BM70/71 & IS1870/71 rmware 2.03 Release Notes Fi – July 22, 20 20
IS1870/71 & BM70/71 Firmware 2.03
Release Notes
1 Overview
Firmware version 2.0 is a maintenance release for IS1870, IS1871, BM70, and BM71. Firmware
version 2.0 adds new features/ removes limitations in previous release 1.11. This firmware is made
available on Microchip’s web site for existing IC’s and modules.
1.1 Resolved Issues
• Fixed read ADC command problem for temperature detection.
• Fixed Sweyntooth BLE vulnerabilities in LL, SMP and L2CAP layers.
• Fixed disconnection issue with Xiaomi Mi 10 Pro Phone.
• Fixed MPAF OTA update UI fail issue.
• Fixed HID over GATT issue.
• Fixed an issue where pairing fails in Multilink scenario with reason DHKey failure check.
• Fixed Instant Pass Issue for Multilink scenarios (LL_STATUS_ERROR_INSTANT_PASSED/0x28)
• IOP Pairing fail issue with Samsung S8 Verizon variant.
• Write to Flash is enabled for few manual pattern commands like WRITE DEVICE NAME
command (0x08).
• Fixed issue where AutoPattern Mode BM70 outputs manual mode data from UART.
• Fixed an issue where the application always starts passive scan irrespective of whether scan
type is set to passive or active.
• Fixed an issue where the SCAN_RES is displayed as ADV_IND.
• Fixed an issue where ADC return value was shown incorrectly.
• Fixed an issue where connection was getting terminated due to MIC failure in Multilink scenario.
1.2 New Features
• BLE Data Length Extension to max 251 bytes.
• Maximum BLE ATT MTU size is 247 bytes
• AFH channel map adjust automatically when BLEDK3 is Central role ed
• Supports LE privacy feature v1.1 (disabled by default in UI settings)
• Enhance data transmission throughput in Auto pattern mode
• Supports following in auto pattern mode
o BLEDK3 v2.0 to be GAP Central role
o It allows two nearby BLEDK3 v2.0 devices with auto pattern to establish BLE link
BM70/71 & IS1870/71 rmware 2.03 Release Notes Fi – July 22, 20 20
automatically
• Multi-link/Multi-role capability in Manual mode
o Maximum 4 BLE links can exist simultaneously (with Multi-link device as Central for all
links). When the multi-link device is in Peripheral role for at least one link the maximum
number of links is limited to 2. Below shows the valid combination of multi-link possibility
BLE multi-link
BLEDK3 v2.0 Role
Other peer devices
Note
Case 1
One BLE link
Central
Peripheral
OK
Peripheral
Central
OK
Case 2
Two BLE links
Central
Two independent
Peripherals
OK
Peripheral
Two independent
Centrals
Sometimes link loss
happened within 1 hour
Parallel Central and
Peripheral
Two independent
Peripheral and
Central
Sometimes link loss
happened within 1 hour
Case 3
Three BLE links
Central
Three independent
Peripherals
OK
Case 4
Four BLE links
Central
Four independent
Peripherals
OK
Note: Multilink scenario with BM70 as Central for two links and Peripheral for third link is also
supported. Limitations apply.
• Added new UART commands in Manual mode
• Queued writes are enabled (Queued writes now enabled for characteristics within a service)
• Auto pattern data to be transmitted only when End of data is indicated using GPIO.
Note: Auto pattern Test tool does not support this feature. However, when MCU application is
implemented this feature can be used.
• Added UART Parity and Stop bit configuration in UI tool.
Note: Parity enabling is not supported in Manual pattern Test tool /Auto Test pattern tool as
these tool access the MCP 2200 UART to USB converter. MCP 2200 supports fixed stop bit and
does not support parity.
BM70/71 & IS1870/71 rmware 2.03 Release Notes Fi – July 22, 20 20
1.3 Known Issues and Limitation
• [Phone]
o Max to 251 bytes Data Length just may be supported in Android 6.x and iPhone 7 later,
but the actual LE data packet length transmitted between BLEDK3 v2.0 and smart phone
still referring to the result of Data Length Update procedure.
• [BLEDK3 v2.0]
o If LE privacy feature v1.1 is enabled, with Auto Pattern application of BLEDK3 v2.0,
random privacy address will be the same after every boot up of system, because random
privacy address uses system clock as seed to generate random number
• [BLEDK3 v2.0][Manual Pattern]
o For multi-link case 4 with lower baud rate, while BLEDK3 v2.0 (Central) transmits large
block size data bilaterally with each Peripheral at the same time, BLEDK3 v2.0 (Central)
may run out of Heap memory after long time period
• [BLEDK3 v2.0][Auto Pattern]
o If BLEDK3 v2.0 use trust device feature, after disconnection occurs with unbonded
remote device, BLEDK3 v2.0 will fail to respond LE protocol with bonded device and
then cause the abnormal disconnection
• When both Scan and advertising are enabled at the same time and device connects as Central,
state indicates standby but device is not advertising
o Workaround: Exit standby mode and enter standby mode again to start advertising .
• OTA is supported only for application bank. Complete BLEDK3 2.0 firmware cannot be upgraded
with OTA.
1.4 PC Tools
Firmware 2.0 is used with the following PC tools included in the firmware package, or downloaded
from the appropriate product pages below.
• IS187x_202_BLEDK3v2.00_UI v2.13 Configuration Editor for IS187x/BM7x
• BLEDK3 Manual Test Tool v0.49 Utility to test Manual Pattern Commands
• BLEDK3 Auto Pattern Test Tool v1.0_009 Utility to test Auto Pattern Mode Commands
1.5 Ordering Information
At the time of this publication 2.03 is released only as a firmware image on the product pages below.
Contact your Microchip representative if 2.03 is required on BM70/71 module.
• www.microchip.com/BM70
• www.microchip.com/BM71
• www.microchip.com/IS1870
• www.microchip.com/IS1871
1.6 Firmware Up e dat
BM70_71 modules and EVB, such as PICTails, can be updated to firmware 2.03 using the PC Utilities
mentioned previously. The utilities are provided in the firmware package that can be downloaded
from the appropriate product pages described above. To perform a firmware update follow the
instructions provided in the firmware release.


Product specificaties

Merk: Microchip
Categorie: Niet gecategoriseerd
Model: IS1870

Heb je hulp nodig?

Als je hulp nodig hebt met Microchip IS1870 stel dan hieronder een vraag en andere gebruikers zullen je antwoorden




Handleiding Niet gecategoriseerd Microchip

Handleiding Niet gecategoriseerd

Nieuwste handleidingen voor Niet gecategoriseerd