Minuteman ED3000RM2UNC Handleiding

Minuteman UPS ED3000RM2UNC

Lees hieronder de 📖 handleiding in het Nederlandse voor Minuteman ED3000RM2UNC (17 pagina's) in de categorie UPS. Deze handleiding was nuttig voor 55 personen en werd door 2 gebruikers gemiddeld met 4.5 sterren beoordeeld

Pagina 1/17
User's Manual
Endeavor Series
Para Systems, Inc.
1455 Lemay Dr.
Carrollton, TX 75007
Phone: 1-972-446-7363
Fax: 1-972-446-9011
Internet: minutemanups.com
UPS Sizing: sizemyups.com
PN - 34000274
On-Line UPS
1
© Copyright 2006
1. Introduction 2
2. Controls and Indicators 6
3. Installation 9
4. Operation 15
5. Troubleshooting 18
6. Replacing the Battery 19
7. Obtaining Service 22
8. Specifications 23
9. Configurable Parameters & Settings 25
10. Limited Product Warranty 26
A1. Declaration of Conformity 28
English
23
IMPORTANT SAFETY INSTRUCTIONS
SAVE THESE INSTRUCTIONS !
WARNING: Risk of Electrical Shock. Hazardous live parts inside
these power supplies are energized from the battery even when the
AC input is disconnected.
CAUTION! To de-energize the outputs of the UPS:
1. If the UPS is on press and release the Off button. NOTE: For the
208V models; turn the input circuit breaker to the off position.
2. Disconnect the UPS from the AC wall outlet.
3. To de-energize the UPS completely, disconnect the battery.
CAUTION! To reduce the risk of electrical shock in conditions
where the load equipment grounding cannot be verified, disconnect
the UPS from the AC wall outlet before installing a computer interface
cable. Reconnect the power cord only after all signaling connections
are made.
CAUTION! Connect the UPS to a two pole, three wire grounding
AC wall outlet. The receptacle must be connected to the appropriate
branch protection (circuit breaker or fuse). Connection to any other
type of receptacle may result in a shock hazard and violate local
electrical codes. Do not use extension cords, adapter plugs, or surge
strips.
English
English
Thank you for purchasing this power protection product. It has been designed
and manufactured to provide many years of trouble free service.
Please read this manual before installing your Endeavor On-Line Series UPS,
models ED1000RM2U, ED1000RMT2U, ED1500RM2U, ED1500RMT2U,
ED2000RM2U, ED2000RMT2U, ED3000RM2U, ED3000RMT2U as it provides
important information that should be followed during installation and mainte-
nance of the UPS and batteries allowing you to correctly set up your system for
the maximum safety and performance. Included is information on customer
support and factory service if it is required. If you experience a problem with the
UPS please refer to the Troubleshooting guide in this manual to correct the
problem or collect enough information so that the Technical Support Depart-
ment can rapidly assist you.
CAUTION! To reduce the risk of electrical shock with the installa-
tion of this UPS equipment and the connected equipment, the user
must ensure that the combined sum of the AC leakage current does
not exceed 3.5mA.
This symbol indicates "ATTENTION"
This symbol indicates "Risk of Electrical Shock"
This symbol indicates "Alternating Current Supply"
This symbol indicates "Direct Current Supply"
This symbol indicates "Alternating Current Supply Phase"
This symbol indicates "Equipment Grounding Conductor"
WARNING: This Uninterruptible Power Supply contains potentially
hazardous voltages. Do not attempt to disassemble the UPS beyond
the battery replacement procedure. This UPS contains no user ser-
viceable parts. Repairs and Battery replacement must be performed
by QUALIFIED SERVICE PERSONNEL ONLY.


Product specificaties

Merk: Minuteman
Categorie: UPS
Model: ED3000RM2UNC

Heb je hulp nodig?

Als je hulp nodig hebt met Minuteman ED3000RM2UNC stel dan hieronder een vraag en andere gebruikers zullen je antwoorden




Handleiding UPS Minuteman

Handleiding UPS

Nieuwste handleidingen voor UPS