Bekijk gratis de handleiding van Little Giant 6EC-CIM (32 pagina’s), behorend tot de categorie Waterpomp. Deze gids werd als nuttig beoordeeld door 7 mensen en kreeg gemiddeld 4.6 sterren uit 4 reviews. Heb je een vraag over Little Giant 6EC-CIM of wil je andere gebruikers van dit product iets vragen? Stel een vraag
Pagina 1/32

6EC & 10EC Series Sump Pumps
OWNER'S MANUAL
English
EN
This submersible pump is for use in basins or lift stations and is
suitable for pumping clear water or effluent gray water with up
to ½-inch spherical semi-solids. Do not use the pump in appli-
cations where sewage or any other debris (gravel, sand, float-
ing debris, etc.), abrasives, or corrosives are present.
The pump motor is equipped with an automatic resetting ther-
mal protector and may restart unexpectedly.
Do not use the 6EC-CIA-DS pumps in applications where efflu-
ent gray water or sewage or any other debris (gravel, sand,
floating debris, etc.), abrasives, or corrosives are present.
This product is covered by a Limited Warranty for a period of 3 years from the date of original purchase by
the consumer. For complete warranty information, refer to www.LittleGiant.com
.
Specifications
Model HP Volts Amps Watts PSI
Shut Off
ft (m)
ON Level
inches (cm)
OFF Level
inches (cm)
Discharge
6EC-CIA-RF
1/3
115
5 600 12.1 28 (8.5)
13-15
(33-38)
6-8
(15-20)
1½-inch
FNPT
6EC-CIA-SFS
8-11
(20-28)
2-5
(5-13)
6EC-CBA-SFS
6EC-CIA-DS
3-6
(8-15)
6EC-CIM
- -
6EC-CBM
10EC-CIA-RF
1/2 6.5 750 15.6 36 (11)
13-15
(33-38)
6-8
(15-20)
10EC-CIA-SFS
8-11
(20-28)
2-5
(5-13)
10EC-CIM - -

SAFETY INSTRUCTIONS
Specifications
2
SAFETY INSTRUCTIONS
This equipment should be installed and serviced by technically qualified personnel who are familiar with
the correct selection and use of appropriate tools, equipment, and procedures. Failure to comply with
national and local electrical and plumbing codes and within Little Giant recommendations may result in
electrical shock or fire hazard, unsatisfactory performance, or equipment failure.
Know the product’s application, limitations, and potential hazards. Read and follow instructions carefully to
avoid injury and property damage. Do not disassemble or repair unit unless described in this manual.
Refer to product data plate(s) for additional precautions, operating instructions, and specifications.
Failure to follow installation or operation procedures and all applicable codes may result in the following
hazards:
Risk of death, personal injury, or property damage due to explosion,
fire, or electric shock.
• Do not use to pump flammable, combustible, or explosive fluids such as gasoline, fuel oil, kerosene, etc.
• Do not use in explosive atmospheres or hazardous locations as classified by the NEC, ANSI/NFPA70.
• Do not handle a pump or pump motor with wet hands or when standing on a wet or damp surface, or in water.
• When a pump is in its application, do not touch the motor, pipes, or water until the unit is unplugged or electri-
cally disconnected.
• If the power disconnect is out of sight, lock it in the open position and tag it to prevent unexpected application of
power.
• If the disconnect panel is not accessible, contact the electric company to stop service.
High voltages capable of causing severe injury or death by electrical
shock are present in this unit.
• To reduce risk of electrical shock, disconnect power before working on or around the system. More than one dis-
connect switch may be required to de-energize the equipment before servicing.
• Some pumps are supplied with a grounding conductor and grounding-type attachment plug. To reduce risk of
electric shock, be certain that it is connected only to a properly grounded grounding-type receptacle. Do not
remove the third prong from the plug. The third prong is to ground the pump to help prevent possible electric
shock hazard. Do not use an extension cord.
• Check electrical outlets with a circuit analyzer to ensure power, neutral, and ground wires are properly con-
nected. If not, a qualified, licensed electrician should correct the problem.
• Wire pump system for correct voltages.
• Check local electrical and building codes before installation. The installation must be made in accordance with
their regulations as well as the most recent National Electrical Code (NEC) and the Occupational Safety and
Health Act (OSHA).
• Be sure the electrical connection cannot be reached by rising water. Under no circumstances should the junction
box be located where it may become flooded or submerged by water.
• Do not use the power cord for lifting the pump.
Product specificaties
Merk: | Little Giant |
Categorie: | Waterpomp |
Model: | 6EC-CIM |
Heb je hulp nodig?
Als je hulp nodig hebt met Little Giant 6EC-CIM stel dan hieronder een vraag en andere gebruikers zullen je antwoorden
Handleiding Waterpomp Little Giant
11 Juni 2025
11 Juni 2025
11 Juni 2025
11 Juni 2025
11 Juni 2025
10 Juni 2025
10 Juni 2025
10 Juni 2025
10 Juni 2025
10 Juni 2025
Handleiding Waterpomp
- Silverline
- Reefe
- Sunnydaze Decor
- Daikin
- Hozelock
- Ebara
- Waterco
- Eheim
- Tanaka
- Hitachi
- Grundfos
- Zodiac
- Vonroc
- CMI
- Cotech
Nieuwste handleidingen voor Waterpomp
11 Juni 2025
11 Juni 2025
10 Juni 2025
10 Juni 2025
4 Juni 2025
2 Juni 2025
2 Juni 2025
30 Mei 2025
30 Mei 2025
30 Mei 2025