician for details.
The refrigerant used in the air conditioner is safe. Normally, it does
not leak. However, if refrigerant leaks and comes in contact with
a heat source such as a fan heater, kerosene heater, or cooking
stove, it will create a harmful gas.
The user should never attempt to wash the inside of the indoor
unit. Should the inside of the unit require cleaning, contact
your dealer.
Unsuitable detergent may cause damage to plastic material inside
the unit, which may result in water leakage. Should detergent
come in contact with electrical parts or the motor, it will result in
a malfunction, smoke, or fi re.
CAUTION
Do not touch the air inlet or the aluminum ns of the indoor/
outdoor unit.
This may cause injury.
Do not use insecticides or fl ammable sprays on the unit.
This may cause a fi re or deformation of the unit.
Meanings of symbols used in this manual
: Be sure not to do.
: Be sure to follow the instruction.
: Never insert your fi nger or stick, etc.
:
Never step onto the indoor/outdoor unit and do not put anything on them.
: Danger of electric shock. Be careful.
: Be sure to disconnect the power supply plug from the power outlet.
: Be sure to shut off the power.
SAFETY PRECAUTIONS
CONTENTS
N SAFETY PRECAUTIONS 1
N DISPOSAL 2
N NAME OF EACH PART 3
N PREPARATION BEFORE OPERATION 3
N SELECTING OPERATION MODES 4
N FAN SPEED AND AIRFLOW DIRECTION ADJUSTMENT 5
N I-SAVE OPERATION 6
N ECONO COOL OPERATION 6
N TIMER OPERATION (ON/OFF TIMER) 6
N WEEKLY TIMER OPERATION 7
N CLEANING 8
N WHEN YOU THINK THAT TROUBLE HAS OCCURRED 9
N WHEN THE AIR CONDITIONER IS NOT GOING TO BE USED FOR A LONG TIME 10
N INSTALLATION PLACE AND ELECTRICAL WORK 10
N SPECIFICATIONS 10
En-2
Your MITSUBISHI ELECTRIC product is designed and manufactured with high
quality materials and components which can be recycled and/or reused.
This symbol means that electrical and electronic equipment, batteries and
accumulators, at their end-of-life, should be disposed of separately from your
household waste.
If a chemical symbol is printed beneath the symbol (Fig. 1), this chemical sym-
bol means that the battery or accumulator contains a heavy metal at a certain
concentration. This will be indicated as follows:
Hg: mercury (0,0005%), Cd: cadmium (0,002%), Pb: lead (0,004%)
In the European Union there are separate collection systems for used electrical
and electronic products, batteries and accumulators.
Please, dispose of this equipment, batteries and accumulators correctly at your
local community waste collection/recycling centre.
Please, help us to conserve the environment we live in!
Note:
This symbol mark is for EU countries only.
This symbol mark is according to the directive 2002/96/
EC Article 10 Information for users and Annex IV, and/
or to the directive 2006/66/EC Article 20 Information for
end-users and Annex II.
CAUTION
Do not expose pets or houseplants to direct airfl ow.
This may cause injury to the pets or plants.
Do not place other electric appliances or furniture under the
indoor/outdoor unit.
Water may drip down from the unit, which may cause damage or
malfunction.
Do not leave the unit on a damaged installation stand.
The unit may fall and cause injury.
Do not step on an unstable bench to operate or clean the unit.
This may cause injury if you fall down.
Do not pull the power cord.
This may cause a portion of the core wire to break, which may
cause overheating or fi re.
Do not charge or disassemble the batteries, and do not throw
them into a re.
This may cause the batteries to leak, or cause a re or explo-
sion.
Do not operate the unit for more than 4 hours at high humid-
ity (80% RH or more) and/or with windows or outside door left
open.
This may cause the water condensation in the air conditioner, which
may drip down, wetting or damaging the furniture.
The water condensation in the air conditioner may contribute to
growth of fungi, such as mold.
Do not use the unit for special purposes, such as storing food,
raising animals, growing plants, or preserving precision devices
or art objects.
This may cause deterioration of quality, or harm to animals and
plants.
Do not expose combustion appliances to direct airfl ow.
This may cause incomplete combustion.
Never put batteries in your mouth for any reason to avoid ac-
cidental ingestion.
Battery ingestion may cause choking and/or poisoning.
Before cleaning the unit, switch it OFF and disconnect the power
plug or turn the breaker OFF.
This may cause injury, since the fan inside rotates at high speeds
during operation.
When the unit will be unused for a long time, disconnect the
power plug or turn the breaker OFF.
The unit may accumulate dirt, which may cause overheating or
re.
Replace all batteries of the remote controller with new ones of
the same type.
Using an old battery together with a new one may cause overheat-
ing, leakage, or explosion.
If the battery uid comes in contact with your skin or clothes,
wash them thoroughly with clean water.
If the battery uid comes in contact with your eyes, wash them
thoroughly with clean water and immediately seek medical atten-
tion.
Ensure that the area is well-ventilated when the unit is operated
together with a combustion appliance.
Inadequate ventilation may cause oxygen starvation.
Turn the breaker OFF when you hear thunder and there is a pos-
sibility of a lightning strike.
The unit may be damaged if lightning strikes.
To dispose of this product, consult your dealer.
WARNING
Consult your dealer for installing the air conditioner.
It should not be installed by the user since installation requires
specialized knowledge and skills. An improperly installed air con-
ditioner may cause water leakage, fi re, or electric shock.
Provide a dedicated power supply for the air conditioner.
A non-dedicated power supply may cause overheating or fi re.
Do not install the unit where ammable gas could leak.
If gas leaks and accumulates around the outdoor unit, it may cause
an explosion.
Earth the unit correctly.
Do not connect the earth wire to a gas pipe, water pipe, lightning
rod, or a telephone ground wire. Improper earthing may cause
electric shock.
CAUTION
Install an earth leakage breaker depending on the installation
location of the air conditioner (such as highly humid areas).
If an earth leakage breaker is not installed, it may cause electric
shock.
Ensure that the drain water is properly drained.
If the drain passage is improper, water may drip down from the
indoor/outdoor unit, wetting and damaging the furniture.
In case of an abnormal condition
Immediately stop operating the air conditioner and consult your dealer.
SAFETY PRECAUTIONS
After the air conditioner is used for several seasons, perform
inspection and maintenance in addition to normal cleaning.
Dirt or dust in the unit may create an unpleasant odor, contribute
to growth of fungi, such as mold, or clog the drain passage, and
cause water to leak from the indoor unit. Consult your dealer for
inspection and maintenance, which require specialized knowledge
and skills.
Do not operate switches with wet hands.
This may cause electric shock.
Do not clean the air conditioner with water or place an object that
contains water, such as a fl ower vase, on it.
This may cause fi re or electric shock.
Do not step on or place any object on the outdoor unit.
This may cause injury if you or the object falls down.
DISPOSAL
For installation
Fig. 1
IMPORTANT
Dirty lters cause condensation in the air conditioner which will contribute
to the growth of fungi such as mold. It is therefore recommended to clean air
lters every 2 weeks.
Before starting the operation, ensure that the horizontal vanes are in the closed
position. If operation starts when the horizontal vanes are in the open position,
they may not return to the correct position.


Product specificaties

Merk: Mitsubishi
Categorie: Airco
Model: MSZ-SF50VE-E2
Kleur van het product: Wit
Soort: Binneneenheid airconditioning
Inverter technologie: Ja
Air conditioner functies: Cooling, Heating
Seizoensgebonden rendement (koeling) (SEER): 7.2
Seasonal efficiency rating (verwarming) (SCOP) (gemiddeld stookseizoen): 4.4
Energie-efficiëntieklasse (verwarming) (gemiddelde stookseizoen): A+
Jaarlijks energieverbruik (koelen): - kWu
Jaarlijks energieverbruik (verwarming) (gemiddelde stookseizoen): - kWu
Energie-efficiëntieklasse (koeling): A++
Intern geluidsniveau (hoge snelheid): 45 dB
Op afstand bedienbaar: Ja
Energieverbruik per uur (koeling): 1.66 kWu
Energieverbruik per uur (verwarming): 1.7 kWu
Breedte binnenunit: 798 mm
Diepte binnenunit: 195 mm
Hoogte binnenunit: 299 mm
Bedrijfstemperatuur ( koeling ) ( T - T ): -10 - 46 °C
Koel capaciteit in watt (max): 5000 W
Verwarmingscapaciteit in watt (max): 5800 W
Indoor unit type: Muur-montage
Indoor eenheid gewicht: 10000 g
Indoor units hoeveelheid: 1
AC-ingangsspanning: 220-240 V
AC-ingangsfrequentie: 50 Hz
Bedrijfstemperatuur (verwarming) (T-T): -15 - 24 °C

Heb je hulp nodig?

Als je hulp nodig hebt met Mitsubishi MSZ-SF50VE-E2 stel dan hieronder een vraag en andere gebruikers zullen je antwoorden




Handleiding Airco Mitsubishi

Handleiding Airco

Nieuwste handleidingen voor Airco