Mabis 60-Second Digital Handleiding

Mabis Thermometers 60-Second Digital

Lees hieronder de 📖 handleiding in het Nederlandse voor Mabis 60-Second Digital (1 pagina's) in de categorie Thermometers. Deze handleiding was nuttig voor 62 personen en werd door 2 gebruikers gemiddeld met 4.5 sterren beoordeeld

Pagina 1/1
TAKING A RECTAL TEMPERATURE
Rectal temperatures should only be taken when it is impossible or impractical to
take an oral or axillary temperature. THE THERMOMETER TIP SHOULD BE
INSERTED A MAXIMUM OF 1/2” INTO THE RECTUM. The temperature reading
should take approximately sixty seconds. The oF will continue to flash during the
reading of the temperature. When the peak temperature has been reached, the
oF will stop flashing and the thermometer will sound four long beeps if the tem-
perature is below 99.5oF. If the temperature is above 99.5oF the unit will sound
four sets of three short beeps each. To turn the unit off, press the POWER but-
ton. The unit will automatically power down after approximately ten minutes.
REMEMBER: Rectal temperatures are generally
1.0
o
F
higher than oral readings.
USING DISPOSABLE PROBE COVERS
It is recommended to use disposable probe covers in order to prevent cross
contamination. Probe covers can be purchased from your MABIS dealer or with
the order form below.
CHANGING THE BATTERY
The battery in your digital thermometer needs to
be replaced when ” appears in the lower right
of the display. Replace the battery with an LR41
alkaline or SR41 silver oxide type. To replace the
battery, slide the battery cap away from the unit.
Remove the battery using a non-metal tool. Insert
the new battery with the positive (+) side facing up. Carefully slide the battery
cap back into place.
SPECIFICATIONS
DISPLAY: LIQUID CRYSTAL DISPLAY
DISPLAY RESOLUTION: 4 DIGITS (1/10 OF A DEGREE INCREMENTS)
MEASUREMENT RANGE: 89.6˚F to 111.2˚F
ACCUR ACY: ±0.2˚F BETWEEN 95.9˚F AND 107.6˚F
BATTERY: ONE 1.5V BUTTON SIZE BATTERY
LR41 OR EQUIVALENT
BATTERY LIFE: APPROXIMATELY 24 MONTHS
AUTOMATIC SHUT-OFF: AFTER APPROXIMATELY TEN MINUTES
OPERATING TEMPERATURE: 50.0˚F 104.0˚F
STORAGE TEMPERATURE: 14.0˚F – 140.0˚F
DIMENSIONS: 5-1/8” X 3/4” X 3/8”
WEIGHT: 0.38 OUNCES
Specifications are subject to change without notice.
PARTS OF YOUR DIGITAL THERMOMETER
BODY TEMPERATURE
Body temperature can vary from 97oF to 99oF. The generally accepted “normal”
temperature is 98.6oF. Usually your temperature is lower in the morning than in
the afternoon. Normal temperature varies according to the location of the tem-
perature reading. While the oral temperature follows the guidelines previously
described, a rectal temperature is generally 1.0o
F higher. Conversely, an axillary
(under the arm) temperature will be 1.0oF lower.
GENERAL CARE AND USE
The thermometer should be held during use. The patient should be seated or
lying down. TEMPERATURES SHOULD ONLY BE TAKEN UNDER THE SUPER-
VISION OF AN ADULT.
You can clean your Digital Thermometer by wiping it with soap and water or 70%
Isopropyl Alcohol. THE UNIT MUST NEVER BE SUBMERSED IN ANY LIQUID OR
STERILIZED IN ANY WAY (GAS OR STEAM AUTOCLAVES). Failure to follow
these instructions will cause severe damage to your unit and void your warranty.
1. The thermometer should only be used under the supervision of an adult.
2. Do not walk, run or talk during temperature taking.
3. Clean the thermometer before and after each use.
4. Store the unit in the protective case when not in use.
5. Do not bite the thermometer tip.
6. Do not store the unit where it will be exposed to direct sunlight, dust or humidity.
Avoid extreme temperatures.
7. Dropping or subjecting your thermometer to strong shocks should be avoided.
8. Do not attempt to disassemble the unit, except to replace the battery.
9. If ERR displays and measurement is not attainable, the unit must be replaced.
NOTE: Performance of the device may be degraded if: operated outside of the stated
termperature and humidity range; stored outside of stated temperature and humidity
range; thermometer undergoes mechanical shock (drop); patient temperature is below
ambient temperature.
OPERATING YOUR DIGITAL THERMOMETER
Press the POWER button to activate the thermometer. The dig-
ital display will show the following and the thermometer will
beep.
This is the LCD display test. This insures all parts of the display
are functioning properly.
By continuing to hold the button down, the last measured tem-
perature will be displayed until the button is released.
Once the button is released or if no reading is stored, an L with a flashing oF will
appear in the display followed by a brief flash of 97.7oF followed by an L with a
flashing oF to indicate that the thermometer is ready for measurement.
NOTE: If the room temperature is above 89.6oF, the room temperature will dis-
play instead of the L.
TAKING AN ORAL TEMPERATURE
Using the diagram on the right, place the ther-
mometer tip under the tongue as near as possible to
the heat pocket. The diagram also shows the tem-
perature variables by not placing the tip in the heat
pocket area. The temperature reading should take
approximately sixty seconds. The oF will continue to
flash during the reading of the temperature. When
the peak temperature has been reached, the o
F will
stop flashing and the thermometer will sound four
long beeps if the temperature is below 99.5
oF. If the
temperature is above 99.5oF the unit will sound four
sets of three short beeps each. To turn the unit off, press the POWER button. The
unit will automatically power down after approximately ten minutes. NOTE: The
mouth must remain closed during the measurement to insure accurate readings.
TAKING AN AXILLARY TEMPERATURE (under the arm)
The thermometer tip should be placed under the arm so the tip is touching the
skin. Hold the thermometer parallel to the body and position the arm on the chest
so the probe tip is well covered by the arm. This insures the thermometer tip is
not affected by the room air. The temperature reading should take approximate-
ly sixty seconds. The oF will continue to flash during the reading of the
tempera-
ture. When the peak temperature has been reached, the
oF
will stop flashing and
the thermometer will sound four long beeps if the temperature is below
99.5oF
. If
the temperature is above
99.5oF
the unit will sound four sets of three short beeps
each. To turn the unit off, press the POWER button. The unit will automatically
power down after approximately ten minutes. REMEMBER: Axillary temperatures
are generally 1.0
o
F lower than oral readings.
PROBE TIP DIGITAL DISPLAY WINDOW POWER BUTTON
BA TTERY COVER
HEA T
POCKET
HEAT
POCKET
98.4o F 98.4oF
98.8 o
F98.8
oF
97.9oF
97.7oF
97.9oF
98.1oF
LIMITED ONE-YEAR WARRANTY
This Digital Thermometer is guaranteed to be free of manufacturing defects for a period of one
year from the date of purchase under normal use. This warranty applies to the original registered
purchaser only. All repairs on your Digital Thermometer should be sent prepaid to: MABIS
Healthcare Inc., Attn: Repair Department, 1931 Norman Drive, Waukegan, IL 60085.
The warrantor shall incur no liability under this warranty for any damage from any cause other
than inherent manufacturing defects.
ALL IMPLIED WARRANTIES, INCLUDING MERCHANTABILITY AND FITNESS ARE LIMITED TO
THE DURATION OF THIS WARRANTY. THIS WARRANTY DOES NOT INCLUDE ANY LIABILITY
FOR INCIDENTAL OR CONSEQUENTIAL DAMAGES. Some states do not allow limitation on how
long an implied warranty lasts or do not allow the exclusion or limitation of incidental or
consequential damages, so the above limitations or exclusions may not apply to you.
This warranty gives you specific legal rights and you may also have other rights which vary from
state to state.
Digital Thermometer
CUT OUT AND MAIL TO: MABIS HEALTHCARE INC.
1931 NORMAN DRIVE
WAUKEGAN, IL 60085
THERMOMETER WARRANTY REGISTRATION
(MUST BE COMPLETED WITHIN 10 D AYS OF PURCHASE)
NAME:
ADDRESS:
CITY: STATE: ZIP:
PURCHASED FROM:
CITY: STATE: ZIP:
DATE PURCHASED:
USER INFORMATION (OPTIONAL)
❑ ❑MALE FEMALE AGE:
AGE OF YOUNGEST FAMILY MEMBER
UNDER 6 MONTHS6 MONTHS - 1 YEAR
❑ ❑ ❑1 - 3 YEARS 3 - 5 YEARS OLDER
#MABMT-118-BF 05/04
PROBE COVER ORDER FORM
CUT OUT AND MAIL TO: MABIS HEALTHCARE INC.
1931 NORMAN DRIVE
WAUKEGAN, IL 60085
Please send packages of disposable probe covers
#15-618-000 (100 probes per package). Enclosed is $5.00 per
package plus $3.00 for shipping and handling for each order.
PAYMENT METHOD (do not send cash): Check Money Order
Please ship to:
NAME:
ADDRESS:
CITY: STATE: ZIP:
PHONE: ( )
NOTE: This order form is for shipments within the United States and Canada.
#MABMT-118-BF 05/04
©2004 MABIS Healthcare Inc.


Product specificaties

Merk: Mabis
Categorie: Thermometers
Model: 60-Second Digital

Heb je hulp nodig?

Als je hulp nodig hebt met Mabis 60-Second Digital stel dan hieronder een vraag en andere gebruikers zullen je antwoorden